To ensure the required free moving space of the weighing facility, a maximum of
3 mounting kits with constrainer may be used to constrain a weighing object.
Round containers are the exception (image
①
and
②
). In this case, any number of
constrainers can be installed, provided that they are tangentially aligned.
Special mounting kits are available for weighing points without constrainers.
Alternatively, the constrainer can simply be removed.
With elastic constructions, it may be necessary to deviate from this recommendation
in order to guarantee the weighing object has sufficient stability.
3.2
Internal lift-off protection with integrated jack-up
3.2.1
General instructions
No.
Description
1
Washer (2×)
2
Screw (2×)
3
Centering aid (2×)
4
Nut (2×)
5
Nut (2×)
6
Upper plate
7
Lower plate
The mounting kits are equipped with an internal lift-off protection, i.e. no additional
borings apart from the mounting holes in the vessel foot are required.
The figure shows the position for installation of the load cell.
Mounting kits PR 95T/00, ../01, ../10, ../11
3 Recommendations for installation
EN-6
Minebea Intec