Страница 1: ...XPS 10 F Series Transducer Technology based Customer driven April 1998 Instruction Manual PL 551 33455510 Rev 1 0 ...

Страница 2: ...ude ultrasonic and capacitance level measurement in line weighing of dry bulk solids and motion sensing Milltronics is established world wide through associate offices and representatives Our network is continually being refined to provide our customers with first rate sales information engineering assistance and after sales support For more details on our products and service please contact us an...

Страница 3: ...e in a line referred to as the axis of transmission Where power is reduced by half 3 dB a conical boundary defining the sound beam centered about the axis of transmission is established The diametric measurement of the cone in degrees defines the beam angle Impedance matching techniques are used to optimize the transfer of power from the transducer into air and vice versa The XPS F series transduc...

Страница 4: ...Kynar colour slate gray mounting 1 NPT conduit connection options factory flange to suit ANSI standard submergence shield where flooding can occur split flange for field mounting to suit ANSI standard cable 2 wire shielded twisted 0 5 mm2 20 AWG PVC jacket Supply Source transducer shall only be supplied by a Milltronics certified controller Weight kg lb 0 8 1 7 Separation 365 m 1200 ft from transd...

Страница 5: ...al flange refer to associated instructions standard optional split flange refer to associated instructions Hazardous seal supplied by others to suit hazardous area classificaton Model Dimension XPS 10 F A 86 mm 3 4 B 122 mm 4 8 C to suit ANSI standard D 128 mm 5 0 E 124 mm 4 9 F 152 mm 6 0 nominal PL 551 5 ...

Страница 6: ...lids applications a Milltronics Easy Aimer should be used to facilitate aiming of the transducer Do not overtighten mounting Hand tightening of the mounting hardware is sufficient Secure installation by connecting a safety chain from the transducer to a structural member Consider the optional temperature sensor when mounting the transducer MOUNTING SOLIDS APPLICATIONS Hazardous seal supplied by ot...

Страница 7: ... hazardous seal transducer safety chain flexible conduit steel channel hazardous seal safety chain submergence shield Flexible conduit mounted transducer should not be subjected to wind vibration or jarring Submersible transducer used in applications where flooding is possible PL 551 7 ...

Страница 8: ... flanged transducer bolt gasket nut hazardous seal Customer flanged standpipe If a metal flange must be welded to pipe refer to Liquid Applications Standpipes Flanged Flange gasket hazardous seal and hardware supplied by customer Refer to Liquid Applications Standpipes hazardous seal Blind Flange PL 551 8 ...

Страница 9: ...Wire Extension Coaxial Extension blk wht drain shield Milltronics transceiver typical blk drain shield wht extend cable using 18 AWG shielded twisted pair extend cable using RG 62 A U coax for optimum noise immunity junction box PL 551 9 ...

Страница 10: ...ocal governing regulations Do not route cable openly For optimum isolation against electrical noise run cable separately in a grounded metal conduit Seal all thread connections to prevent ingress of moisture Do not run cable near high voltage or current runs contactors and SCR control drives PL 551 10 ...

Страница 11: ...ance LIQUID APPLICATIONS STILLING WELL OCM blind flange air vent TS 3 transducer standpipe bracing standpipe inlet stilling well primary element stilling well inlet Refer to Liquid Applications Standpipes the use of a TS 3 temperature sensor provides better temperature tracking in applications where the temperature can change quickly PL 551 11 ...

Страница 12: ...ell to create an air pocket in front of the transducer face The associated transceiver interprets this as a flooding condition and reacts accordingly Refer to transceiver manual for programming requirements transducer submergence shield air pocket refer to associated instruction manual for assembly details on applicable models hazardous seal PL 551 12 ...

Страница 13: ...l in applications opening into a vessel or larger area Otherwise additional blanking will be required to compensate for the interference zone created by the opening flanged transducer vessel no additional blanking required no intersection vessel nipple welded into blind flange transducer sound beam intersects no vessel no additional blanking required near blanking extension of 150 mm 6 past end of...

Страница 14: ...issed improperly leveled transducer 4 When performing an empty or full calibration the tank must contain its normal vapour and be at its normal temperature 5 Hazardous seal supplied by others to suit hazardous area classification tank manufacturer s empty level discharge Empty level for alternate location Below this level echo would reflect away from the transducer may require target to obtain emp...

Страница 15: ...LIQUID APPLICATIONS WATER WASTEWATER DIFFERENTIAL LEVEL PUMP CONTROL SEWAGE LIFT PL 551 15 ...

Страница 16: ...nd aimed at discharge in order to read bin when empty 2 Avoid intersecting bin wall seams structural members and wall irregularities Otherwise 5 On dual discharge bins aim each transducer at the discharge point 4 On fluid like solids aim transducer perpendicular to material surface Easy Aimer bin wall seams filling profile emptying profile transducer minimal angle of repose discharge 1 2 3 4 5 PL ...

Страница 17: ...vers where available 3 Transducer should be aimed away from wall projections 4 Hazadous seal supplied by others to suit hazardous classifications DRYER WOOD CHIPS 1 Transducer should be mounted perpendicular to slope of wood chips 2 Hazadous seal supplied by others to suit hazardous classifications agitator infeed infeed drag conveyor typical low level typical high level PL 551 17 ...