Parameter Reset Features
On initial power up, all parameters are at "original" values. In many cases, when a
Parameter Value is altered, associated Parameter Values are automatically altered
accordingly. When a Parameter Number is accessed, if the preset Parameter Value
displayed is acceptable, no entry is required.
To return an operator adjusted Parameter Value to the preset value, with the appropriate
Point Number and Parameter Number displayed:
Press
To reset numerous parameters to preset values, refer to Master Reset (P999).
Perform a Master Reset (P999) if the XPL Plus was "bench tested" using arbitrary
Parameter Values before system installation, following an EPROM replacement, or
whenever complete reprogramming is required.
Special Parameters
Some Parameter Values are for display purposes only and cannot be operator altered.
These are referred to as view only parameters. In the parameters sections of this
instruction manual, view only parameters are identified by a "(V)" beside the Parameter
Number.
Some Parameter Values must be common for all Point Numbers. These are referred to as
global parameters. When a global parameter is accessed, the Point Number display
automatically switches to Point Number 00, and returns to the Point Number previously
selected when a non-global parameter is accessed. In the parameters sections of this
manual, global parameters are identified by a "(G)" beside the Parameter Number.
Programming Security
All operator programming is retained in non-volatile memory, immune to power
interruptions. When programming is complete, the programmer may be removed and
locked away to prevent inadvertent programming alteration. The Lock (P000) parameter
may also be used.
Security Parameter
This parameter cannot be reset by pressing
P000 (G) LOCK
Use this feature (if desired) to secure all programming from inadvertent
alteration.
Direct access (cannot be scroll accessed) this parameter after all program-
ming is complete and enter any value (other than 1954) to activate the pro-
gramming Lock.
When Lock is activated, the XPL Plus may be switched from the RUN mode
to PROGRAM mode and the value of any parameter may be viewed but not
altered. To unLock, direct access this parameter and enter the value "1954".
values:
1954 = off (Parameter Value alteration permitted)
other = activated (programming secured)
Содержание airanger XPL plus
Страница 1: ...Instruction Manual March 2005 XPL PLUS airanger ...
Страница 10: ...Page 6 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 26: ...Page 22 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 82: ...Page 78 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 106: ...Page 102 AiRanger XPL Plus INSTRUCTION MANUAL 7ML19981AN02 ...
Страница 113: ......