Pellerin Milnor Corporation
143
Figure 65.
Vibration Switch
Legend
A...
Eccentric weight (adjusts up and down)
B...
Mounting bracket
C...
Actuating arm
D...
Microswitch (adjusts side to side)
For machines with rigid mounted shells, where the machine is bolted to a very substantial founda-
tion, very little machine movement will occur for a given degree of out-of-balance. Under such
conditions it may be better to adjust the switch to be very sensitive. With less substantial founda-
tions (e.g., ones where the sub-soil is mushy or springy or otherwise not as desirable), consider-
ably greater machine movement will occur for a given degree of out-of-balance, in which case a
less sensitive
vibration switch
setting may be indicated.