background image

OM-220979 Page 4

1-4. California Proposition 65 Warnings

Welding or cutting equipment produces fumes or gases

which contain chemicals known to the State of California to

cause birth defects and, in some cases, cancer. (California

Health & Safety Code Section 25249.5 et seq.)

This product contains chemicals, including lead, known to

the state of California to cause cancer, birth defects, or other

reproductive harm. 

Wash hands after use.

1-5. Principal Safety Standards

Safety in Welding, Cutting, and Allied Processes,

 ANSI Standard Z49.1,

is available as a free download from the American Welding Society at

http://www.aws.org or purchased from Global Engineering Documents

(phone: 1-877-413-5184, website: www.global.ihs.com).

Safe Practices for the Preparation of Containers and Piping for Welding

and Cutting,

 American Welding Society Standard AWS F4.1, from Glob-

al Engineering Documents (phone: 1-877-413-5184, website:

www.global.ihs.com).

Safe Practices for Welding and Cutting Containers that have Held Com-

bustibles,

 American Welding Society Standard AWS A6.0, from Global

Engineering Documents (phone: 1-877-413-5184,

website: www.global.ihs.com).

National Electrical Code,

 NFPA Standard 70, from National Fire Protec-

tion Association, Quincy, MA 02269 (phone: 1-800-344-3555, website:

www.nfpa.org and www. sparky.org).

Safe Handling of Compressed Gases in Cylinders,

 CGA Pamphlet P-1,

from Compressed Gas Association, 14501 George Carter Way, Suite

103, Chantilly, VA 20151 (phone: 703-788-2700, website:www.cga-

net.com).

Safety in Welding, Cutting, and Allied Processes,

 CSA Standard

W117.2, from Canadian Standards Association, Standards Sales, 5060

Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5NS

(phone: 800-463-6727, website: www.csagroup.org).

Safe Practice For Occupational And Educational Eye And Face Protec-

tion,

 ANSI Standard Z87.1, from American National Standards Institute,

25 West 43rd Street, New York, NY 10036 (phone: 212-642-4900, web-

site: www.ansi.org).

Standard for Fire Prevention During Welding, Cutting, and Other Hot

Work,

 NFPA Standard 51B, from National Fire Protection Association,

Quincy, MA 02269 (phone: 1-800-344-3555, website: www.nfpa.org).
OSHA, Occupational Safety and Health Standards for General Indus-

try, Title 29, Code of Federal Regulations (CFR), Part 1910, Subpart Q,

and Part 1926, Subpart J, from U.S. Government Printing Office, Super-

intendent of Documents, P.O. Box 371954, Pittsburgh, PA 15250-7954

(phone: 1-866-512-1800) (there are 10 OSHA Regional Offices—

phone for Region 5, Chicago, is 312-353-2220, website:

www.osha.gov).

Applications Manual for the Revised NIOSH Lifting Equation

, The Na-

tional Institute for Occupational Safety and Health (NIOSH), 1600

Clifton Rd, Atlanta, GA 30329-4027 (phone: 1-800-232-4636, website:

www.cdc.gov/NIOSH).

1-6. EMF Information

Electric current flowing through any conductor causes localized electric

and magnetic fields (EMF). The current from arc welding (and allied pro-

cesses including spot welding, gouging, plasma arc cutting, and

induction heating operations) creates an EMF field around the welding

circuit.  EMF fields can interfere with some medical implants, e.g. pace-

makers. Protective measures for persons wearing medical implants

have to be taken. For example, restrict access for passers

by or con-

duct individual risk assessment for welders. All welders should use the

following procedures in order to minimize exposure to EMF fields from

the welding circuit:

1. Keep cables close together by twisting or taping them, or using a

cable cover.

2. Do not place your body between welding cables. Arrange cables

to one side and away from the operator.

3. Do not coil or drape cables around your body.

4. Keep head and trunk as far away from the equipment in the

welding circuit as possible.

5. Connect work clamp to workpiece as close to the weld as

possible.

6. Do not work next to, sit or lean on the welding power source.

7. Do not weld whilst carrying the welding power source or wire

feeder.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the

device manufacturer before performing or going near arc welding,  spot

welding, gouging, plasma arc cutting, or induction heating operations.

If cleared by your doctor, then following the above procedures is recom-

mended.

Содержание ROI BOX CE

Страница 1: ...ROI Remote Operator Interface CE Processes Description MIG GMAW Welding Wire Feeder OM 220979S 2016 02 File Advanced Manufacturing Systems Visit our website at www MillerWelds com ams...

Страница 2: ...ntinue the tradition They re just as committed to providing equipment and service that meets the high standards of quality and value established in 1929 This Owner s Manual is designed to help you get...

Страница 3: ...Label Location 12 4 2 Unit Specifications 12 4 3 Environmental Specifications 12 SECTION 5 INSTALLATION 13 5 1 Mounting Plate Hole Layout 13 5 2 Installing Insulator Kit 13 5 3 Remote Operator Interf...

Страница 4: ...I BOX CE 195383 Council Directives 2014 35 EU Low Voltage 2014 30 EU Electromagnetic Compatibility 2011 65 EU Restriction of the use of certain hazardous substances in electrical and electronic equipm...

Страница 5: ...neeling or lying or when there is a high risk of unavoid able or accidental contact with the workpiece or ground For these conditions use the following equipment in order presented 1 a semiautomaticDC...

Страница 6: ...ared according to AWS F4 1 and AWS A6 0 see Safety Standards D Do not weld where the atmosphere can contain flammable dust gas or liquid vapors such as gasoline D Connect work cable to the work as clo...

Страница 7: ...S can injure D Keep away from moving parts such as fans D Keep all doors panels covers and guards closed and securely in place D Have only qualified persons remove doors panels covers or guards for ma...

Страница 8: ...PA Standard 51B from National Fire Protection Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org OSHA Occupational Safety and Health Standards for General Indus try Title 29 Code of...

Страница 9: ...s dans un environnement humideou si l on porte des v tements mouill s sur des structures m talliquestelles que sols grilles ou chafaudages en position coinc e comme assise genoux ou couch e ou s il y...

Страница 10: ...br lures Le contact accidentel de l lectrode avec des objets m talliques peut provoquer des tincelles une explosion un sur chauffement ou un incendie Avant de commencer le soudage v rifier et s assur...

Страница 11: ...areil D Tenir l quipement c bles et cordons distance des v hicules mobiles lors de toute op ration en hauteur D Suivre les consignes du Manuel des applications pour l quation de levage NIOSH r vis e P...

Страница 12: ...ational Electrical Code NFPA Standard 70 from National Fire Protec tion Association Quincy MA 02269 phone 1 800 344 3555 website www nfpa org and www sparky org Safe Handling of Compressed Gases in Cy...

Страница 13: ...tion Safe37 2012 05 Wear dry insulating gloves Do not touch electrode with bare hand Do not wear wet or damaged gloves Safe2 2012 05 Protect yourself from electric shock by insulating yourself from wo...

Страница 14: ...welding voltage during operation keep hands and metal objects away Safe33 2012 05 Wear hat and safety glasses Use ear protection and button shirt collar Use welding helmet with correct shade of filte...

Страница 15: ...urge By Gas Fast Constant Current Circuit Breaker Constant Voltage Slow Trigger Hold Off Trigger Hold On I2 Rated Welding Current Increase Read Instructions U1 Primary Voltage U2 Conventional Load Vol...

Страница 16: ...d by the general public as the EMF limits for the general public might be exceeded during welding This equipment is built in accordance with EN 60974 1 and is intended to be used only in an occupation...

Страница 17: ...er 1 ROI Control 2 Insulator Plate 3 Mounting Plate 4 1 4 20x3 4 in Screw 4 5 Nylon Shoulder Washer 4 6 3 8 in Flat Washer 4 Place insulator plate between ROI base and metal mounting surface Place nyl...

Страница 18: ...ace 2 Swingarc Swivel Assembly 3 Boom 4 AA40G Wire Drive Assembly 5 Trigger Cable 1 2 3 4 5 5 803 698 E 5 4 Connection Diagram 1 Welding Power Source 2 Wire Feeder 3 Gas Cylinder 4 Gas Hose 5 Network...

Страница 19: ...ceptacle Information 9 Pin Pin Information A B I C H D G E F A Capacitor C1 to ground B Shield C Volt sense D Can low E Can high F 24 volts DC common G 24 volts DC H Motor voltage 40 volts DC common I...

Страница 20: ...play 2 1 Power Source Upper Display Lower Display Axcess Axcs 300 450 675 10 44 Voltage Range Net Wait DTEC OFF Process Setup Adjust Feeder Setup V t A 219 711 A 5 9 Dual Schedule Switch Option 1 Main...

Страница 21: ...ing of voltage arc adjust wire feed rate and time value for arc ends DS Dual Schedule Dual Schedule allows selecting a pair of programs that can be used together Feeder Set Up Allow selection of Seque...

