General
OM-244 814 Page 49
SECTION 10
−
OPERATION
10-1. Operational Terms
The following is a list of terms and their definitions as they apply to this interface unit:
General Terms:
Arc Adjust
Term used to represent arc length adjustments in pulse programs. Increasing Arc Adjust increases
the actual arc length. Likewise, decreasing arc adjust shortens arc length. Arc Adjust is replaced by
volts in MIG programs.
AccuCurve
CV Pulse process using a pulse waveform with modified curves at particular locations within the
waveform. Has a distinguished change in arc characteristics. Front panel display is ACCU
−
CURV.
Accu-pulse
Pulse process utilizing constant current ramps with constant voltage control of peaks and
backgrounds. Adaptive response is controlled by peak, background, and minimum current levels.
Benefits are shorter arc lengths, better puddle control, more tolerant of tip-to-work variation, less
audible noise, no arc wandering, allows weld to fill in at toes increasing travel speed and deposition,
and more tolerant to poor fit up and gaps.
Adjust
Control knob used to change or set parameters and functions.
Amps
Indicates average amperage while welding and 3 seconds hold value at end of weld.
Arc Control
Allows setting of inductance and slope in MIG mode. In pulse and Accu-pulse mode, this adjustment
changes the arc characteristics by adjusting the preprogrammed factory pulse data.
Arc Length
Distance from end of wire electrode to weld pool.
Auto Thread
Method of jogging wire without holding jog or trigger switch. By rocking the switch from purge to jog
within 0.5 seconds will automatically feed wire for a factory default setting of 192 in (4877 mm) of wire
before stopping. Default setting is 192 at a feed rate of 700 ipm (these values can be changed using
the HTML pages). Pressing jog, purge, or trigger switch will terminate the auto-threading feature.
Carbon Arc Cutting/Gouging
A cutting process by which metals are melted by the heat of an arc using a carbon electrode. Molten
metal is forced away from the cut by compressed air.
Crater
Allows setting of voltage/arc adjust, wire feed rate, and time value for arc ends.
DS (Dual Schedule)
Dual Schedule allows selecting a program within a pair of programs by means of a dual schedule
switch.
Feeder Set Up
Allow selection of Sequence and trigger functions.
Gas Type
Selection of shielding gas being used in application.
IGNR (Ignore)
Allows the use of a dual schedule switch between ignore welds and count welds when using Insight
Centerpoint.
Inductance
In short circuit GMAW welding, an increase in inductance will decrease the number of short circuit
transfers per second (provided no other changes are made) and increase the arc-on time. The
increased arc-on time makes the welding puddle more fluid.
MIG
CV weld process with individual settings of voltage and wire speed.
MWCI
Manual Weld Control Interface. A separate remote user interface dedicated to providing arc data
monitoring near the operator’s location. This interface provides the operator with the ability to start a
new part, join welds, or ignore welds. The MWCI has a display for error read-outs and status LEDs.
Preflow
Setting a time value for gas flow prior to arc start.
Postflow
Setting a time value for gas flow after arc end.
Process
A selection made for MIG, Pulse, and Accu-pulse.
Process Set Up
Selection procedure for entering program.
Program
Eight active slots for selection of various processes, wire type, and parameters.
Program Load
Enters selected program information into program slot.
Pulse
Conventional pulse program using peak, background, pulse width, frequency, and peak voltage as
factory taught data. Adaptive method is controlled by frequency adjustment.
Retract
Sequence function that allows the wire to move back towards the contact tip when a welding
operation is completed. Setting is both speed (IPM) and time (sec).
RMD (optional)
RMD refers to Regulated Metal Deposition. A precisely controlled short-circuit transfer. Benefits of
RMD are well suited to thin materials, improves gap filling and spatter reduction. Provides less heat
input into workpiece, minimizes distortion and allows use of larger diameter wire on thin gauge
materials.
Sequence
Selecting Sequence will allow setting of preflow, start, crater, and postflow times and parameters.
Slope
Slope refers to the shape of a volt-amp curve. Varying the amount of slope in the welding circuit will
change the amount of short-circuit current and rate of response from the welding power source.
Start
Provides voltage/arc adjust, wire feed rate, and time value for modified arc starts.
TDS (Trigger Dual Schedule)
TDS allows the operator to select between a pair of weld programs by using the gun trigger. In TDS
mode, momentarily release and close the gun trigger while welding to cycle between a pair of
preselected weld programs.
Содержание Axcess E 300
Страница 14: ...OM 244 814 Page 10 ...
Страница 18: ...OM 244 814 Page 14 Notes ...
Страница 22: ...OM 244 814 Page 18 Notes ...
Страница 26: ...OM 244 814 Page 22 Notes ...
Страница 30: ...OM 244 814 Page 26 Notes ...
Страница 56: ...OM 244 814 Page 52 Notes ...
Страница 63: ...Trouble OM 244 814 Page 59 Notes ...
Страница 68: ...OM 244 814 Page 64 Figure 14 2 Circuit Diagram For Axcess E 300 2 Of 2 ...
Страница 69: ...Circuits OM 244 814 Page 65 248 763 E Part 2 Of 2 ...
Страница 70: ...OM 244 814 Page 66 Figure 14 3 Circuit Diagram For Axcess E 450 1 Of 2 ...
Страница 71: ...Circuits OM 244 814 Page 67 245 131 F Part 1 Of 2 ...
Страница 72: ...OM 244 814 Page 68 Figure 14 4 Circuit Diagram For Axcess E 450 2 Of 2 ...
Страница 73: ...Circuits OM 244 814 Page 69 245 131 F Part 2 Of 2 ...
Страница 74: ...OM 244 814 Page 70 Figure 14 5 Circuit Diagram For Axcess E 675 1 Of 2 ...
Страница 75: ...Circuits OM 244 814 Page 71 250 570 C Part 1 Of 2 ...
Страница 76: ...OM 244 814 Page 72 Figure 14 6 Circuit Diagram For Axcess E 675 2 Of 2 ...
Страница 77: ...Circuits OM 244 814 Page 73 250 570 C Part 2 Of 2 ...
Страница 78: ...OM 244 814 Page 74 Figure 14 7 Circuit Diagram For Axcess E Module ...
Страница 79: ...Circuits OM 244 814 Page 75 250 571 C ...
Страница 80: ...OM 244 814 Page 76 Notes ...
Страница 106: ...Notes ...