3.2 Technical Data
Protection classes
per DIN EN 60529
IP68, IP69:
Dust-proof and leak-proof against water, with harmful
efects when immersed, (0.5 m water depth, 1,000 h)
and water jets (high pressure and temperature).
IP66:
Dust-proof and leak-proof against strong water jets.
Installation position
Cable entry from below
Quantity of load cells
max. 8
Clamping area screw connection M16
5…9.5 mm
Supply voltage
U
DC
= 24 V
Overvoltage protection
1× 1 AT
Pressure equalization
Stainless steel pressure equalization element
Material of the junction box
High-grade stainless steel 1.4404 (X2CrNiMo17-12-2)
according to EN 10088-3, AISI 316L, JIS SUS316
Surface of the junction box
2R according to DIN EN 10088-2 (cold-rolled, bright
annealed, lat, blank, relective)
Net weight
2.1 kg
Shipping weight
2.3 kg
Service temperature area
-30°C…+80°C
Service temperature area, in explosion-prone area
-20°C…+60°C
Storage temperature range
-30°C…+80°C
Cable screw connections
Metal Ex EMC cable screw connections
Ex-connection values
See Chapter
.
Seal
EMC seal
Cable length
Supply cable PR 6124/xxP for
mains supply PR 6024/62S: max. 200 m
Data cable PR 6124/xxD for device: max. 300 m
Service temperature area of cables
Supply cable PR 6124/xxP: -30°C…+90°C
Data cable PR 6124/xxD: -30°C…+90°C
Cable junction box for digital load cells PR 6024/68S