Milnor MWR12J5 Скачать руководство пользователя страница 1

Published Manual Number/ECN: ME7MJR11AE/2021046A

•  Publishing System: TPAS2
•  Access date: 01/22/2021
•  Document ECNs: Latest

Schematic/Electrical Parts

Milnor® Washer-Extractor

MWR/T12J5, MWR/T16J5,

MWR/T18J4,

MWR/T18J6, MWR/T27J5

PELLERIN MILNOR CORPORATION

POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.

Содержание MWR12J5

Страница 1: ...Publishing System TPAS2 Access date 01 22 2021 Document ECNs Latest Schematic Electrical Parts Milnor Washer Extractor MWR T12J5 MWR T16J5 MWR T18J4 MWR T18J6 MWR T27J5 PELLERIN MILNOR CORPORATION POST OFFICE BOX 400 KENNER LOUISIANA 70063 0400 U S A ...

Страница 2: ......

Страница 3: ...Diagrams BIUUUK01 20130308 18 Sample Schematic BMP010012 2018343 20 3 Phase Motor Connection Diagram BMP850029 1999362B 21 3P Motor Diagram Multivolt W80008 2001253A 22 Board to Board Wiring W7MJRBW 2012462B 24 Flushing Supplies W7MJRCF 2007354B 26 Electrical Valves W7MJREV 2007354B 28 Microprocessor Inputs W7MJRIA 2014303B 30 Control Circuit Transformer W7MJRLV 2017365B 32 Start Circuit W7MJRS 20...

Страница 4: ......

Страница 5: ... FUSE HV FEED TRANSFORMER PRIMARY W7MJRLV 09FF003AWV FUSE BUSS STYLE CC TYPE FNQ R 3 AMP 60 CONTROL PANEL EM ELECTROMAGNET AND SOLENOID EMDL SOLENOID DOOR UNLOCK W7MJRS 09K063C24 DOOR LOCK SOLENOID 24V DOOR LATCH EMDR SOLENOID DRAIN VALVE W7MJREV 96D35RAA71 DRAINVAL RT ANG 3 240V 50 60C BELOW SHELL ES POWER SUPPLY ELECTRONIC ESPS POWER SUPPLY MICROPROCESSOR W7MJRBW 98CMCR1825 PWRSP 5 12 12V 85 264...

Страница 6: ... SW HIGH WATER LEVEL W7MJRIA 09N086A PRESS SWITCH EATON 738 761 CONTROL PANEL SPLL PRESSURE SW LOW WATER LEVEL W7MJRIA 09N086A PRESS SWITCH EATON 738 761 CONTROL PANEL TP TEMPERATURE PROBE TP PROBE TEMPERATURE W7MJRBW 98CMCR3605 ELECTRIC HEATER PROBE CONTROL PANEL VE VALVE ELECTRIC OPERATED VEC1 VALVE FLUSH DETERGENT W7MJRCF MESSAGE MS CHEMICAL FLUSHING VALVE BY OTHERS SUPPLY INJECT VEC2 VALVE FLU...

Страница 7: ...ical attack are not covered by this warranty For parts which require routine replacement due to normal wear such as gaskets contact points brake and clutch linings belts hoses and similar parts the warranty time period is 90 days We reserve the right to make changes in the design and or construction of our equipment including purchased components without obligation to change any equipment previous...

Страница 8: ...ou can also get components from the Milnor factory Tell the supplier the machine model and serial number and this data for each necessary component The component number from this manual The component name if known The necessary quantity The necessary transportation requirements If the component is an electrical component give the schematic number if known If the component is a motor or an electric...

Страница 9: ...lies to a subset of machines will normally state in the title which models and or options it covers Compare this with the nameplate on your machine and with your purchase records Each schematic is devoted to circuits with common functions e g microprocessor inputs motor contactors Schematics appear in the manual in alphanumeric order 1 Component Prefix Classifications and Descriptions Component it...

Страница 10: ...whose contacts switch immediately when voltage is applied to its coil and revert to normal when the voltage is removed Figure 4 Standard Relay CR Coils and Contacts Legend A Coil B Contacts CP Control Photo Eye Figure 5 Photo eyes sense the presence of an object without direct physical contact Photo eyes consist of a transmitter receiver and output module These components may be housed in one asse...

Страница 11: ...c Fuse Figure 6 A fuse is an over current safety device with a circuit opening fusible member which is heated and severed by the passage of over current through it EL Electric Light Figure 6 Indicator lights may be either incandescent or fluorescent EM Electro Magnet Solenoid A device consisting of a core surrounded by a wire coil through which an electric current is passed While current is flowin...

