- 3-3 -
In Case Defective Printing is not Recovered [STATION]
When the station interior is severely contaminated or defective printing is not recovered
after operating the head cleaning function (
P. 2-29), clean the suction nozzle and the
caps using the cleaning kit as follows,
Washing liquid (SPC-0385), Gloves, Cleaning swab (SPC-0386), Goggles
• Be sure to wear the supplied goggles and the gloves during cleaning, or
you may get the ink in your eyes.
• Do not move the carriage out of the capping station by hand. Use the
appropriate operation key to move the carriage.
Cleaning the interior of the station
1.
Touch the [FUNCTION] in the LOCAL
mode.
2.
Touch the JOG [ ] or [ ] to select the
[MAINTENANCE].
3.
Touch the [ENTER].
4.
Touch the JOG [ ] or [ ] to select
the [STATION].
5.
Touch the [ENTER].
6.
Touch the [ENTER].
The carriage moves on the table.
STATION
CARRIAGE OUT
: ent
MAINTENANCE
STATION
< ent >
MAINTENANCE
LIST
< ent >
FUNCTION
MAINTENANCE
< ENT >
FUNCTION
DATA CLEAR
< ENT >