49 |
P a g e
Version 2.3 (05/2021) EN
User Manual for SEIT 500
Protective and warning fields can be switched and muted according to speed and task that SEIT 500
executes. For example
; Figure 5.24
,
Figure 5.25, Figure 5.26
and
Figure 5.27
represent field sets related
with the speed sets of SEIT 500.
Each speed set has a specific protective and warning fields, and these fields has different dimensions for
each speed set.
Figure 5.23:
Demonstration of field sets’ distance
Table 5.4: Distances according to speeds and field
Distance
Field
High Speed
(mm)
Medium
Speed (mm)
Low Speed
(mm)
Stopping
(mm)
Distance 1
Protective Field
1020
400
270
130
Warning Field 1
1500
1460
610
400
Warning Field 2
2500
1500
1000
600
Distance 2
Protective Field
1200
1060
1020
900
Warning Field 1
1200
1120
1170
1100
Warning Field 2
1260
1160
1170
1240