Pellerin Milnor Corporation
45
•
To remove the random values from these two decisions and make wash speeds 2 and 3 equiv-
alent to wash speeds 0 and 1, configure the alternate ON time for 20 seconds and the alternate
OFF time to 3 seconds.
Display or Action
Explanation
ALT. ON TIME ?
003
This value is the time in seconds the motor drives the basket when
wash speed 2 or 3 is selected. The range for this value is 003 sec-
onds to 255 seconds.
ALT. OFF TIME ?
003
This value is the time in seconds the motor is off between basket
reversals when wash speed 2 or 3 is selected. The range for this
value is 003 seconds to 255 seconds.
Fill Error Time:MM
Min=00, Max=15
0
0
This decision appears only on machine models with software
WUV7J1B/2300K and later.
If this value is set to
00
, the machine will wait 10 minutes for lev-
el to be achieved. If level is not achieved in 10 minutes, the opera-
tor signal sounds. The water valves remain open during the signal.
If this value is set within the valid range (
01
through
15
), then the
machine will wait the set time for level to be achieved. If level is
not achieved in the set time, the water valves close. The operator
must terminate the formula or reset the error timer. If the error
timer is reset, the machine will try again to fill.
2.3.5
Restoring the Standard Formulas
BNCJUP02.C01 0000191351 C.2 D.2 B.4 1/2/20 1:16 PM Released
Programming mode 3
allows the owner/operator with access to a programming key to perform
either of these two actions:
1.
Option 0
replaces all existing formulas with the factory default formulas for the selected in-
dustry configuration. This selection replaces formulas 1 through 10 with the standard industry
formulas and removes all data from formulas 11 through 30.
2.
Option 1
replaces only formulas 1 through 10 with the standard industry formulas. This
leaves any user-programmed data in formulas 11 through 30 intact.
CAUTION:
Avoid Data Loss —
Other than the two methods described above, it is not
possible to selectively delete field-modified or field-programmed formulas
with this programming mode. This mode erases all field-programmed for-
mulas 1 through 10 or 1 through 30 as specified. For selective deletions
and modifications, use
Program mode 1
(Add/Change Formula).
2.3.5.1
Chart 1: Restore Standard Formulas (Part A)
BNCJUP02.T01 0000191350 C.2 D.2 A.6 1/2/20 1:16 PM Released
1. Start
2. Restore standard formulas?
Содержание E-P Plus
Страница 2: ......