24
Installation
Connect AC power input to L1 and L2 as shown in Figure 13
and 14 (pages 25 & 26), depending on your power needs.
NOTE:
VFDxx-D230AC series drives are equipped with a
voltage-doubling feature, which converts a 115 VAC input to
a 230 VAC output, for use with 230V motors. The drive
output current rating remains the same. Use caution when
connecting this output.
• If the input voltage is
115 VAC
and the desired output
voltage is 230 VAC (voltage doubler mode), set
115V/230V jumper as shown in Figure 13 (page 25). A
line fuse may be added to L2.
• If the input voltage is
230 VAC
and the desired output
voltage is 230 VAC (no voltage doubler), set 115V/230V
jumper as shown in Figure 14 (page 26). Add a line fuse
to L1 and L2. Do not use the voltage doubler feature with
230 VAC line voltage.
VFDxx-D230AC series
Warning
Do not connect 230 VAC line input when the drive is
set for 115 VAC input. This will result in severe
damage to the motor and drive, and can lead to
explosion and/or injury. Check jumper settings before
connecting AC power input.
Ꮨ