7ML19981AN02
AiRanger XPL Plus – INSTRUCTION MANUAL
Page 31
mm
mmm
Appl
icat
ion P
a
ra
met
e
rs
P070
FAILSAFE TIMER
Enter the time to elapse (in minutes), upon a difficulty, before failsafe operation
is activated.
In the RUN mode, when a difficulty first occurs, the Reading, Bar Graph, relay
status, and mA outputs are held at "last known" values and the Failsafe Timer is
activated.
When a valid measurement is made before the timer expires, the XPL Plus
advances to the "new" material level (if changed) as normal (per Measurement
Response, P003) and the timer resets.
If the timer expires (before a valid measurement is made), the XPL Plus
advances to the Failsafe Material Level (P071) as restricted by Failsafe Advance
(P072).
When a valid measurement is made after the timer expires, the XPL Plus
advances to the "new" material level (if changed), as restricted by Failsafe
Advance (P072) and the timer resets.
If the timer expires due to a measurement difficulty, "LOE" flashes in the Reading
display.
Technical difficulty messages flash in the Reading display before the timer
expires. The offending terminal connections are displayed in the Auxiliary
Reading display
DISPLAY
CAUSE
"LOE"
weak echo (see
Troubleshooting Guide
Measurement
Difficulties)
"Short" short
circuited
transducer cable, or defective transducer
"OPEn"
open circuited transducer cable, or Point Number is scanned but
a transducer is not connected, or defective transducer
"Error"
reversed Ultrasonic/Temperature transducer terminal
connections or wrong Transducer (P004) entered.
While a short duration Failsafe Timer value may be required
(when process control equipment is used) avoid entering
a value so short as to cause nuisance activation.
This feature is automatically altered when Measurement Response (P003) is
altered.
values:
0.000 to 9999
Содержание airanger XPL plus
Страница 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Страница 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 113: ......