11.3.3
Middle low ixed open rate (weight)
The open rate of the gate in middle low and the weight are set.
The open rate is a relative value to the full low position at the gate. The setting range of
open rate of the gate is from [0.000 %] to [100.000 %] and the setting range of the
weight is from [0] to [999 999].
[50.000 %] for open rate of the gate, and [1 000] for the weight is set as default.
O
pen
rat
e
[%]
Time [ms]
W
eighing
Time [ms]
Middle Flow
Full Flow
Middle Flow
Full Flow
Note:
-
The open rate is a relative value to the full low position at the gate.
-
In this control method, the gate reaches the open rate set before at once, and is
maintained until the completing time.
1. Select [MEDIUM FLOW] in middle low screen, and select [FIXED OPEN (TIME)], and
then tap [OK].
2. Select [FIXED OPEN (TIME)] in the middle low screen to inputting the each value.
3. Select [TIME], and input the completing time of middle low by ten keys, and then tap
[OK].
4. Select [OPEN], and input the open rate of the gate by ten keys, and then tap [OK].
1. Select [MEDIUM FLOW] in medium low screen, and select [FIXED OPEN (WEIGHT)],
and then tap [OK].
2. Tap [FIXED OPEN (WEIGHT)] in medium low screen to input the each value.
3. Select [WEIGHT], and input the weight that reaches in medium low with ten keys,
and then tap [OK].
4. Select [OPEN], and input the open rate of the gate by ten keys, and then tap [OK].
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-101
Содержание CSD-918 Series
Страница 239: ......