PR 5500 Instrument Manual
Device Installation
Sartorius EN-83
4.4.7 PR 5500/17 Digital Inputs and Outputs
The plug-in card has 6
passive opto-decoupled inputs
and 8 digital outputs for process control.
GND (-) for all inputs and outputs together.
The card is inserted in the Option 1/FB and/or Option 2 slot.
A max. of 2 PR 5500/17 plug-in cards can be installed!
Internal
connection
Contact strip
Digital inputs
Number
6 (CH1, CH2, CH3, CH4, CH5, CH6)
Voltage
Low: 0…5 V
High: 10…28 V
Passive: external supply required
Current
<
7 mA @ 24 V
<
3 mA @ 12 V
Digital outputs
Number
8 (CH1, CH2, CH3, CH4, CH5, CH6,
CH7, CH8)
Supply voltage
max. 24 V +10% external to plug
Voltage drop
I_Last * 55 ¥ +1 V
(Output, conducting)
Max. switching
current
25 mA
Signals
GND (-) for all inputs and outputs
together
Potential isolation
Yes, via optocoupler
External
connection
2x terminal, 6-pin
2x terminal, 4-pin
Wire gauge max. 1.5 mm
2
Cables
Screened
Connect the cable screen to the
device.
Cable length
max. 50 m
Dimensions
(LxBxH)
52x52x19 mm
Weight
50 g