 Open Chassis Microprocessor-based 

Variable Frequency AC Drive 

UPVFD04-D230AC

14300 De La Tour Drive

South Beloit, IL 61080

Phone: (800) 646-2745

Fax: (800) 394-6334

www.minarikdrives.com

Specifications  

......................................................115/230 VAC ± 10%, 50/60 Hz, single phase

......... approx. 2x motor current

......... approx. 4x motor current

..........approx. 2x motor current

...........................................................115/230 VAC, 50/60 Hz, single or three phase

...............................................................................200% (2x) for 1 minute

.............................................................................................16 kHz

............................................................................................0 - 120 Hz

.....................................................30 - 120 Hz

.......................................0 - 50% of maximum

................................................................................0 - 35 VDC

.....................................................................................1 - 12 seconds

.....................................................................................1 - 12 seconds

................................................0 - 5 VDC

....................................................................................>100K ohms

............................................................................................0.5G maximum

..............................................................................................0.1G maximum

.....................................................................................0°C - 40°C

..............................................................................................................................1.4 lbs

AC Line Voltage

AC Line Current 

with 115 VAC line voltage with a 115V motor

AC Line Current

 

with 115 VAC line voltage with a 230V motor

AC Line Current

 

with 230 VAC line voltage with a 230V motor

AC Motor Voltage

Overload Capability

Standard Carrier Frequency

Output Frequency Range

Adjustable Maximum Output Frequency Range

Adjustable Minimum Output Frequency Range

Adjustable DC Injection Voltage

Acceleration Time Range

Deceleration Time Range

Analog Input Voltage Range 

(Signal must be isolated)

Input Impedance (S1 to S2)

Vibration

 (0 - 50 Hz)

                  (>50 Hz)

Ambient Temperature Range

Weight

1/8 - 1/2

1/4 - 1

1/4 - 1

Motor

Horsepower

Range

4.0

Continuous

Motor Current

(Amps) 

115

230

230

Motor

Voltage

(VAC) 

Line

Voltage

(VAC) 

UPVFD04-D230AC

Model

115

115

230

Safety Warnings 

READ ALL SAFETY WARNINGS BEFORE INSTALLING THIS EQUIPMENT 

•  

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

 Have a

  qualified electrical technician install, adjust and service this equipment. Follow the National

  Electrical Code and all other applicable electrical and safety codes, including the provisions of the

  Occupational Safety and Health Act (OSHA), when installed equipment.

•  

Circuit potentials are at 115 or 230 VAC above earth ground

. Avoid direct contact with the printed

  circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a

  non-metallic screwdriver for adjusting the calibration trim pots. Use approved personal protection

  equipment and insulated tools if working on this drive with power applied.

•  Reduce the chance of an electrical fire, shock, or explosion by proper grounding, over-current

  protection, thermal protection, and enclosure. Follow sound maintenance procedures.

• 

 Minarik Drives strongly recommends the installation of a master power switch in the line voltage

  

input.

 The switch contacts should be rated for 250 VAC and 200% of motor nameplate current.

•  

Removing AC line power is the only acceptable method for emergency stopping.

 Do not use

  DC injection braking, decelerating to minimum speed, or coasting to a stop for emergency stopping.

  They may not stop a drive that is malfunctioning. Removing AC line power is the only acceptable

  method for emergency stopping.

•  Line starting and stopping (applying and removing AC line voltage) is recommended for infrequent

  starting and stopping of a drive only. DC injection braking, decelerating to minimum speed, or

  coasting to a stop is recommended for frequent starts and stops. Frequent starting and stopping can

  produce high torque. This may cause damage to motors.

•  

Do not disconnect any of the motor leads from the drive

 unless power is removed or the drive is 

  disabled. Opening any one lead while the drive is running may destroy the drive.

•  Under no circumstances should power and logic level wires be bundled together.

•  Be sure potentiometer tabs do no make contact with the potentiometer enclosure. Grounding the

  input will cause damage to the drive.

•  Caution should be taken when operating fan-cooled motors at low speeds because their fans may

  may not move sufficient air to properly cool the motor. Minarik Drives recommends “inverter-duty”

  motors when the speed range is beyond 10:1.

•  Drive is designed to work with permanent split capacitor, shaded pole, and standard three phase

  induction motors. In general, the drive can work with capacitor-start motors, but it is conditional

  on the current pull when the capacitor is in effect and how long the application calls for a speed that

  

the capacitor will stay in the auxiliary winding. It is recommended to contact the motor manufacturer

  to see if the motor can be ran with a VFD.

