4-8
Chapter 4 Installation
Connection of water supply and discharge
In order to operate the belt cleaning unit properly, it is necessary to properly connect the tube with the inner diameter of 16
mm to the solenoid valve.
In case of washing water discharge, before starting this machine, make sure that the washing water drain pipe is properly
connected and water can be discharged properly.
At the bottom of the tank area there is a discharge valve to open and close the tank drain.
Ground connection
Grounding of the steel structure is ensured by an insulated wire connected to the terminal block of the electrical box and
the earth bar.
In the user system, ground protection of all parts of the plant and all equipment circuits must be done by connecting the
parts to individual grounding systems.
Make the wiring to the main grounding connection as short as possible so that the grounding conductor is not exposed to
the risk of mechanical stress or corrosion.
Make the connection to the main grounding connection as short as possible and make sure that grounding conductors are
not subjected to mechanical stress or danger of corrosion.
In order to ensure the safety of people and equipment, it is necessary to observe the following rules.
• Make sure the power supply characteristics are compatible with the technical characteristics of the equipment.
• Connect the power and connecting cables firmly and correctly to the corresponding terminals on the machine.
Connect the shield of the cable to the grounding system above.
Storage Condition
Parts (pin rollers, guide rails, machined parts, etc.) that are subject to oxidation risk at the time of shipment are properly
protected with grease or protective spray.
For short-term storage, place it in a dry place to protect it from moisture and check that the packaging is not damaged or
completely dry. Do not remove protection applied to various connections.
In case of long-term storage, take additional preventive measures besides the above mentioned method. In fact, it is
necessary to repair the lubricated protective layer of all parts which is at risk of oxidation.
To ensure the integrity and functionality of electro circuits and electronic circuits, periodically replace the silica gel
according to the moisture content that is present.
The cross section S [mm
2
] of the phase
conductor of the machine
Minimum cross section of protective
earth conductor Sp [mm
2
]
S
≦
10
Sp=S
16<S
≦
35
Sp=16
S>35
Sp=S/2
Water feeding device
Exhaust exclusion valve
Water drain
Содержание ML Tiger-1800B MKII
Страница 3: ...ii 1 2 2 4 5 6 ...
Страница 6: ...v Troubleshooting 9 5 Dismantling 9 27 ...
Страница 25: ...Chapter 1 Introduction 1 19 1 2 3 4 5 6 M915601 PC outlet rated label ...
Страница 26: ...Chapter 1 Introduction 1 20 ...
Страница 38: ...2 12 Chapter 2 Outline explanation ...
Страница 50: ...4 10 Chapter 4 Installation ...
Страница 120: ...Chapter 6 Basic usage 6 66 ...
Страница 140: ...Chapter 7 Operation Adjustment and Maintenance 7 20 ...
Страница 174: ... MIMAKI ENGINEERING CO LTD 2020 IG MM Tiger Products Install Pack 2 04 ...