© 2013 MIMAKI ENGINEERING CO.,LTD.
5.1.8
P.1
R.1.0
MAINTENANCE MANUAL > Test Items > Test Function > AGING
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
1.0
Remark
1.0
5.1.8 AGING
Outline
For the durability testing, continuous reciprocating operation is executed.
List of AGING items
*It may cause ink leakage from the Head when executed in keeping the ink charged.
Name of Test
Function
XY SERVO*
Continuous reciprocating operation in X-axis and Y-axis
X SERVO
Continuous reciprocating operation in X-axis
Y SERVO*
Continuous reciprocating operation in Y-axis
PUMP MOTOR
Continuous operation of Ink-supplying Pump Motor (Max. 24days)
WIPER MOTER
Continuous reciprocating operation of Wiper Motor (Max.9999Times)
WIPE HEAD
Continuous reciprocating operation of Wiping. (Max.9999Times)
CAPPING
Continuous reciprocating operation of Capping.
CLEANING
Execution of cleaning operation by the designated times (Max.500Times)
FLASHING
Continuous reciprocating operation of Flashing.
X measure
Continuous operation of the X measure.
COM
For developmental debugging
INK SUPPLY
Operation of Ink-supplying Pump Motor.
For the work, put down unused media or the like in advance since it may cause ink leakage when
[Y SERVO] or [XY SERVO] is executed.