OM-262379 Page 18
5-9.
Meter Board (PC20) DIP Switch Settings
265 368-B
DIP switch is
located behind
front panel as
shown.
1
2
3
4
5
1
2
3
4
5
Factory Default DIP Switch Settings To
Display Wire Speed As Inches Per Minute
Factory Default DIP Switch Settings To
Display Wire Speed As Meters Per Minute
Indicates switch does
not affect this function
Display Hold On
Displays will hold their last value for five seconds
after the trigger is released. After the hold times
out, the Voltmeter will show open circuit voltage or
weld voltage polarity. If the Wire Speed / Amper-
age Meter is set to display Amps, the amperage
value will hold, after the hold times out, preset Wire
Speed will be displayed.
Display Hold Off
Displays will not hold values. Immediately, when
the trigger is released, the Voltmeter will show
open circuit voltage or weld voltage polarity. The
Wire Speed / Amperage Meter will display preset
Wire Speed when the trigger is released.
Do Not Display Amperage
Wire Speed / Amperage Meter will display only
Wire Speed.
Display Amperage
Wire Speed / Amperage Meter will display Amps
while welding and Wire Speed while not welding.
If the hold function is enabled, Amps will be dis-
played during hold also.
Wire Speed − Inches per Minute
Displays Wire Speed in Inches per Minute.
Wire Speed − Meters per Minute
Displays Wire Speed in Meters per Minute.
Information Off
Information is not displayed.
Information On
With switch in ON position, at feeder power up,
feeder will display various sets of information.
Each set of information will be displayed for three
seconds.
Meter Board (PC20) Software Part Number
Top display will show the first three digits, bottom
display will show last three digits of the Meter
board (PC20) software revision level.
Motor Control Board (PC1) Software Part
Number
Top display will show the first three digits, bottom
display will show last three digits, of the Motor
Control Board (PC1) software revision level.
Accumulated Weld Time
This is the time the feeder has actually been used
for welding. This information will be displayed in
two halves. First being years and days, second in
hours and minutes. Top display will show years/
hours, bottom display will show days/minutes.
Weld Voltage Polarity
When the Voltmeter would normally display open
circuit voltage, the Voltmeter will display:
“EP” when connected as electrode positive. While
welding, and in Display Hold On mode, the Volt-
meter will display Weld Voltage.
“En.” when connected as electrode negative.
While welding, and in Display Hold On mode, the
Voltmeter will display Weld Voltage and the last
decimal point will remain lit. If Weld Voltage is
“23.4” the Voltmeter will display “23.4.”.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
Shows switch in ON/DOWN (closed) position
Shows switch in OFF/UP (open) position
Indicates switch does not affect this function
Meter Board (PC20) DIP Switch Settings
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5