Pellerin Milnor Corporation
25
Figure 15.
Chemical
Injection Dialog Box
Add the chemical according to the chemical suppliers instruc-
tions, then touch
to cancel the operator signal and resume
the formula.
4.1.2
Error Intervention
BNCLJT06.C02 0000214536 E.3 C.3 C.4 9/11/20 11:26 AM Released
The operator signal sounds if an error occurs. See
for a list of possi-
ble error conditions. Contact a service technician or check the separate controller reference man-
ual if you cannot correct the error.
4.1.3
Formula Intervention
BNCLJO07.R01 0000195434 E.3 C.3 G.2 10/9/20 12:06 PM Released
Formula intervention allows you to manually alter a wash formula in production (while it runs).
You can adjust the:
•
step timer
•
water valves
•
drain and reuse valves
•
steam and cooldown controls
•
cylinder speed
•
bath temperature and level
The changes you make while in formula intervention mode do not alter the programming of the
formula (the step decisions). Formulas proceed normally in formula intervention mode aside from
the changes you make.
Chemical suppliers and service technicians can use formula intervention to test formulas and con-
firm proper operation of the machine components. For example, a service technician may want to
turn the steam valve on to confirm proper operation.
Operators might also use formula intervention if it is necessary to make a temporary, or one-time
change to a wash formula. For example, the operator may want to stop the timer to slowly add a
chemical through the soap chute.
Содержание MilTouch MWB26Z
Страница 2: ......