General—

Operating and

Troubleshooting

Washer-extractors with

the E-P OneTouch

®

Controller

PELLERIN MILNOR CORPORATION  

POST OFFICE BOX 400, KENNER, LOUISIANA 70063 - 0400, U.S.A.

Содержание MWR09E5 Series

Страница 1: ...23 Access Date 20060823 Custom n a Applicability CEP Language Code ENG01 Purpose publication Format 1colA General Operating and Troubleshooting Washer extractors with the E P OneTouch Controller PELLERIN MILNOR CORPORATION POST OFFICE BOX 400 KENNER LOUISIANA 70063 0400 U S A ...

Страница 2: ...Applicable Milnor products by model number MWR09E5 MWR18E4 ...

Страница 3: ...ual and its Included Documents Document BIUUUD13 A complete identification of this manual or any document in this manual must include all specifications shown on the front cover as defined below Published manual number Primary identification number for the manual or any variation of it Specified date The approximate date of introduction of the product or product change this manual covers As of dat...

Страница 4: ...question should be your authorized Milnor dealer but problems or special situations encountered in the field may require consultation with the Milnor factory Written correspondence can be mailed to this address Pellerin Milnor Corporation Post Office Box 400 Kenner Louisiana 70063 0400 Telephone 504 467 9591 http www milnor com ii 1 Ordering Replacement Parts In most cases your authorized Milnor d...

Страница 5: ...er please contact our warranty group Milnor Warranty Administrator Telephone 504 712 7735 Fax 504 469 9777 E mail service milnor com Attention Warranty ii 4 Equipment Manuals If you have suggestions or questions about any part of this manual or any other documentation included with your machine the Milnor technical publications group can assist you Milnor Technical Publications Telephone 504 712 7...

Страница 6: ...ller 1 2 About the Forces Transmitted by Washer extractors Document BIWUUI02 1 2 1 Foundation Considerations 1 2 2 How Strong and Rigid Figure 1 How Rotating Forces Act on the Foundation 1 3 Important Instructions for Pumped Chemical Inlets Document BIWUUI01 1 3 1 How Pumped Chemical Systems can Internally Damage the Washer extractor Supplement 1 Preventing Dribbling by Purging Chemical Lines 1 3 ...

Страница 7: ...Position 2 Cold final rinse 2 1 2 3 Positions 3 through 6 not used 2 1 2 4 Position 7 Normal operation 2 1 2 5 Position 8 Normal operation 2 1 3 Configuration Decisions for Machines with Controller 08BT168BT Table 8 Controller 08BT168BT Summary of Configuration Decisions 2 1 3 1 Position 1 Configure for hospitality 2 1 3 2 Position 2 Use Bed and Bath Linen formulas 2 1 3 3 Position 3 Use cold wate...

Страница 8: ...ening the Door during a Formula 3 3 1 3 Unload the Machine 3 3 2 How to End a Formula Early Chapter 4 Testing and Troubleshooting 4 1 Troubleshooting Errors Document BICEUT03 4 1 1 Vibration Switch Tripped 4 1 2 Door Open 4 1 3 Door Inverter Fault 4 2 Testing MWR_ Washer extractors Document BICEPT02 4 2 1 Testing without the Display Kit Chart 1 Operating Sequence Part 1 Chart 2 Operating Sequence ...

Страница 9: ...or Hotel and Hospitality Set 1 Formula C Table 15 Events for Hotel and Hospitality Set 1 Formula D 4 3 1 2 Formula Set 2 Table 16 Events for Hotel and Hospitality Set 2 Formula A Table 17 Events for Hotel and Hospitality Set 2 Formula B Table 18 Events for Hotel and Hospitality Set 2 Formula C Table 19 Events for Hotel and Hospitality Set 2 Formula D 4 3 2 Healthcare Software 4 3 2 1 Formula Set 1...

Страница 10: ... 32 Events for Hotel and Hospitality Set 2 Formula A Table 33 Events for Hotel and Hospitality Set 2 Formula B Table 34 Events for Hotel and Hospitality Set 2 Formula C Table 35 Events for Hotel and Hospitality Set 2 Formula D 4 4 2 Healthcare Software 4 4 2 1 Formula Set 1 Table 36 Events for Healthcare Set 1 Formula A Table 37 Events for Healthcare Set 1 Formula B Table 38 Events for Healthcare ...

Страница 11: ... is first placed in service and after replacing the microprocessor controller Configure this machine by setting DIP switch SW1 on the microprocessor controller See Section 2 1 Configuring E P OneTouch Washer extractor Models in this manual for the location of detailed configuration instructions End of BICEUK02 BIWUUI02 Published Book specs Dates 20060823 20060823 20060823 Lang ENG01 Applic CEP 1 2...

Страница 12: ...w 1 2 2 How Strong and Rigid Many building codes in the U S A specify that laundry floors must have a minimum live load capacity of 150 pounds per square foot 732 kilograms per square meter However even compliance with this or any other standard does not necessarily guarantee sufficient rigidity In any event it is the sole responsibility of the owner user to assure that the floor and or any other ...

Страница 13: ...ribble concentrated chemicals out of the injection tubes when the system is not used for relatively long periods of time as after working hours and during weekends This puts highly concentrated corrosive chemicals in direct contact with dry stainless steel surfaces and often directly on any textiles left in the machine Chemical deterioration rusting of the stainless steel and damage to the textile...

Страница 14: ... of Chemical Tubing Note 1 As shown in Figure 2 all tanks pumps and tubing must be lower than the injection point on the machine and must not dribble chemicals into the machine nor leak chemicals externally onto any portion of the machine or its surroundings 1 3 3 Preventing Leaks Which Can Injure Personnel and Cause External Damage Any ports on the inlet are plugged at the Milnor factory When rep...

Страница 15: ...at chemicals travel to the machine at an upward angle CAUTION 4 Avoid explosions Certain chemicals will react chemically when combined Consult with your chemical supplier representative about the safe use of chemicals Connect chemical tubing so that bleach and sour inlets are as far apart as possible Figure 3 Rear mounted Water and Liquid Supply Injector Figure Legend 1 Assembly for 36 and 42 inch...

Страница 16: ...injection times Use two pumps or valves to inject a small or large quantity of the same chemical if required Supplement 2 Maximizing Chemical Injection Precision Injection of a consistent amount of chemical is important in controlling wash quality and using chemicals economically When chemicals are injected by units of time as is done with most washer extractors injections of short duration can be...

Страница 17: ...igned and connected to a flushing water source CAUTION 9 Component Damage Hazard Board components will burn out and require board replacement if devices driven by inject signals do not meet the above electrical specifications Pumps usually draw a higher current than specified above and will cause board damage This machine provides signals for three chemicals and a manifold flush Table 3 contains t...

Страница 18: ...d and the stopped timers resume counting When the timer in a machine is stopped the current formula event continues until the timer resumes counting If water valves are open when the timer stops they will close when the desired level is reached Chemical injection signals will stop after the designated time but the manifold flush signal will not occur until the timer starts All other actions cylind...

Страница 19: ...ons Your machine was shipped from the Milnor factory with the chip set specified when the machine was ordered Contact the factory to purchase the chip necessary to change the machine from one industry to another For machines using controller board 08BT168BT all formulas are stored in the supplied controller board but only one set is available to the user The available set is determined by the mach...

Страница 20: ... H High 2 H High Drain 1 25 1 25 1 25 Extract 1 1 1 Coast 1 25 1 25 1 25 Rinse 2 2 S High 2 S High Drain 1 25 1 25 1 25 Extract 1 1 1 Coast 1 25 1 25 1 25 Bath 4 F C Low 4 F C Low 4 F C Low 4 F C Low Note A DIP switch setting allows configuring this operation for split fill Drain 1 25 1 25 1 25 1 25 Extract 7 6 7 7 Coast 1 25 1 25 1 25 1 25 Run Time 29 25 34 75 41 0 47 25 Key to Abbreviations D Us...