Страница 12: ...al energy Figure 8 Transformer EX Figure 9 Electric Motor MR MV Motor Variable Speed Inverter To vary the speed of an AC motor the volts to frequency ratio must be kept constant The motor will overheat if this ratio is not maintained The motor variable speed inverter converts three phase AC to DC The inverter then uses this DC voltage to generate AC at the proper voltage and frequency for the comm...

Страница 13: ...y operated e g Start button Master switch etc Figure 11 Cam Switch SC Figure 12 Hand Operated Switch SH SK Switch Key Lock Figure 13 A switch that requires a key to operate This prevents unauthorized personnel from gaining access to certain functions e g the Program menu SL Switch Level Operated Figure 14 A switch connected to a float that causes the switch to open and close as the level changes F...

Страница 14: ...ble set points e g Motometers or Combistats TB Terminal Board Figure 18 A strip or block for attaching or terminating wires Figure 17 Temperature Switch ST Figure 18 Terminal Board TB VE Valve Electric Operated Figure 19 A valve operated by an electric coil to control the flow of fluid The fluid can be air water or hydraulic Figure 19 Electrically Operated Valve VE ZF Rectifier Figure 20 A solid s...

Страница 15: ...n electronic circuit or piece of equipment Connectors are male or female according to whether they plug into or receive the mating connector 2 Component Terminal Numbering CAUTION 1 Risk of Mis wiring Due to electrical component manufacturing inconsistencies the pin numbers imprinted on components such as connectors and relay bases used on Milnor machines often do not correspond to the pin numbers...

Страница 16: ...RIN MILNOR CORPORATION Figure 22 Plug in Relays 11 pin Relay with Grey Base Legend 14 pin Relay with Grey Base older 14 pin Relay with Black Base newer 14 pin Relay with Beige Base rare Left View of relay and base Right Same view show ing pin num bers 12 ...

Страница 17: ...ng with the letter M e g CRxxM are not discrete components but are a component of a printed circuit board They are usually not individually replaceable Figure 23 AMP Connector Pin Locations 36 pin Connector 18 pin Connector Legend A View of mating halves of connector B Same view showing assigned pin numbers 13 ...

Страница 18: ...agrams PELLERIN MILNOR CORPORATION Figure 24 Molex Connector Pin Locations 15 pin Connector 9 pin Connector 6 pin Connector 4 Pin Connector 2 pin Connector Legend A View of mating halves of connector B Same view showing assigned pin numbers 14 ...

Страница 19: ...inal R if normally open terminal L if normally closed L Terminal S if normally open terminal M if normally closed 3 Features of Milnor Electrical Schematic Diagrams Document BMP010012 following this section is a sample schematic based on a schematic diagram for the Milnor gas dryer For the purposes of this exercise the schematic is shown gray and explanations of the items on the schematic are show...

Страница 20: ...ain several different types of circuit boards and one or more boards of each type A numerical suffix identifies the board type and a numerical prefix identifies which one of several boards of a given type is being depicted For example the designation 1MTA5 identifies this as the first I O board 8 output 16 input board in the control system As shown on the drawing a pin number follows the board num...

Страница 21: ...This page intentionally left blank 17 ...

Страница 22: ... Main Air Any relay that ends with an M is located on an electronic board S 09 S 11 S 11 Normally open contacts Normally closed contacts 7 1 contact 8 2 contact 9 3 contact V K contact 7 4 contact 8 5 contact 9 6 contact V Q contact Contact not used Drawing and line where contact is located 1 2 3 4 BMP010012 left 2018343 7 1MTA5 6 Pin number Board MTA group designation Mass termination assembly MT...

Страница 23: ...ble Page line numbers Major revision letter Page number S Machine type Gas fired dryer 6th generation of controls W Wiring Class of control system Title of this circuit Voltage of this circuit 4 This indicates on which page W6DRYGS and line number 08 the relay coil can be found for this set of contacts BMP010012 right 2018343 19 ...

Страница 24: ...20 ...

Страница 25: ...21 ...

Страница 26: ...22 ...

Страница 27: ...23 ...

Страница 28: ...24 ...

Страница 29: ...25 ...

Страница 30: ...26 ...

Страница 31: ...27 ...

Страница 32: ...28 ...

Страница 33: ...29 ...

Страница 34: ...30 ...

Страница 35: ...31 ...

Страница 36: ...32 ...

Страница 37: ...33 ...

Страница 38: ...34 ...

Страница 39: ...35 ...

Отзывы: