Page 64
IQ Radar 160/160 Ex
PL-550
Troubleshooting
Symptom
Cause
Action
Reads correctly
but occasionally
reads high when
vessel is not full
•
detecting close range
echo
•
build up near top of tank
or nozzle
•
water or other high
ε
r
material in antenna
threads
•
wrong antenna choice
for application
•
stand pipe problem
•
increase blanking
•
increase confidence
threshold P804
•
rod extensions may be
required
•
See Application Example:
Still Pipe on page 50
•
material is within near
blanking zone
•
tank near empty and low
ε
r
material
•
multiple echoes
processed
•
decrease blanking P800
(min. 0.4 m)
•
raise IQ160/160 Ex
•
decrease range extension
•
install still pipe deflector
(contact Milltronics)
•
set P820 to ‘6’
•
Standpipe too narrow
for length
•
See Rod Extension
Requirements on page 23
Level reading
lower than
material level
•
Internal seam in
standpipe
•
Inspect and remove seam
Maintenance
The IQ Radar 160/160 Ex requires no maintenance or cleaning; however, a
program of periodic checks is advised.
Содержание IQ Radar 160
Страница 1: ...33455500 Rev 3 1 IQ RADAR 160 Instruction Manual PL 550 January 2001 Q RADAR I60 ...
Страница 10: ...Page 10 IQ Radar 160 160 Ex PL 550 Specifications ...
Страница 32: ...Page 32 IQ Radar 160 160 Ex PL 550 Installation ...
Страница 35: ...PL 550 IQ Radar 160 160 Ex Page 35 Start Up Display Aiming the Hand Programmer ...
Страница 40: ...Page 40 IQ Radar 160 160 Ex PL 550 Start Up ...
Страница 52: ...Page 52 IQ Radar 160 160 Ex PL 550 Operation ...
Страница 62: ...Page 62 IQ Radar 160 160 Ex PL 550 Parameter Descriptions ...
Страница 66: ...Page 66 IQ Radar 160 160 Ex PL 550 Appendix I ...
Страница 68: ...Page 68 IQ Radar 160 160 Ex PL 550 Appendix II ...
Страница 74: ...Page 74 IQ Radar 160 160 Ex PL 550 Appendix III ...
Страница 80: ...Page 80 IQ Radar 160 160 Ex PL 550 Index ...