7ML19981AN02
AiRanger XPL Plus – INSTRUCTION MANUAL
Page 63
mm
mmm
Enhancement P
a
ra
met
e
rs
P802
SUBMERGENCE SHIELD ON TRANSDUCER
Use this feature (if desired) when the transducer connected is equipped with a
submergence shield.
When the transducer is submerged, the XPL Plus detects that the monitored
surface is within the Near Blanking (P800) distance, and immediately advances
to "zero" distance operating displays and outputs accordingly.
values: 0 = off (preset)
1 = submergence transducer
P803
SHOT / PULSE MODE
Use this feature to increase response independent from Measurement
Response (P003).
Select "short and long" to have short and long acoustic shots fired each time a
vessel is scanned. Select "short" to have only short shots fired if the Echo
Confidence (P805) produced by a short shot exceeds the short Confidence
Threshold (P804).
This value is automatically altered when Measurement Response (P003) is
altered. See
Technical Reference
Measurement Response.
values: 1 = short
2 = short and long
P804 CONFIDENCE
THRESHOLD
Use this feature when an incorrect material level is reported.
The short and long Confidence Thresholds are preset to 10 and 5 respectively. If
the Echo Confidence (P805) of a particular echo exceeds the Confidence
Threshold, that echo is considered for evaluation by Sonic Intelligence®.
values: x.y x = short (0 to 99), y = long (0 to 99)
Содержание airanger XPL plus
Страница 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Страница 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 113: ......