Type 2 AC EV charger Instructions-

 V1.1.0

 

19 

charging immediately. If the car has no S2 switch, when the charger output current is less than 1A 

and  last  for  20min,  the  charger  will  automatically  disconnect  the  output  and  stop  charging.  The 

"green indicator" is always on.   

5.

 

For cars with electronic lock, first needs to press the unlock button on the car to unlock the electronic 

lock. After the retractable rod been withdrawn, the plug could be extracted. Otherwise the plug will 

not be able to pulled out. 

6.

 

After  charging  finished,  disconnect  the  charger  from  the  vehicle  and  place  the  plug  back  into  the 

designated position. 

9.3.2 Charging Interface Instruction 

1. Initialization page 

After the charger is powered on, the screen display system will be initialized. After the initialization, enter the 

default  page  of  the  charger,  as  shown  in  Figure  9.3.2.1/2/3.Meanwhile,  the  charger  panel  "yellow  indicator 

light" is always on.   

 

Figure 9.3.2.1 Initialization Interface 

   

 

Figure 9.3.2.2 Plug and charge mode dispaly                Figure 9.3.2.3 Charge by card mode display 

Содержание HK-D07-230-NE1

Страница 1: ...MINDRA GREEN ENERGY LLP TYPE 2 AC EV CHARGER USERS MANUAL Edition V1 1 0...

Страница 2: ...nformation in this manual to the third party without any authorization To ensure the accuracy the manual has been carefully reviewed If any errors found while using any comments will be welcomed If an...

Страница 3: ...contact the manufacturer timely in case of abnormal situations during the operation Maintenance carried out by other personnel except for professional technicians may cause further damage injuries or...

Страница 4: ...n and Installation Page 9 References Familiar with the charging process Operation instructions Page 16 Inspection and installation Take the charging pile out of the packing box check the product namep...

Страница 5: ...5 3 PROTECTION CHARACTERISTICS 4 5 4 EMC CHARACTERISTICS 5 5 5 SAFETY FEATURES 5 5 6 OTHER CHARACTERISTICS 6 5 7 INDICATOR LIGHT 7 7 DIMENSION AND INSTALLATION 9 7 1 DIMENSIONS 9 7 2 INSTALLATION MET...

Страница 6: ...8 9 3 1 Start Mode Instruction 18 9 3 2 Charging Interface Instruction 19 8 System Remote Upgrading Instruction 23 10 FAULT ALARM AND TREATMENT 24 10 1 FAULT AND RECOVERY 24 10 2 FAULT ALARM AND TREAT...

Страница 7: ...waterproof dustproof and corrosion proof function and have environmental protection design with protection grade of IP 54 The product with modular design concept has integrate the vehicle connector h...

Страница 8: ...t 24 Digital communication between a DC EV charging station and an electric vehicle for control of DC charging IEC 61851 21 2 2018 Electric vehicle conductive charging system Part 1 2 Requirements for...

Страница 9: ...EV control system 4 Environmental Conditions No Item Technical targets Unit Remark Working Transportation Storage 1 Temperature 30 55 40 70 40 70 2 Humidity 5 95 5 95 Condensation free 3 Altitude 2500...

Страница 10: ...0 480 3P N PE 5 AC output frequency range 45 65 Hz Rated frequency 50Hz 60Hz 6 AC output mode 7kW Single phase three wire L N PE 22kW Three phase five wire 3P N PE 5 3 Protection characteristics No It...

Страница 11: ...immunity Level 3 8 Harmonic current emission limit test Grade A 9 Voltage fluctuation and scintillation test Grade A 10 Power terminal conduction disturbance test Grade A 11 Signal port conduct distu...

Страница 12: ...difference module each with 5 times 8 20us impulse wave Maximum discharge current is 40kA Voltage protection level is under 1 8kV 5 6 Other characteristics No Item Technical requirements Unit Remark 1...

Страница 13: ...protection film or anti oxidation treatment 10 Environmental Protection Meet requirements of 2011 65 EU no cadmium hydride and fluoride 5 7 Indicator light No Indicator light Standby Plugged In charg...

Страница 14: ...Charging card management system Support Complete card making and issuing system with asynchronous settlement function Optional 4 Back office monitoring Support Optional 5 Remote upgrading function Sup...

