EnviroRanger Installation Guide 

 PL-601 

In

s

ta

lla

tio

n

 

Installing Optional Cards in Rack or Panel Units 

 

wire the communications cable to the 

SmartLinx terminal block (65 – 73) 

mounting posts 

female connector

and 

(used to install an 
optional SmartLinx 
card) 

battery 

male connector 

(used to install 
expansion memory 
card) 

male connector 

(used to install 
optional I/O cards) 

Содержание EnviroRanger ERS500

Страница 1: ...33456010 Rev 1 3 ENVIRORANGER ERS 500 INSTALLATION GUIDE Instruction Manual PL 601 January 2001 ENVIRORANGER ERS 500...

Страница 2: ...n and in electronic version We encourage users to purchase authorized bound manuals or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc Siemens Millt...

Страница 3: ...Power Interruptions 10 Installation 11 Mounting Considerations 11 Mounting 13 Installing the Battery 18 Installing Optional Cards 19 Wiring 23 System Diagram 23 Terminal Board 24 Cables 25 Transducer...

Страница 4: ...Page 4 EnviroRanger Installation Guide PL 601...

Страница 5: ...emperature 20 to 50 C 5 to 122 F Relative humidity 80 for temperatures up to 50 C 122 F Installation category II Pollution degree 2 Environmental Wall Mount Location indoor outdoor Altitude 2000 m max...

Страница 6: ...ixed 0 17 per C deviation from programmed value Outputs Transducer drive 315 V peak Relays3 4 control 1 alarm relay all relays rated 4 A at 250 V ac non inductive Control Relays 4 form A NO relays num...

Страница 7: ...U 84HP 19 sub rack Panel mount suitable for DIN 43700 72 x 144 standard panel cut out on 110mm 4 33 centres Wall mount 224mm W x 285mm H x 102mm D 8 8 W x 11 2 H x 4 0 D Type 4X NEMA 4X IP 65 Polycarb...

Страница 8: ...Page 8 EnviroRanger Installation Guide PL 601 Specifications...

Страница 9: ...network The EnviroRanger is flexible It can take discrete input from pumps or other devices to modify its operation and ca n also time events to maximize efficiency or minimize cost The EnviroRanger...

Страница 10: ...500 Parameters The primary method of configuring the EnviroRanger is using Milltronics Dolphin Plus software and a serial connection to the device Configuring the EnviroRanger using the optional Hand...

Страница 11: ...ll be 250 V The non metallic enclosure does not provide grounding between conduit connections Use grounding type bushings and jumpers Mounting Considerations The ideal location to mount the EnviroRang...

Страница 12: ...nent communications connection to the EnviroRanger terminal board RS 485 Connections RS 485 ports are available on optional I O cards See Optional Card Wiring on page 29 for wiring of the RS 485 Hand...

Страница 13: ...erminal board screws are supplied by the customer Metallic racks must be grounded Rack Mount 1 Install rails at positions 5 and 15 as in diagram below Note Positions are in relation to left end of rac...

Страница 14: ...d 16 4 Slide the EnviroRanger into the rack and press fit it with the rail mounted terminal board 5 Tighten the four mounting screws on the faceplate 6 Wire the unit from the back according to the Rac...

Страница 15: ...erminal board from the unit 72mm 2 8 144mm 5 7 152mm 6 0 11mm 0 4 195mm 7 7 mounting bracket hand tighten 1 in lb torque max 104mm 4 1 terminal board extends beyond panel faceplate clamping screw term...

Страница 16: ...o the top and bottom bottom first 4 Tighten the mounting bracket clamping screw top bottom 5 Wire terminal board as per the Rack or Panel Mount wiring on page 24 mounting bracket hand tighten to 1 in...

Страница 17: ...long screwdriver If your cable is routed through a conduit 2 Unplug the display ribbon cable from the motherboard 3 Remove the four mounting screws holding the motherboard to the enclosure 4 Be carefu...

Страница 18: ...ry power a capacitor will power the RAM for about 10 minutes The flash memory is updated every hour Therefore up to an hour of data logging can be lost if all of the following conditions happen the ex...

Страница 19: ...ance the existing EnviroRanger Communications System Expansion Memory Card Used in conjunction with the EnviroRanger s Optional Data Logging Feature Analog Input Output cards mA Output Card This card...

Страница 20: ...ds in Rack or Panel Units wire the communications cable to the SmartLinx terminal block 65 73 mounting posts female connector and used to install an optional SmartLinx card battery male connector used...

Страница 21: ...stic shield 2 Pry the top and bottom mounting brackets away from the unit as shown below 3 Align the I O card with the 36 pin male connector and the four standoffs 4 Press fit the I O card until it sn...

Страница 22: ...O card with the 36 pin male connector and the four standoffs 2 Use the screws supplied with the card to attach it to the mounting posts 3 Wire the I O Card as shown in the Optional Card Wiring table o...

Страница 23: ...nductors on shielded cables should be kept as short as possible to reduce noise on the line caused by stray transmission and noise pickup System Diagram Milltronics transducer Milltronics TS 3 tempera...

Страница 24: ...ltaneously Rack or Panel Mount This diagram is found on the side shield of the EnviroRanger Wall Mount ac version dc version Route wires to these terminals up Route wires to these terminals down Recom...

Страница 25: ...ut Relay to be copper conductors per local requirements to meet 250V 5A contact rating Transducers Warning Hazardous voltage present on transducer terminals during operation Run the transducer cable i...

Страница 26: ...n state Relay 5 can be wired either normally open or normally closed and will fail in its unenergized state Relay ratings 4 Form A NO relays 1 4 1 Form C NO or NC relay 5 4 A at 250 V ac non inductive...

Страница 27: ...used ensure the transducer cable s are run in separate grounded metal conduits Otherwise synchronize the level monitors so that no unit can transmit while another is waiting for echo reception To sync...

Страница 28: ...d performance is verified Notes for AC Power connections The equipment must be protected by a 15 A fuse or circuit breaker in the building installation A circuit breaker or switch in the building inst...

Страница 29: ...9 108 56 IN 2 OUT 1 OUT 1 10 109 57 IN 2 OUT 1 OUT 1 11 110 58 IN 3 OUT 2 OUT 2 12 111 59 IN 3 OUT 2 OUT 2 SPARE 112 60 SHLD SHLD SHLD COM 13 16 113 61 IN 4 OUT 3 IN 2 13 114 62 IN 4 OUT 3 IN 2 14 11...

Страница 30: ...allation Guide PL 601 Wiring Input and Output Option Card Rack or Panel Mount 2 mA Inputs 2 mA Outputs Powered by other sources Wall mount Input or Output Option Cards Wall mount 4 mA Input 4 mA Outpu...

Страница 31: ...Page 31 Wiring Input and Output Option Card Wall mount 2 mA Inputs 2 mA Outputs Powered by other sources Discrete Input mA Input Output Option Card Wall mount Discrete Inputs Powered by other sources...

Страница 32: ...the EnviroRanger for communications allows it to be integrated into a full SCADA system an industrial LAN or directly connected to a computer that is running Dolphin Plus RS 232 Serial Connection Rac...

Страница 33: ...a dc current between 10 and 50 V as the signal triggered by an external device such as a pump float or other alarm These external devices are either self powered or passive The self powered device sup...

Страница 34: ...he EnviroRanger Use this model of wiring if your external device does not provide power to the discrete inputs DI 6 DI 5 DI 4 DI 3 DI 2 DI 1 DI 7 DI 8 DI 7 DI 8 DI common is wired to 24V input contact...

Страница 35: ...Wall Mount Discrete inputs have a positive and negative terminal common neg for discrete inputs 1 to 4 discrete input pos 1 discrete input pos 2 discrete input pos 3 discrete input pos 4 discrete inp...

Страница 36: ...EnviroRanger Use this model of wiring if your external device does not provide power to the discrete inputs DI 6 DI 5 DI 4 DI 1 DI 2 DI 3 DI 7 DI 8 DI 7 DI 8 DI common is wired to 24V input contacts f...

Страница 37: ...EnviroRanger Installation Guide Page 37 Wiring Discrete Input Option Card Wall mount Note If you are wiring the 8DI 2AI 2AO Optional Card see page 31 instead Powered by other sources Powered by the E...

Страница 38: ...d What applications the EnviroRanger is being used in For example in a wet well pumping accuracy is not important but repeatability is Battery Replacement The battery Rayovac BR2032 has a life expecta...

Страница 39: ...ng the battery 18 introduction 9 Laptop Access 11 level system synchronization 27 library manuals 9 mA Input 27 Rack or Panel Mount 27 Wall mount 27 maintenance 38 memory 6 mounting 13 panel mount 15...

Страница 40: ...ror 6 Temperature Sensor 26 Rack or Panel Mount 27 Wall mount 27 terminal board rack and panel wiring 24 wall mount wiring 24 Transducers 7 25 Rack or Panel Mount 25 Wall Mount 25 User Guide 9 wall mo...

Страница 41: ...7ml19981cb01...

Отзывы: