Minarik AC100 SERIES Скачать руководство пользователя страница 1

Variable Speed AC Motor Drives

EPM Programmer

O

Oppeerraattiioonn  M

Maannuuaall

Содержание AC100 SERIES

Страница 1: ...Variable Speed AC Motor Drives EPM Programmer O Op pe er ra attiio on n M Ma an nu ua all ...

Страница 2: ......

Страница 3: ...IREMENTS 5 4 0 PHYSICAL LAYOUT 5 5 0 USING THE EPM PROGRAMMER 6 5 1 TURNING THE EPM PROGRAMMER ON AND OFF 6 5 2 THE MAIN MENU 8 5 2 1 MASTER TO EPM 9 5 2 2 COMPUTER TO EPM 12 5 2 3 FILE TO EPM 14 5 2 4 EDIT DATA FILE 16 5 2 5 CREATE NEW FILE 21 5 2 6 DELETE DATA FILE 25 5 2 7 LOAD CNFG EEPROM 26 5 2 8 LCD CONTRAST 28 5 2 9 MISC INFORMATION 29 6 0 LCD BACKLIGHT 31 7 0 WARNING MESSAGES TROUBLESHOOTI...

Страница 4: ...e the final determination as to the validity of a warranty claim and sole obligation is to repair or replace only the components which have been rendered defective due to faulty material or workmanship No warranty claim will be accepted for components which have been damaged due to mishandling unauthorized repair and or alteration of the product operation in excess of design specifications or othe...

Страница 5: ...s and distributors welcome the opportunity to assist our customers in applying our products Many customizing options are available to aid in this function Minarik Corporation cannot assume responsibility for any modifications not authorized by its engineering department 3 ...

Страница 6: ... new parameter values are then stored in the User Settings area of the EPM In User mode the user can program and reprogram the drive to suit any application If the drive is programmed to operate according to the OEM Defaults also called OEM mode done by setting Parameter 48 to 02 however the user cannot change the parameter settings stored in the OEM Defaults area of the EPM In this mode the param...

Страница 7: ...the different parts and features of the product 3 0 POWER REQUIREMENTS The EPM Programmer will operate on four 4 D size batteries which are included and already installed in the unit The unit also has a jack for use with an AC power adapter Radio Shack model 273 1454D or equivalent ...

Страница 8: ...s configured for The example version is 309 This display indicates the parameter version of the MASTER EPM if installed The example version is 309 This display indicates the filename of the MASTER EPM if installed The example name is MINARK1_ This display shows the last Main Menu item that was selected The example display is MASTER TO EPM ...

Страница 9: ...he MASTER AND CONFIGURATION PORT This display shows the last Main Menu item that was selected The example display is EDIT DATA FILE Press the OFF key to turn off the EPM Programmer The LCD display will read SHUTDOWN IN 5SEC and the seconds will countdown to 0 at which time the display will go black indicating that the unit is off NOTE If any keys except the OFF key is pressed during SHUTDOWN the c...

Страница 10: ...he EPM Programmer In order to edit a stored data file the configuration version of the EPM Programmer must match the parameter version of the data file CREATE NEW FILE Create a new data file to be stored in the EPM Programmer DELETE DATA FILE Erase a data file that is stored in the EPM Programmer LOAD CNFG EEPROM Load Configuration Version Configures the EPM Programmer to allow editing of data fil...

Страница 11: ...r to Section 2 0 in this manual and the AC100 or AC200 Series Installation and Operation Manual Section 13 2 and Parameter 48 in Section 15 0 for more information on the Electronic Programming Module EPM Follow the procedure below to copy data from the MASTER EPM to the target EPM 1 Install the EPM to be copied in the MASTER AND CONFIGURATION PORT 2 Install the EPM that will receive the data into ...

Страница 12: ... the target EPM will be converted to the same parameter version as the transferred data file which may result in improper drive operation If the parameter version of an EPM does not match the parameter version of the drive it is installed in the drive will display a cF fault and the drive will not operate Refer to the AC100 or AC200 Series Installation and Operation Manual for more information on ...