Страница 21: ...5 1 25 1 25 Bath 7 B H Low Drain 1 25 Rinse 2 S High 2 S High 2 S High 2 S High Drain 1 25 1 25 1 25 1 25 Extract 1 1 Coast 1 25 1 25 Rinse 2 S High 2 S High Drain 1 25 Bath 4 F C Low 4 F C Low 4 F C Low Note A DIP switch setting allows configuring this operation for split fill Drain 1 25 1 25 1 25 1 25 Extract 2 5 2 5 7 7 Coast 1 25 1 25 1 25 1 25 Run Time 26 75 35 0 44 75 50 25 Key to Abbreviati...

Страница 22: ... High 2 H High Drain 1 25 1 25 1 25 Bath 7 B H Low 7 B H Low 7 B H Low Drain 1 25 1 25 1 25 Rinse 2 S High 2 S High 2 S High Drain 1 25 1 25 1 25 Rinse 2 S High 2 S High 2 S High Drain 1 25 1 25 1 25 Bath 4 F C Low 4 F C Low 4 F C Low 4 F C Low Note A DIP switch setting allows configuring this operation for split fill Drain 1 25 1 25 1 25 1 25 Extract 7 6 7 7 Coast 1 25 1 25 1 25 1 25 Run Time 29 ...

Страница 23: ...gh Drain 1 25 1 25 1 25 1 25 Extract 1 Coast 1 25 Rinse 2 S High 2 S High 2 S High 2 S High Drain 1 25 1 25 1 25 1 25 Extract 1 1 Coast 1 25 1 25 Bath 4 F C Low 4 F C Low 2 C High 4 F C Low Note A DIP switch setting allows configuring this operation for split fill Drain 1 25 1 25 1 25 1 25 Extract 6 2 5 7 7 Coast 1 25 1 25 1 25 1 25 Run Time 33 75 35 0 44 75 47 25 Key to Abbreviations D Usually de...

Страница 24: ...the on or off status of each switch 2 1 1 Is this switch position ON or OFF You can set any DIP switch position to on or off To turn a position off you must either press down on the side of the switch nearest the word OFF or slide the handle toward the position number To turn a position on you either press down on the side of the switch nearest the number or slide the white handle toward the word ...

Страница 25: ...ons 3 through 6 not used D Positions 7 and 8 Normal or diagnostic mode Figure 7 Typical DIP switch on 08BT168BT Graphic Legend A Position 1 Industry selection B Position 2 Formula set selection C Position 3 Cold final rinse D Positions 4 and 5 Hot water temperature E Position 6 Split bath temperature F Position 7 Run timer while heating G Position 8 Normal or diagnostic mode ...

Страница 26: ... sets switch position 7 off when preparing and testing the board before installation Set this switch position on before first commissioning the machine or before installing a replacement board The machine will not enter the diagnostics mode if this position is on 2 1 2 5 Position 8 Normal operation Switch position 8 determines whether the machine is configured for normal operation or for diagnosti...

Страница 27: ... uses formulas designed for the hospitality industry or formulas designed for healthcare facilities Set this position on to choose from the available hospitality formula sets Set this switch off to choose from the healthcare formula sets The available formulas in each set are listed in Section 1 5 Formulas in Milnor Washer extractors with E P OneTouch Controls 2 1 3 2 Position 2 Use Bed and Bath L...

Страница 28: ... Run bath timer while heating Switch position 7 determines whether the step timer runs or stops while the machine is heating to the desired bath temperature Set this switch position on to run the timer while heating This setting may increase productivity by allowing the machine to continue operation even though the desired bath temperature has not been achieved Set the switch off to stop the timer...

