The XPL Plus can be used to monitor almost any process (within the temperature,
measurement range, and chemical immunity capabilities of the system) where a distance
measurement or determination of presence vs. lack of presence of an object is desired.
By thoroughly reviewing the PARAMETERS sections, you may identify some interesting
ways of using the XPL Plus to monitor specific processes.
e.g. 1 In a paper mill, one transducer may be used to monitor roll diameter, while another
monitors the presence of paper to the roll. The feed can be stopped based on the roll
diameter or a paper break. e.g. 2 For a truck loading station, one transducer can monitor
truck position while another monitors load height. The discharge can be stopped if
the truck is out of position or when it’s full, and the discharge chute can be
positioned a minimal distance from the load during filling to keep dust down.
Siemens Milltronics has many years experience applying ultrasonic level measurement
to a variety of processes in the mining, aggregate, lumber, grain, chemical, pulp and
paper, water, and waste water industries.
If you encounter a difficulty applying the XPL Plus to a process measurement
requirement, or successfully apply the XPL Plus to a "unique process" we may have never
considered, contact Siemens Milltronics or your local distributor.
BIC-II Support
As preset, the XPL Plus provides a digital output via the
Peripheral Communications
(20
mA bipolar serial current loop) terminals, capable of supporting the Siemens Milltronics
BIC-II.
The XPL Plus utilizes
simplex convention
communication protocol. Data messages are
continuously transmitted at regular intervals (no poll is required) at 4800 baud. All data is
transmitted in structured messages of ASCII characters consisting of eight data bits, no
parity, and one stop bit.
If Peripheral Communications (P740) is set for "formatted" messages, a comma is inserted
between each message field (except immediately preceding the "End of Message"
characters).
MT-00 Measurement Message
Start of Message
Point #
Status
A
Status
C
Percent
End of Message
Temperature
Status
B
Reading
Message Type
e.g.
Содержание airanger XPL plus
Страница 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Страница 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 113: ......