Страница 13: ...ifferent than the OEM Defaults If a MASTER EPM like this is copied to a target EPM the User Settings are copied to both the User Settings and OEM Defaults area of the target EPM but the data file name is not copied Therefore the file name of the target EPM will appear as follows This display does not indicate a problem with the EPM It simply indicates that the User Settings and OEM Defaults are th...

Страница 14: ... the EPM Programmer to be connected to the computer s serial port using a standard RS 232 serial cable not supplied by Minarik Corporation The TechLink program must be running in EPM MODE and the PROGRAM option must be selected from the PARAMETER drop down menu Follow the procedure below to copy a data file to the TARGET EPM 1 Install the target EPM that will receive the data into the EPM PORT 2 U...

Страница 15: ... the left side of the display If a connection cannot be established the display will read PROGRAMR OFFLINE Check the configuration of the computer and verify proper connections between the EPM Programmer and the computer 4 Use the V and W keys to view the names of the available data files stored in the TechLink folder on the computer Depending on the speed of the computer the display may not read ...

Страница 16: ...et EPM from the EPM PORT The EPM is now fully programmed and ready to be installed in a drive 8 To program another EPM using the same data file simply install another target EPM in the EPM PORT and repeat step 6 NOTE If this procedure is attempted without a target EPM installed in the EPM PORT the display will flash EPM MISSING Press the MENU key to reset the display 5 2 3 FILE TO EPM This functio...

Страница 17: ...s Installation and Operation Manual for more information on the cF fault Follow the procedure below to copy a data file to the target EPM 1 Install the target EPM that will receive the data into the EPM PORT 2 Use the MENU key to scroll to FILE TO EPM 3 Press ENTER The display will show the file name and parameter version number of the last data file that was selected If the file that appears is t...

Страница 18: ...irection NOTE 1 This function requires that the EPM Programmer to be configured for the same parameter version number as the file being edited For example if the EPM Programmer is configured for version 309 it can only edit version 309 data files To edit data files with different parameter versions the EPM Programmer must be configured for the same parameter version using the LOAD CNFG EEPROM func...

Страница 19: ...ata file is found press ENTER to access the items that can be changed within the file A blinking cursor will appear on the left side of the display the first item that can be changed is the data file name To skip the procedure for changing the data file name go to Step 7 4 Press ENTER A solid cursor will appear under the first character of the file name The file name can be up to 8 characters long...

Страница 20: ...e stored in the EPM Programmer already exists with the same name the display will flash NAME EXISTS and a different name must be selected 7 Press the V key to scroll to the next menu item KEYPAD SPEED This sets the initial keypad speed command when the drive parameters are reset to OEM Defaults If the drive parameters are reset to factory defaults the initial keypad speed is always 20 0 Hz Refer t...

Страница 21: ... and return the display to the item menu 10 Press the V key to scroll to the next menu item DIRECTION This sets the initial rotation direction when the drive parameters are reset to OEM Defaults If the drive parameters are reset to factory defaults the initial rotation direction is always forward Refer to Parameter 48 in the AC200 Series Installation and Operation Manual for more information on re...

Страница 22: ...store the value and return the display to the item menu 13 Press the V and W keys to scroll through the next menu items which are the drive parameters The procedure for changing the parameter settings is the same as that for changing the default keypad speed and the rotation direction Refer to the AC100 or AC200 Series Installation and Operation Manual for a complete list and description of the pa...

Страница 23: ...ing data from a computer file the COMPUTER TO EPM function must first be used to download the desired file Refer to Section 5 2 2 NOTE 2 The new file will have the same parameter version as the file that it was created from regardless of the parameter version that the EPM Programmer is configured for However once the new file is created it can only be edited if the configuration version of the EPM...

Страница 24: ...R to store the file name The display will then flash INIT DATA FROM indicating that the source of the initial data for the new file must be chosen NOTE File names cannot be duplicated If a file stored in the EPM Programmer already exists with the same name the display will flash NAME EXISTS and a different name must be selected Use the V and W keys to select a character for each space ...