Страница 22: ...le actual voltage while welding and 3 seconds hold value at end of weld Wire Type Selection of wire type by alloys and classification WFS Term used to represent wire feed speed In MIG mode wire feed s...

Страница 23: ...OM 220979 Page 19 6 3 Front Panel Sections See Section 6 5 See Section 6 6 See Section 6 9 See Section 6 8 See Section 6 7 See Section 6 4 Process Setup Adjust Feeder Setup V t A...

Страница 24: ...The display will show actual voltage for approximately 3 seconds after welding stops before returning to preset value 2 Upper Display Push Button Press the button to illuminate the LED and allow chan...

Страница 25: ...unction and can be adjusted using the Adjust knob 6 Lower Display Push Button 7 Lower Display Push Button LED Pressing the button illuminates the LED and selects either WFS or Arc Ctl value for changi...

Страница 26: ...s will exit the Sequence menu and return the system to standby mode 4 Trigger Control LED Press the Feeder Set Up button twice and the Trigger Control LED will illuminate and the upper display will sh...

Страница 27: ...n pressing the Process Set Up push button a sixth time will show PROG in the upper display and LOAD in the lower display The new program would be loaded for that particular program in slot 1 thru 8 If...

Страница 28: ...s and then ramps up to 700 ipm until trig ger is released or 30 seconds elapses If the gun trigger is still activated after 30 seconds the jog operation is terminated to prevent complete unspooling of...

Страница 29: ...Steel 90 Argon 10 CO2 Program 5 MIG 045 Mild Steel 75 Argon 25 CO2 Program 6 Accu pulse 045 Mild Steel 90 Argon 10 CO2 Program 7 Pulse 052 Mild Steel 90 Argon 10 CO2 Program 8 MIG 052 Mild Steel 75 Ar...

Страница 30: ...time is set to zero in any timed sequence the sequence is skipped Maximum IPM may actually be lower depending on the process and wire type selection Trigger Pressed Trigger Released Start Time Preflow...

Страница 31: ...tenance Disconnect power before maintaining Maintain more often during severe conditions n Check Z Change Clean l Replace To be done by Factory Authorized Service Agent Reference Every 3 Months l Unre...

Страница 32: ...R MOTR Section 8 2 F Arc Start Error ERR STRT Section 8 2 G No Tach Error ERR TACH Section 8 2 H Thermal Over Temperature ERR TEMP Section 8 2 I Unknown Error ERR UNKN Section 8 2 J Motor Communicatio...

Страница 33: ...software C No Coolant Flow Error ERR COOL Indicates no coolant flow in water flow switch option The error may be reset by reestablishing coolant flow to the gun and then pressing the Jog Purge button...

Страница 34: ...r Up Cnt that generated by the boost section of the inverter control board When either of these signals is active RC6 12 is pulled low this is the not ready line out of the inverter control board Shut...

Страница 35: ...chassis lifting eye bolts or weld secondary common Measure impedance between chassis and both weld secondary commons Measure the impedance across motor isolation barrier on motor housing All measureme...

Страница 36: ...lem is no longer an issue S A shorted output diode will cause an over current error and no weld output will be available N Release Trigger Error REL TRIG Indicates a timed weld has expired but the tri...

Страница 37: ...is message appears when RMD and Accuspeed demos are completed Pressing the Jog Purge button will change the screen to CYCL PWR on the display Turn unit power off and back on again RMD and Accuspeed sh...

Страница 38: ...OM 220979 Page 34 SECTION 9 ELECTRICAL DIAGRAM Figure 9 1 Circuit Diagram...

Страница 39: ...OM 220979 Page 35 214 842 F...

Страница 40: ...feeder 1 2 233582 PANEL pc card switch overlay 1 3 212808 BAFFLE pc mounting 1 4 097132 STAND OFF SUPPORT pc card 6 5 PC6 239601 WIRE FEED MODULE 1 6 098691 STAND OFF no 6 32 x 500 lg 250 hex stl m f...

Страница 41: ...SKTS service kit 1 PLG4 136810 HOUSING PLUG SKTS service kit 1 PLG81 115092 HOUSING PLUG SKTS service kit 1 PLG10 130203 HOUSING PLUG SKTS service kit 1 PLG50 136810 HOUSING PLUG SKTS service kit 1 PL...

Страница 42: ...Notes...

Страница 43: ...ns and Subarc SAW Torches Remote Controls and RFCS RJ45 Replacement Parts No labor Roughneck Guns Spoolmate Spoolguns Miller s True Blue Limited Warranty shall not apply to 1 Consumable components suc...

Страница 44: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Отзывы: