- 1.19 -
Connecting the power cable
Connect the power cable to the receptacle of the following specifications.
•
Voltage
:
AC 100 - 240 V
±
10%
•
Frequency :
50/60 Hz
±
1%
•
Capacity
:
5 A or more (500 W or more)
• Be sure to turn off the power switch of the plotter in prior to the connection of
the power cable.
• Be sure to insert the power cable into an approriately-grounded receptacle.
If not, there is a fear of arising electric shock hazards and damage to the
plotter.
• Use a outlet which power breaker applicable to the 50A, and 0.01 seconds or
above.
STEPS:
1.
Connect the power cable to the AC inlet.
Configuration of power cable
2.
Connect the power cable to the 3-pole recep
tacle.
For a 2-pole receptacle, connect the ground-
ing adapter supplied with the plotter to the
power cable plug. Properly ground the green
wire (ground lead) of the grounding adapter.