Страница 15: ...nstallation 7 1 Dimensions 1 The outlook of the EV charger is as follows Figure 7 1 1 Outlook of the EV charger Note The above figure shows the appearance of standard models Some customized models hav...

Страница 16: ...imension and size of the EV charger is shown as figure 7 1 2 and chart 7 1 1 Figure 7 1 2 Dimension of the EV charger Chart 7 1 1 Dimension parameters Unit mm Length L Width W Height H EV charger 160...

Страница 17: ...ical surface installed should be smooth and reliable The power line enters from the bottom of the charger side For safe and beautiful use of the charger the power line inletting hole shall be reserved...

Страница 18: ...rger after sale service and maintenance shall be fully considered Note This installation method is for reference only The corresponding installation method shall be selected according to the actual si...

Страница 19: ...allation 40 PVC pipes need to be embedded in advance on the substrate as shown in the picture above 7 2 3 Note This installation method is for reference only The corresponding installation method need...

Страница 20: ...er supply users need to remove the baffle cover of the junction box on the side of the charger and connect the cables of recommended specifications in chart 7 2 3 L N PE in turn according to the conne...

Страница 21: ...Pin Number identification and Function Definition Pin No Identification Rated Voltage and Rated Current Function Definition 1 L1 250V 10A 16A 32A AC power supply single phase 2 L2 480V 16A 32A 63A AC...

Страница 22: ...e contact the manufacturer staff for help Please refer to relevant instruction when operate the charging equipments Pay attention to insertion and extraction force of the vehicle connector to avoid ov...

Страница 23: ...Mode Selection Ensure that charger connected with vehicle correctly Charging completed By Card Swipe the same card for settlement auto full charge Start charging Plug in and charge Start charging End...

Страница 24: ...ct the output and stop charging The green indicator is always on 5 For cars with electronic lock first needs to press the unlock button on the car to unlock the electronic lock After the retractable r...

Страница 25: ...he plug could be extracted Otherwise the plug will not be able to pulled out 6 After charging finished disconnect the charger from the vehicle and place the plug back into the designated position 9 3...

Страница 26: ...e 9 3 2 4 5 below During normal charging process the charger panel green indicator light flashes Figure 9 3 2 4 Plug and charge page Figure 9 3 2 5 Charging by card page 3 Charging Finished Page The c...

Страница 27: ...ault and re plug in before recharging Note Different times of the indicator light flashes stands for different fault types please refer to item 10 2 for details Figure 9 3 2 8 under voltage fault page...

Страница 28: ...th unauthorized card charger will automatically pop up card identification failed as shown in Figure 9 3 2 12 When the countdown is over the screen will jump back to the default interface The user can...

Страница 29: ...ency stop alarm state and the screen will back to the default interface Figure 9 3 2 13 Emergency stop fault page 8 System Remote Upgrading Instruction In system remote upgrade process the charger wil...

Страница 30: ...ing stop of charger may be required Fault code Fault name Flashing times of red indicator light n Treatment 11 Input under voltage 1 Check incoming voltage 12 Input overvoltage 2 Check incoming voltag...

Страница 31: ...uations like severe vibration impact exposure to the sun and rain package dumping etc shall be avoided during the transportation process The loading and unloading operation shall also be paid enough a...

Страница 32: ...er there is deformation and looseness Electrical and Controlling System Inspection Monthly Routine Inspection 1 Good connection between the charger and earth need to be ensured and clear marks need to...

Страница 33: ...ty 5 Security measures must be well improved and insulation shoes must be worn during maintenance operation to avoid personal injury and electric shock NOTICE 1 The company will not be responsible for...

Страница 34: ...hould not press the mechanical button on the charging plug head to avoid the failure of normal charging due to improper insertion of the plug Check whether the mechanical button on the charging plug w...

Страница 35: ...switch inside the charger trips or not If tripping found flip the switch to close the air switch After closing the charger indicator light will be lit again 3 After opening the charger if air switch...

Страница 36: ...Mindra Green energy LLP Address Prasham 102 Devraj Industrial Park Piplaj Pirana Rd Calico Mills Ahmedabad Gujarat 382405 TEL 9157502603 Email support mindrasolar com...

Отзывы: