5-10. Selecting Cable Sizes*
!
Turn off power before connecting to weld output terminals.
!
Do not use worn, damaged, undersized, or repaired cables.
NOTICE
−
The Total Cable Length in Weld Circuit (see table below) is the combined length of both weld cables. For example, if the power source
is 100 ft (30 m) from the workpiece, the total cable length in the weld circuit is 200 ft (2 cables x 100 ft). Use the 200 ft (60 m) column to determine
cable size.
NOTICE
−
The Smart Feeder draws less than 200 amps from the power source. Use the weld cable sizes listed in the table below. The work
cable from the Smart Feeder should be as short as possible to ensure the best possible Pulsed-MIG and RMD performance.
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
Not Exceeding***
100 ft (30 m) or Less
150 ft
(45 m)
200 ft
(60 m)
250 ft
(70 m)
300 ft
(90 m)
350 ft
(105 m)
400 ft
(120 m)
Welding
Amperes
10
−
60%
Duty
Cycle
AWG (mm
2
)
60
−
100%
Duty Cycle
AWG (mm
2
)
10
−
100% Duty Cycle
AWG (mm
2
)
200
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
2/0 (70)
3/0 (95)
3/0 (95)
*
This chart is a general guideline and may not suit all applications. If cable overheats, use next size larger cable.
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
( ) = mm
2
for metric use
***For distances longer than those shown in this guide, call a factory applications rep. at 920-735-4505 (Miller) or 1-800-332-3281 (Hobart).
Ref. S-0007-L 2015
−
02
Notes
Содержание FieldPro Smart Feeder CE
Страница 4: ......
Страница 39: ...OM 264234 Page 33 Notes...
Страница 40: ...OM 264234 Page 34 SECTION 8 ELECTRICAL DIAGRAM Figure 8 1 Circuit Diagram For Wire Feeder...
Страница 41: ...OM 264234 Page 35 257 205 E...
Страница 52: ...Notes...
Страница 53: ...Notes...
Страница 54: ...Notes...