Страница 1: ...1 DL510 BLACK BOX DATA LOGGING CONTROLLER ORP Temperature Set Up Operation Manual Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Страница 2: ...le Wi Fi Settings Wi Fi Enable Security Type Network Name SSID Pre shared Key View Device IP Upload Interval Portal Sync Portal Service Exit Wi Fi Security Open WEP WPA Exit Wi Fi Settings Wi Fi Enable Security Type Network Name SSID Pre shared Key View Device IP Upload Interval Portal Sync Portal Service Exit Network Name XXXXXXXXXXXXX Wi Fi Settings Wi Fi Enable Security Type Network Name SSID P...

Страница 3: ...always be displaying Primary Display Screen On the menu screens only four lines will be visible at a time To see more options scroll the list by using up down arrows on the keypad When the cursor appears beside the appropriate function or setting press SELECT THE KEYPAD Pressing the Menu button brings up a screen featuring the full menu At the bottom of all menu screens there will be an Exit optio...

Страница 4: ...s SELECT 8 Again work across the Hours Minutes 00 00 using left right arrows picking the number you want to change then using up down arrows to select the appropriate number Note that this unit displays in military time 24 hour there is no am pm option that is 9AM is 09 00 and 2 05PM is 14 05 10 30PM is 22 30 9 Once complete press SELECT to enter the new time A screen will appear indicating that y...

Страница 5: ...0 750 Critical Caution Setpoint Caution Critical Red Lime Blue Lime Red Below Alert Above Alert If the value for ORP is within the parameters you have set the status lights on both sides of the screen will remain blue If the blue changes to lime this signals that the ORP value has reached the Caution level If the value continues to drift further from the setpoint and reaches the Critical level the...

Страница 6: ... Data Logger screen with the cursor beside Start Time 4 Press SELECT to advance to the Start Time screen Using the keypad arrows enter the start time and press SELECT to save 5 Press the Menu button to return to the primary display screen Note To capture a real time reading press the Snap Shot button A snap shot will not interfere with scheduled data logging When you press the Snap Shot button on ...

Страница 7: ...leted selection of days press SELECT and this information will be SAVED Menu Button IDC Setup Sessions Day The DL510 will space sessions evenly over the available time Start Time to End Time on each day 1 Press Menu button scroll down to IDC Setup and press SELECT 2 Place cursor beside Sessions Day and press SELECT 3 Use the left right arrows to move the blinking cursor across the three digits In ...

Страница 8: ...ad Please enter valid Start and End Times You will need to add more time between Start and End Times if possible or make adjustments in Session Time and or Sessions Day Menu Button IDC Setup Flow Calibration When utilizing the IDC to dispense a solution you must determine how long your pump needs to be on to provide a given volume of solution Since pump efficiency solution strength and viscosity t...

Страница 9: ...7 ...

Страница 10: ...8 ...

Страница 11: ...9 ...

Страница 12: ... two banks 64KB and 32KB Flash Memory 512 KB Data Retention 100 years at 25 C Station and Access Point Wi Fi 802 11 b g n Roles with Integrated Radio Baseband and MAC TCP IP Embedded TCP IP stack Circuit Board Protection RJ45 Back Feed Protection with Short Circuit Protection GLP Ground Loop Prevention Dual Ground Loop Prevention Circuit and Chipset Input Power Supply 7V to 12VDC Recommended Inter...