Страница 25: ...ORT or a computer file created using TechLink software Once the desired data source is selected press ENTER If DATA FILE is selected go to Step 5 If MASTER DATA is selected go to Step 7 If COMPUTER FILE is selected go to Step 8 5 When DATA FILE is selected the display will flash SELECT DATA FILE and the display will show the last data file that was selected If the data file that appears is the des...

Страница 26: ...ted without an EPM installed in the MASTER AND CONFIGURATION PORT the display will flash MASTER MISSING Press MENU to reset the display 8 When COMPUTER FILE is selected the computer file stored in the buffer can be copied to create the new file The file can then be edited using the EDIT DATA FILE function refer to Section 5 2 4 NOTE If the buffer does not contain a data file or the data file is no...

Страница 27: ...ty data files If the EPM Programmer s memory is full and an attempt is made to create a new file the EPM Programmer will display NOT ENOUGH SPACE In this case old or obsolete files would need to be deleted to make space for new files Before deleting files however TechLink requires version 1 12 or newer can be used to save them to disk NOTE If an attempt is made to delete the DEFAULTS data file the...

Страница 28: ...its parameter version cannot be changed and the EPM installed in the drive must have the same parameter version or the drive will not operate Likewise the configuration version of the EPM Programmer must match the parameter version of a data file in order to edit that data file The EPM Programmer can store data files with different parameter versions but can only edit files which match the configu...

Страница 29: ...oad the new configuration NOTE If the EPM installed in the MASTER AND CONFIGURATION PORT is not a Configuration EPM the display will read INVALID CFG DATA 4 Press ENTER to confirm that the new configuration is to be loaded Once the new configuration is loaded data files with the same parameter version can be edited using the EDIT DATA FILE function refer to Section 5 2 4 ...

Страница 30: ...e contrast of the LCD display 1 Use the MENU key to scroll to LCD CONTRAST 2 Press ENTER The display will show the present contrast setting 3 Press ENTER again A blinking cursor will appear on the right side of the display 4 Once the desired contrast setting is found press ENTER to store it Then press the MENU key to go back to the MAIN MENU Use the V and W keys to select the desired contrast sett...

Страница 31: ... a new main circuit board in the EPM Programmer A blinking cursor appears on the left side of the display 3 Use the V and W keys to scroll through the items Using the V key the next item is the configuration version This can be changed using the LOAD CNFG EEPROM function refer to Section 5 2 7 This version number must match the parameter version number of a data file in order to edit the data file...

Страница 32: ... the V key the last item is the password The factory default password is 0000 If the password is set to a value other than 0000 the password function is enabled To change the password press the ENTER key to shift the cursor to the right side of the display Use the V and W keys to scroll to the desired password value Press the ENTER key to store the value and shift the cursor back to the left Once ...

Страница 33: ...d in previous sections at points in the procedure where the message may appear The table is continued on the next page WARNING MESSAGES MESSAGE DESCRIPTION CONFIG INVALID Will appear in the MISC INFORMATION function if the configuration data in the EPM Programmer is corrupted Data files cannot be edited in this state EPM MISSING Attempted to transfer data to the EPM PORT without an EPM installed E...

Страница 34: ...e buffer and a file was not downloaded from the computer NOT ENOUGH SPACE There is not enough memory to store another data file NO VALID FILES Attempted COMPUTER TO EPM function and the EPM Programmer could not establish communications with the computer PROGRAMR OFFLINE Attempted COMPUTER TO EPM function and the EPM Programmer could not establish communications with the computer READ ONLY FILE An ...

Страница 35: ...33 Notes ...

Страница 36: ...Notes ...

Страница 37: ...Notes ...

Страница 38: ...rik Corporation 901 E Thompson Avenue Glendale CA 91201 2011 Sales 800 646 2745 FAX 800 394 6334 www minarikcorp com Document Number 250 0299 Rev 0 Printed in the U S A 11 00 U S A 10 00 Outside U S A 11 00 ...

Отзывы: