Installation—

30022H8J
Washer-Extractors

PELLERIN MILNOR CORPORATION

POST OFFICE BOX 400, KENNER, LOUISIANA 70063-0400, U.S.A.

Содержание 30022H8J

Страница 1: ...r ECN MAI30H7XAE 2003062N Publishing System TPAS Access date 2 3 2003 Document ECN s Latest Available Installation 30022H8J Washer Extractors PELLERIN MILNOR CORPORATION POST OFFICE BOX 400 KENNER LOUISIANA 70063 0400 U S A ...

Страница 2: ...ublishing system access date and whether the document ECN s are the latest available or exact References to Yellow Troubleshooting Pages This manual may contain references to yellow pages Although the pages containing troubleshooting procedures are no longer printed on yellow paper troubleshooting instructions if any will be contained in the easily located Troubleshooting chapter or section See th...

Страница 3: ...tors BIWUUI02 20001108 3 Avoiding Damage From Allied Remote Chemical Delivery Systems BIWUUI03 20030129 9 Section 1 Installation 10 Handling and Setting Procedures for 30022H7J and 30022H8J Washer Extractors MSIN0705AE 2000266V 14 Service Connections BIRQVI01 20020911 19 Section 2 Dimensional Drawings 21 Dimensional Drawing 30020H8J BD3022H8BE 2001506D ...

Страница 4: ......

Страница 5: ...trong and rigid enough and has not subsided to leave the floor slab suspended without support on grade installations can often be made directly to an existing floor slab if it has enough strength and rigidity to safely withstand our published forces without transmitting undue vibration If the subsoil has subsided or if the floor slab itself has insufficient strength and rigidity a deeper foundatio...

Страница 6: ...ating speeds of the machine s compared to the natural frequencies of the floor and or any other supporting structure s A qualified soil and or structural engineer must be engaged for this purpose Figure 1 How Rotating Forces Act on the Foundation Typical Machine Legend A Direction of force B Load C Rotation Frequency RPM 60 Figure 1 above is intended to depict both on grade and above grade install...

Страница 7: ... interfacing with allied chemical systems and information pertinent to chemical use in general are provided elsewhere in the product manuals see Note 1 Figure 1 Pumped Chemical Inlets on CBW Batch Washer Note 1 Misuse of laundering chemicals such as injecting excessive concentrations of chlorine bleach or permitting acid sours to react with hypo chlorite due to incorrect formulation can also be ha...

Страница 8: ... the machine particularly when it is idle can destroy machine components and textiles left in the machine Pellerin Milnor Corporation accepts absolutely no responsibility for damage to its equipment or to textiles therein from abnormal contact with chemicals Ensure that the chemical system prevents unintentional release of chemicals Inspect regularly for proper operation and evidence of damage 2 R...

Страница 9: ...iphon into the machine T Chemical tank 2 2 Ensure the Chemical Lines Cannot Dribble The pumped chemical system may provide a means of positively closing the chemical line at the pump location but not at the injection site Hence any concentrated chemical that remains in the injection line between the pump and the machine is free to flow into the machine Some examples of this are shown in Figure 3 ...

Страница 10: ...llowing are some of the possible methods the manufacturer or supplier may wish to use as appropriate 3 1 Siphoning Positively close the line If the pump does not provide positive closure when the system is off employ a shutoff valve in the line to serve this purpose 3 2 Siphoning Break the siphon Provide an air gap or vacuum breaker in the chemical delivery line This must be located above the full...

Страница 11: ...ystem is off T Chemical tank 4 Guarding Against Leaks All personnel who may work with the chemical system e g chemical system manufacturer chemical system supplier chemical supplier operator maintenance personnel should be vigilant in observing for leaks in the system When connecting or reconnecting chemical lines whether at installation after taking samples or when replacing components at a minim...

Страница 12: ......

Страница 13: ...Section 1 Installation ...

Страница 14: ... lifting is required 3 Use skids with the forklift Lift machine from front only If possible leave the machine on the shipping skids until it is about to be placed in its final position Once the skids are removed take care in placing forks under the machine Do not allow the forks to come in contact with valves piping motors etc located under the machine 4 Never push pull or exert pressure on any co...

Страница 15: ...ovided on the dimensional drawing see Table of Contents However never install anchor bolts firmly in the foundation using only the dimensional drawing or a template Approximate anchor bolt locations may be determined from a foundation template standard equipment on some machines optional on others Rec ommended anchor bolt installation see dimensional drawing calls for each anchor bolt to be set in...

Страница 16: ...r surface as specified in the dimensional drawing Add shims as necessary to level the machine from left to right and front to back Use a carpenter s level along the right and left side of the base to determine if the machine is level from front to back Place a level laterally across the base plates to deter mine if the machine is level from right to left Install anchor bolts taking care to align t...

Страница 17: ...when the fasteners are tightened Total area under each base plate must be completely filled with grout to a thickness of 3 4 19 Voids under base plates can magnify vibration causing unsatisfactory operation Use only industrial strength non shrinking grout If the grout after mixing is of proper consistency pack or trowel it by hand If the grout after mixing is too thin causing it to flow from under...

Страница 18: ...ction and may damage machine components 2 Throughly flush all water lines before making connections 3 When connecting water and steam inlets always install unions and shut off valves at the point of connection to permit removal of the machine components for servicing when necessary 20DC8 PRWX T 3P PVT 7PiPaSb Pumped chemical systems if not properly installed can cause corrosion damage See the refe...

Страница 19: ...th the motor fuses supplied with the machine depend on the machine voltage See the fuse and wire sizing information in the schematic manual and on the machine nameplate See dimensional drawings in this manual for electrical connection locations 1 Electrical connections must be made by a competent electrician 2 See fuse and wire sizing information in the schematic manual and on the machine nameplat...

Страница 20: ... of machine Figure 2 Line Voltage Switch Set for 240 Volt Operation AT eT BWX__X V ATbcaPX cb Remove all shipping restraints usually marked in red Restraints may be located behind access panels Restraints may include the vibration switch restraint Figure 3 Typical Vibration Switch showing restraint in place ...