ALL DIMENSIONS IN INCH

E

S [MILLIMETER

S] 

Dimensions 

0 1 

.  8 

[  ] 

 0.700  [17.80] 

4.41 [112] 

3.71 [94.2] 

6.90 [17.5] 

DIR

S3

S2

S1

COM

EN

MAX 
 
 
ACCEL 
 
 
BOOST 

   MIN 

TQ/LIM

 

1    2    3    4 

ON 

  SLIP 
COMP 

SW501 

TB501 

MOTOR OUT 

STATUS  LEDS 

3.45 

[87.63] 

N

L1

L2

DEC/BK

Installation 

Mounting

•  Drive components are sensitive to electrostatic discharge. Avoid direct contact with the circuit

•  

board. Hold the drive by the chassis only.

•  Protect the drive from dirt, moisture, and accidental contact.

•  Provide sufficient room for access to the terminal block and calibration trim pots.

•  Mount the drive away from heat sources.  Operate the drive within the specified ambient operating

•  

temperature range.  

•  Prevent loose connections by avoiding excessive vibration of the drive.

•  Mount the drive with its board in either a horizontal or vertical plane. Four 0.20” (5 mm) wide slots

•  

in the chassis accept #8 pan head screws.

•  The heat sink should be earth grounded. Use a star washer beneath the head of at least one of the 

•  

mounting screws to penetrate the anodized heat sink surface and to reach bare metal.

Wiring

Use 18 - 24 AWG wire for logic wiring (COM, DIR, EN, S1, S2, S3).

Use 14 - 16 AWG wire for AC line (L1, L2, N) and motor (U, V, W) wiring.

Shielding Guidelines

As a general rule, Minarik Drives recommends shielding of all conductors. If it is not practical to shield

power conductors, Minarik Drives recommends shielding all logic-level leads. If shielding of logic-level

leads is not practical, the user should twist all logic leads with themselves to minimize induced noise.

Refer to the user’s manual for details on earth grounding shielded wires and filtering.

Fusing

Minarik Drives drives require an external line fuse for protection. Use fast acting fuses rated for 250

VAC or higher and 150% of the maximum line current. Fuse the HOT leg of the AC line when using 115

VAC or both legs when using a 230 VAC line.

Connections 

Line Input

Connect the AC line power leads to terminals L1 and N if using 115 VAC line power or to L1 and L2 if using 230 VAC

line power. Minarik Drives recommends the use of a single-throw, double-pole master power switch. The switch

should be rated at a minimum of 250 VAC and 200% of motor current.

Motor

If using a three phase motor, connect the AC motor leads to terminals U, V, and W. If the motor does not

spin in the desired direction, power down the drive and swap any two of these connections. If using a single

phase motor, connect the AC motor leads to terminals U and V. Refer to the Operations section for

possible wiring setups. 

Speed Potentiometer or Analog Input Signal

Use a 5K - 20K ohm, 1/4 W potentiometer for speed control. Connect the counter-clockwise end of the potentiometer

to S1, the wiper to S2, and the clockwise end to S3. If the potentiometer works inveresly of desired functionality,

(i.e. to increase motor speed, you must turn the potentiometer counterclockwise), power off the drive and swap

the S1 and S3 connections. The drive may also follow a 0-5 VDC analog signal that is isolated from earth ground. Connect

the signal common to terminal S1 and the signal input to terminal S2. To use a PWM signal, use adder card 200-0441.

Direction Switch

If a direction switch is desired, wire a switch to terminals COM and DIR. When the connection is open, the motor will

run in the forward direction. When the connection is closed, the motor will run in reverse. If no direction switch is

desired, leave this connection open.

Enable

Open the terminals COM and EN to coast the motor to minimum speed. Close terminals COM and EN to accelerate the

motor to set speed. If no enable switch is desired, jumper terminals COM and EN. 

Do not use the enable for

emergency stopping.

POWER

LOGIC

115 VAC LINE

DIR

S3

S2

S1

COM

EN

TB501

DIRECTION SWITCH

ENABLE/ DISABLE SWITCH

(open to disable)

10K OHM SPEED
ADJUST POTENTIOMETER

MOTOR

U

V

W

STOP

SWITCH

FUSE

FUSE

STOP

SWITCH

FUSE

230 VAC LINE

OR

N

L1

L2