Страница 29: ...t of soiled goods that a washer extractor cylinder will accept depends on the following factors the internal volume of the cylinder the space into which the goods can be placed and the density weight and bulkiness of the specific goods For example many polyester cotton fabrics have relatively low weights for their bulk so one should rarely expect to be able to put in a published maximum capacity l...

Страница 30: ... beginning by pressing one of the the Formula Selection buttons with the door closed 3 2 1 3 Last Rinse Light This light comes on when the last bath step of any formula begins and remains on until the formula ends If the operator needs to add a chemical during the last bath such as softener he should add it as soon as this light comes on The Last Rinse light also alerts the operator that the machi...

Страница 31: ...ee Section ii Contacting Milnor 3 2 2 1 Formula Selection Buttons 3 2 2 1 1 Formula A button With the display kit attached and the machine in normal operation mode DIP switch position 8 is on this button stops the formula timer as long as it is held depressed The timer resumes running when the button is released Hold this button to simulate the timer stop feature Timer stop is used by some chemica...

Страница 32: ...ay of 75 seconds In testing mode the Terminate button provides input F to the microprocessor 3 2 2 3 Last Rinse Light During normal operation the Last Rinse light illuminates constantly from the beginning of the last bath step last rinse until the formula ends 75 seconds after the end of the final extract step In testing mode the Last Rinse light illuminates when output 8 is on 3 2 2 4 In Progress...

Страница 33: ...a Running light illuminates and the door locks immediately and the machine fills with water Once the door is locked the operator must end the formula early see Section 3 3 2 or wait for the formula to finish before opening the door 3 3 1 2 2 After Opening the Door during a Formula If you ended the previous formula early by opening the door you must press the Terminate button z before you can start...

Страница 34: ...ntrols are disabled for 75 seconds after the error occurs When this error occurs the microprocessor signals the error by flashing both the In Progress light and the Last Rinse light simultaneously Both lights flash on for two seconds then off for two seconds repeating for 10 minutes After 10 minutes both lights remain off Press the Terminate button z to recover from this error ensure that the door...

Страница 35: ...tal voltmeter if the schematic diagrams are available and you have a thorough understanding of how the machine normally operates The following rules will help you determine the current machine event The events in each formula are listed in Section 4 4 Event Timing for 08BT168BT Controller Boards Chart 1 Operating Sequence Part 1 Formula starts The selected formula starts immediately when the opera...

Страница 36: ...direction at wash speed for a duration of 20 seconds A5 Let basket coast dwell The controller commands the inverter to stop driving the basket The duration of this pause is 2 seconds A6 Rotate basket counter clockwise The controller commands the inverter to drive the basket in the counter clockwise direction at wash speed for a duration of 20 seconds A7 Is desired water level achieved NO Go to A3 ...

Страница 37: ...red to run or hold the step timer while the heating system is enabled before the desired temperature is first achieved A5 Enable step timer Chemical injections and subsequent actions are timed according to the step timer so these actions will not begin until the step timer starts A6 Wait 15 seconds A7 Enable chemical injection For each bath step in which chemicals are programmed the controller ena...

Страница 38: ...xt step is an extract Note 9 If the next step is a bath the controller allows the basket to coast for the last 15 seconds of the distribution time A7 Next step is a bath YES Go to Chart 2 NO Each step is either a bath step or an extract step A8 Accelerate basket to extract speed The controller commands the inverter to gradually accelerate the motor from distribution to extract speed A9 Extract spe...

Страница 39: ...to the large white Magnetek component motor inverter to your right 3 Connect the flat black connector on the display cable to MTA2 on the controller Use Figure 9 as a reference to properly orient the connector to the pins on the controller The four wires in the connector should be on the side nearest MTA3 and the two connector sockets without wires are nearest the long side of the board CAUTION 12...

Страница 40: ...wer to the machine you can select from five display modes without changing the DIP switch settings timer DIP switches inputs outputs and analog to digital channels The timer display shows certain general information about the current formula as explained in Section 4 2 2 2 1 The DIP switches display shows the on off status of each DIP switch position The inputs display Section 4 2 2 2 3 shows the ...

Страница 41: ...arts A6 View DIP switch display Press from the timer display to advance to the DIP switch display Details of the DIP switch display are described in Section 4 2 2 2 2 A7 View inputs Press when the DIP switch display is present and a formula is running to advance to the inputs display Details of the inputs display are described in Section 4 2 2 2 3 A8 View outputs Press when the inputs display is p...

Страница 42: ...Dx Level achieved and desired Low level is represented by 1 and high level is represented by 2 Achieved level is the number after A and desired level is the number after D For example A0 D2 indicates that level 2 is desired but the actual level is still below low level A2 D2 indicates that level 2 is desired and achieved T xxxx Timer status T Run indicates that the timer is running while T Stop in...

Страница 43: ...nctioning MTA3 5 Input is lost when door opens or inverter faults during a formula F Terminate button is depressed or door open desired MTA3 6 Testing terminates current formula G Low level achieved MTA3 7 H High level achieved or vibration safety switch closed MTA3 8 Water valves close or controller terminates extract step 4 2 2 2 4 Outputs Display From the inputs display press the Formula C butt...

Страница 44: ...nd 10 light illuminates when last bath step begins flashes to signal error j K9 Turn on In Progress light MTA7 pins 7 and 8 light is on throughout formula flashes to signal error k K10 In Progress Slave 08BT168AB or External Heat 08BT168BB MTA7 pins 3 and 4 actuates when optional external heat is desired l K11 Door Lock MTA7 pins 1 and 2 m K12 Flush chemical manifold MTA6 pins 9 and 10 n K13 Injec...

Страница 45: ...is raw counts value and converts it to a Celsius temperature degC 0027 The temperature shown here is derived from the displayed raw counts value This is the current temperature sensed by the temperature probe in Celsius degrees ADC1 0733 This display shows a value of 0733 for analog to digital channel 1 This channel is not used but is available for future applications mV 0435 This is the millivolt...

Страница 46: ... display press one time to view the on off status of each of the DIP switch positions Display or Action Explanation 87654321 The switch positions appear on the top line of the display A plus sign directly under a switch position indicates that the position is off while a minus sign indicates that the position is on 4 2 2 3 4 Viewing Inputs Two types of tests can be performed while observing the st...

Страница 47: ...tton is working and the processor is correctly interpreting the signal Door Closed and inverter functioning Input E This input is grounded when the processor sees the that door is securely closed and the inverter is functioning properly The machine will not run if this input is not grounded Terminate button Input F This input is grounded when the Terminate button z is pressed Low level achieved In...

Страница 48: ...d two types of results can be achieved from any output depending on how it is used in the machine Direct outputs These outputs such as the drain output relay K2 and the last rinse output relay K8 act as a switch in the circuit for the device to which they are assigned Output K2 is described above Output K8 closes when the last bath step of a formula begins providing power to the Last Rinse light o...

Страница 49: ...n the relay should be off dropping to 0 volts when the relay should be on Drain Closed Output 02 This output relay closes to energize the normally open drain valve causing it to close Test relay K02 by observing the drain valve under the machine or by checking for control voltage between fuse EF71B and pin 3 of MTA5 when the relay should be closed drain closed dropping to 0 volts when the relay sh...

Страница 50: ... to lock the door Flush Chemical Manifold Output 12 When this output is on control voltage flows between fuse EF71B and pin 1 of MTA7 This signal tells the chemical supply system that the chemical injection is complete and the machine desires to flush the chemical injection manifold Inject Detergent Output 13 When this output is on control voltage flows between fuse EF71B and pin 7 of MTA6 This si...

