OM-266621 Page 51
12-3. Grounding When Supplying Building Systems
ST-800 576-B
1
Equipment Grounding
Terminal
2
Grounding Cable
Use #8 AWG or larger insulated
copper wire.
3
Ground Device
Use ground device as stated in
electrical codes.
!
Ground generator to system
earth ground if supplying
power to a premises (home,
shop, farm) wiring system.
!
Also see AWS Safety &
Health Fact Sheet No. 29,
Grounding of Portable And
Vehicle Mounted Welding
Generators.
GND/PE
1
2
2
3
12-4. How Much Power Does Equipment Require?
S-0623
1
Resistive Load
A light bulb is a resistive load and
requires a constant amount of power.
2
Non-Resistive Load
Equipment with a motor is a non-re-
sistive load and requires
approximately six times more power
while starting the motor than when
running (see Section 12-8).
3
Rating Data
Rating shows volts and amperes, or
watts required to run equipment.
Amperes x Volts = Watts
Example 1:
If a drill uses 4.5 am-
peres at 115 volts, calculate its
running power requirement in watts.
4.5 A x 115 V = 520 W
The load applied by the drill is 520
watts.
Example 2:
If three 200 watt flood
lamps are used with the drill from Ex-
ample 1, add the individual loads to
calculate total load.
(3 x 200W) + 520 W = 1120 W
The total load applied by the three
flood lamps and drill is 1120 watts.
VOLTS 115
4.5
50/60
AMPS
Hz
1
2
3
3
Содержание Big Blue 450 Duo CST
Страница 18: ...OM 266621 Page 14...
Страница 34: ...Complete Parts List is available at www MillerWelds com OM 266621 Page 30 6 4 Fuel Hour Gauge Descriptions...
Страница 50: ...OM 266621 Page 46 SECTION 10 ELECTRICAL DIAGRAMS Figure 9 1 Circuit Diagram For Welding Generator...
Страница 51: ...OM 266621 Page 47 247 963 D...
Страница 61: ...Notes...
Страница 62: ...Notes...