OM-225 216 Page 9
SECTION 3
−
DEFINITIONS
3-1. Symbols And Definitions
A
Amperes
Increase
Power Light
Low Air Pressure
Light
Loose Shield Cup
Light
Temperature Light
On
Off
SECTION 4
−
INSTALLATION
4-1. Specifications
Amperes Input
at Rated
Output
Plasma
Rated
Cutting
Input
Voltage
Rated Output
Output,
60 Hz,
Single-Phase
KVA/KW
Plasma Gas
Plasma
Gas Flow/
Pressure
Cutting
Capacity
at 10 IPM
Max
OCV
120 Volts
±
10%
(20 A)
27 A At 91 Volts DC
At 20% Duty Cycle
28.8 max;
0.30*
3.4 KVA
3.2 KW
4 5 CFM
120 Volts
±
10%
(15 A)
20 A At 88 Volts DC
At 35% Duty Cycle
20.6 max;
0.30*
2.5 KVA
2.3 KW
Air Or Nitrogen
Only At 90
−
110 PSI
(621
−
758 kPa)
4.5 CFM
(129 L/min)
At 60 PSI
(414 kPa)
3/8 in
(10 mm)
400 Volts
DC
240 Volts
±
10%
(27 A)
27 A At 91 Volts DC
At 35% Duty Cycle
13.9 max;
0.13*
3.3 KVA
3.0 KW
(414 kPa)
*While idling
4-2. Specifications For Torch
Air-cooled torch for plasma arc cutting (PAC)
35% duty cycle
Safety interlock devices shut down power source
Safety trigger guard
Cutting capacity: see Section 4-1
Содержание ICE-27T
Страница 4: ......
Страница 29: ...OM 225 216 Page 25 Notes...
Страница 30: ...OM 225 216 Page 26 SECTION 7 ELECTRICAL DIAGRAM Figure 7 1 Circuit Diagram...
Страница 31: ...OM 225 216 Page 27 224 682 B...