Страница 51: ...speed test and return to Output 00 Door unlock button If the command to accelerate to extract speed was entered the basket coasts for 75 seconds with all controls disabled when the speed test is terminated End of BICEPT02 BICEUF02 Published Book specs Dates 20060823 20060823 20060823 Lang ENG01 Applic CEP 4 3 Event Timing for 08BT168AT Controller Boards The following tables list the events in each...

Страница 52: ...89 20 Sour softener Cold water to low level 89 105 21 Drain 105 110 22 Extract 110 134 23 Coast 134 139 Table 14 Events for Hotel and Hospitality Set 1 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 24 Suds Hot water to low level 0 28 25 Drain 28 33 26 Bleach Hot water to low level 33 61 27 Drain 61 66 28 Rinse Hot water to high level 66 74 29 Drain 74 79 30 Extract 79 8...

Страница 53: ...se Split water to high level 113 121 51 Drain 121 126 52 Extract 126 130 53 Coast 130 135 54 Sour softener Cold water to low level 135 151 55 Drain 151 156 56 Extract 156 184 57 Coast 184 189 4 3 1 2 Formula Set 2 Table 16 Events for Hotel and Hospitality Set 2 Formula A Current Event Event Type Attributes Start Time QQQ End Time QQQ 58 Suds Hot water to low level 0 40 59 Drain 40 45 60 Rinse Hot ...

Страница 54: ...in 99 104 78 Sour softener Cold water to low level 104 120 79 Drain 120 125 80 Extract 125 135 81 Coast 135 140 Table 18 Events for Hotel and Hospitality Set 2 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 82 Suds and bleach Hot water to low level 0 80 83 Drain 80 85 84 Rinse Hot water to high level 85 93 85 Drain 93 98 86 Rinse Hot water to high level 98 106 87 Drain 1...

Страница 55: ...it water to high level 112 120 106 Drain 120 125 107 Extract 125 129 108 Coast 129 134 109 Rinse Split water to high level 134 142 110 Drain 142 147 111 Sour softener Cold water to low level 147 163 112 Drain 163 168 113 Extract 168 196 114 Coast 196 201 4 3 2 Healthcare Software 4 3 2 1 Formula Set 1 Table 20 Events for Healthcare Set 1 Formula A Current Event Event Type Attributes Start Time QQQ...

Страница 56: ...in 113 118 22 Sour softener Cold water to low level 118 134 23 Drain 134 139 24 Extract 139 163 25 Coast 163 168 Table 22 Events for Healthcare Set 1 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 26 Flush Split water to high level 0 8 27 Drain 8 13 28 Flush Split water to high level 13 21 29 Drain 21 26 30 Suds Hot water to low level 26 54 31 Carryover Hot water to high...

Страница 57: ...Split water to high level 122 130 56 Drain 130 135 57 Rinse Split water to high level 135 143 58 Drain 143 148 59 Sour softener Cold water to low level 148 164 60 Drain 164 169 61 Extract 169 197 62 Coast 197 202 4 3 2 2 Formula Set 2 Table 24 Events for Healthcare Set 2 Formula A Current Event Event Type Attributes Start Time QQQ End Time QQQ 63 Flush Split water to high level 0 8 64 Drain 8 13 6...

Страница 58: ...n 99 104 85 Sour softener Cold water to low level 104 120 86 Drain 120 125 87 Extract 125 135 88 Coast 135 140 Table 26 Events for Healthcare Set 2 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 89 Suds and bleach Hot water to low level 0 80 90 Drain 80 85 91 Rinse Hot water to high level 85 93 92 Drain 93 98 93 Rinse Hot water to high level 98 106 94 Drain 106 111 95 Ri...

Страница 59: ...xtract 156 184 120 Coast 184 189 End of BICEUF02 BICEUF03 Published Book specs Dates 20060823 20060823 20060823 Lang ENG01 Applic CEP 4 4 Event Timing for 08BT168BT Controller Boards The following tables list the events in each formula This information is especially useful when testing the machine with the display kit connected as explained in Section 4 1 Troubleshooting Errors 4 4 1 Hotel and Hos...

Страница 60: ...89 20 Sour softener Cold water to low level 89 105 21 Drain 105 110 22 Extract 110 134 23 Coast 134 139 Table 30 Events for Hotel and Hospitality Set 1 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 24 Suds Hot water to low level 0 28 25 Drain 28 33 26 Bleach Hot water to low level 33 61 27 Drain 61 66 28 Rinse Hot water to high level 66 74 29 Drain 74 79 30 Extract 79 8...

Страница 61: ...se Split water to high level 113 121 51 Drain 121 126 52 Extract 126 130 53 Coast 130 135 54 Sour softener Cold water to low level 135 151 55 Drain 151 156 56 Extract 156 184 57 Coast 184 189 4 4 1 2 Formula Set 2 Table 32 Events for Hotel and Hospitality Set 2 Formula A Current Event Event Type Attributes Start Time QQQ End Time QQQ 58 Suds Hot water to low level 0 40 59 Drain 40 45 60 Rinse Hot ...

Страница 62: ...in 99 104 78 Sour softener Cold water to low level 104 120 79 Drain 120 125 80 Extract 125 135 81 Coast 135 140 Table 34 Events for Hotel and Hospitality Set 2 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 82 Suds and bleach Hot water to low level 0 80 83 Drain 80 85 84 Rinse Hot water to high level 85 93 85 Drain 93 98 86 Rinse Hot water to high level 98 106 87 Drain 1...

Страница 63: ...o high level 112 120 106 Drain 120 125 107 Extract 125 129 108 Coast 129 134 109 Rinse Split water to high level 134 142 110 Drain 142 147 111 Sour softener Cold water to low level 147 163 112 Drain 163 168 113 Extract 168 196 114 Coast 196 201 4 4 2 Healthcare Software 4 4 2 1 Formula Set 1 Table 36 Events for Healthcare Set 1 Formula A Current Event Event Type Attributes Start Time QQQ End Time ...

Страница 64: ...3 118 137 Sour softener Cold water to low level 118 134 138 Drain 134 139 139 Extract 139 163 140 Coast 163 168 Table 38 Events for Healthcare Set 1 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 141 Flush Split water to high level 0 8 142 Drain 8 13 143 Flush Split water to high level 13 21 144 Drain 21 26 145 Suds Hot water to low level 26 54 146 Carryover Hot water to...

Страница 65: ...t water to high level 122 130 171 Drain 130 135 172 Rinse Split water to high level 135 143 173 Drain 143 148 174 Sour softener Cold water to low level 148 164 175 Drain 164 169 176 Extract 169 197 177 Coast 197 202 4 4 2 2 Formula Set 2 Table 40 Events for Healthcare Set 2 Formula A Current Event Event Type Attributes Start Time QQQ End Time QQQ 178 Flush Split water to high level 0 8 179 Drain 8...

Страница 66: ... 104 200 Sour softener Cold water to low level 104 120 201 Drain 120 125 202 Extract 125 135 203 Coast 135 140 Table 42 Events for Healthcare Set 2 Formula C Current Event Event Type Attributes Start Time QQQ End Time QQQ 204 Suds and bleach Hot water to low level 0 80 205 Drain 80 85 206 Rinse Hot water to high level 85 93 207 Drain 93 98 208 Rinse Hot water to high level 98 106 209 Drain 106 111...

Страница 67: ... 13 220 Suds Hot water to low level 13 53 221 Drain 53 58 222 Bleach Hot water to low level 58 86 223 Drain 86 91 224 Rinse Hot water to high level 91 99 225 Drain 99 104 226 Extract 104 108 227 Coast 108 113 228 Rinse Split water to high level 113 121 229 Drain 121 126 230 Extract 126 130 231 Coast 130 135 232 Sour softener Cold water to low level 135 151 233 Drain 151 156 234 Extract 156 184 235...