OM-2240 Page 20
4-10. Stick Connections
803 429-a
Y
Turn off power before mak-
ing connections.
1
Electrode Weld Output
Terminal
Connect electrode holder to weld
output terminal labeled Electrode.
2
Work Weld Output Terminal
Connect work lead to weld output
terminal labeled Work.
3
Remote 14 Receptacle
If desired, connect remote control
to Remote 14 receptacle (see Sec-
tion 4-7).
1
2
3
4-11. Electrical Service Guide
Actual input voltage should not fall below 103 volts AC or rise above 506 volts AC.
If actual input voltage is outside this range, unit may not operate according to
specifications.
NOTE
Single-Phase,
100% Duty
Cycle
Single-Phase,
60% Duty
Cycle
Three-Phase, 60% Duty
Cycle
Input Voltage
115
230
230
400
460
Input Amperes At Rated Output
28
20
12.3
7.6
6.0
Max Recommended Standard Fuse Rating In Amperes
1
Normal Operating
2
35
30
20
10
10
Min Input Conductor Size In AWG/Kcmil
10
12
14
14
14
Max Recommended Input Conductor Length
In Feet (Meters)
57 (17)
79 (24)
102
(31)
308
(94)
407
(124)
Min Grounding Conductor Size In AWG/Kcmil
10
12
14
14
14
Reference: 1999 National Electrical Code (NEC)
1 Choose a circuit breaker with time-current curves comparable to a time delay fuse. Time delay fuses are UL class RK5.
2 “Normal Operating” (general purpose - no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and
above).
Y
Failure to follow these fuse and circuit breaker recommendations could create an electrical shock or fire hazard.