Mi453

Reducing Sugars

Reducing Sugars

Reducing Sugars

Reducing Sugars

Reducing Sugars

INSTRUCTION MANUAL

Содержание Mi453

Страница 1: ...ukee W Milwaukee W Milwaukee W Milwaukee W Milwaukee Wine L ine L ine L ine L ine Lab Photometer ab Photometer ab Photometer ab Photometer ab Photometer Mi453 Reducing Sugars Reducing Sugars Reducing...

Страница 2: ...er for wine analysis 2 2 2 2 2 FUNCTIONAL DESCRIPTION 3 GENERAL DESCRIPTION 4 SPECIFICATIONS 6 GUIDE TO DISPLAY CODES 7 GENERALTIPSFORANACCURATEMEASUREMENT 8 MEASURENTPROCEDURE 9 ERRORMESSAGES 13 BATT...

Страница 3: ...R ON AND OFF E ZERO KEY TO START THE ZERO MEASUREMENT F READ KEY TO START THE SAMPLE MEASUREMENT G TIMER KEY TO ACTIVATE THE COUNTDOWN MODE TIMER DISPLAY A BATTERY STATUS ICON B HOURGLASS ICON C LAMP...

Страница 4: ...ion of grapes can help to decide when to start harvest Having the highest possible sugar content is important because this is the main parameter that defines the commercial value of grapes During the...

Страница 5: ...00 PL automatic pipette Two plastic tips for 1000 PL automatic pipette One spoon One funnel Filter paper 25 pcs Four 1 5V AA batteries Tissue for wiping cuvets Instruction Manual Instrument Quality Ce...

Страница 6: ...ocell with narrow band interference filter 610 nm Method Fehling Method Environment 0 to 50 C 32 to 122 F max 95 RH non condensing Battery Type 4 x 1 5 volt AA batteries Auto Shut off After 15 of non...

Страница 7: ...e timer is finished Indicates that the instrument is in a ready state and waiting for the next command Timer or Zero This prompt indicates the battery capacity value This prompt appears for a few seco...

Страница 8: ...tic pipettes please follow the related Instruction Sheet All the reaction times reported in this manual are referred to 20 C 68 F As a general rule of thumb they should be doubled at 10 C 50 F and hal...

Страница 9: ...To remove interference of phenols samples of Red Wine must be treated with activated carbon Fill one cuvet with 10 mL of Red Wine Add 2 spoons of Mi553 0 Charcoal to the cuvet Cap the cuvet and mix v...

Страница 10: ...ith water Remove the cap from two vials Mi553A 0 RS reagent A Use the Mi0024 1000 L automatic pipette to add exactly 1 mL of Mi553B 0 RS reagent B to each vial For a correct use of the automatic pipet...

Страница 11: ...d then press TIMER to activate a 7 minutes countdown At the end of the digestion period switch off the reactor place the vials carefully in the test tube rack and wait for 10 minutes Warning as the vi...

Страница 12: ...nk Vial Insert the Sample Vial into the instrument Note Do not shake or invert the Sample Vial anymore otherwise the samples may become turbid Press READ and the display will show during measurement T...

Страница 13: ...nt Please dilute the sample five times see General tips for an accurate measurement page 8 Note To convert the Reducing Sugars concentration from g L to multiply the reading by 0 1 e g 12 5 g L x 0 1...

Страница 14: ...attery cover from the bottom of the instrument and change the old batteries with 4 fresh 1 5V batteries paying attention to the correct polarity Replace the cover on sample reading A flashing value of...

Страница 15: ...t covered by the warranty Milwaukee Martini instruments reserves the right to make improvements in design construction and appearance of its products without advance notice For your Safety don t use o...

Страница 16: ...s kik t sor 11 6726 Szeged Hungary Tel 36 62 428 050 Fax 36 62 428 051 e mail sales milwaukeeinst com Milwaukee Instruments Inc 2950 Business Park Drive Rocky Mount NC 27804 USA Tel 1 252 443 3630 Fax...