32
Pellerin Milnor Corporation
5
Early=Yes; After=No; Timer=Stops. Control starts steaming at
lowest safe level; steam is not allowed after temperature is first
achieved; timer stops while steaming up to temperature.
6
Early=Yes; After=Yes; Timer=Stops. Control starts steaming at
lowest safe level; if necessary, steam is allowed after temperature
is first achieved; timer stops while steaming up to temperature.
Table 5.
Summary of E-P Plus Steam Code Choices
Steam Code
Steaming can begin at
the earliest safe level
Steaming can occur
after temperature is
initially achieved
Step timer runs or stops
while steaming to the de-
sired temperature.
0
No steam allowed in this bath
1
No
Yes
Runs
2
No
No
Stops
3
No
Yes
Stops
4
Yes
Yes
Runs
5
Yes
No
Stops
6
Yes
Yes
Stops
2.3.3.6.6
Injecting Chemicals
BNCJUP03.C18 0000192002 C.2 D.2 C.3 1/2/20 1:16 PM Released
Display or Action
Explanation
03 TMMQFFFHC LS
C
WSS*
01
X
Chemicals can be added to any bath other than a cooldown bath.
A standard chemical injection can be prevented by commanding
C = 0 (no chemical in this bath) or by commanding SS = 00 (zero
seconds of chemical inject time). Up to five chemical injections
per bath step are allowed.
0
No chemical in this bath
2
Inject chemical number 2
5
Inject chemical number 5 (five is maximum number of chemicals)
03 TMMQFFFHC LSC
W
SS*
01
1
Select the option determining the point in the step at which this
chemical will be injected.
0
Inject chemical while filling. The chemical will be injected simul-
taneously with the opening of the water valves.
1
Inject chemical when level satisfied. The chemical injection be-
gins only after the commanded bath level has been achieved.
2
Inject chemical when level and temperature are satisfied. This op-
tion is only available if a steam code of 2, 3, 5, or 6 is used (
2.3.3.6.5: How to Select the Steam Code, page 31
) to achieve a
specified temperature with
Timer Stops
commanded (also de-
scribed in
2.3.3.6.5: How to Select the Steam Code, page 31
).
Содержание E-P Plus