Miller 261970 Скачать руководство пользователя страница 1

®

CoolBand

t

II Integrated

OM-262 902A

2013−09

To help us serve you better, go to MillerWelds.com/CoolerNow

Headgear Cooling System

Содержание 261970

Страница 1: ...CoolBandtII Integrated OM 262 902A 2013 09 To help us serve you better go to MillerWelds com CoolerNow Headgear Cooling System...

Страница 2: ...BEFORE USING 1 1 1 Symbol Usage 1 1 2 Hazards 2 1 3 Proposition 65 Warnings 4 1 4 Principal Safety Standards 4 SECTION 2 BATTERY SAFETY PRECAUTIONS READ BEFORE USING 5 2 1 Symbol Usage 5 2 2 Hazards...

Страница 3: ...Installing The Battery 18 3 6 Installing The Filter 19 3 7 Removing Air Deflector To Adjust Air Flow 20 3 8 Operating The Controls 22 3 9 Checking Headgear Cooling Sys Before Use 24 SECTION 4 MAINTENA...

Страница 4: ......

Страница 5: ...onsult symbols and related instructions below for necessary actions to avoid the hazards Indicates special instructions DANGER Indicates a hazard ous situation which if not avoided will result in deat...

Страница 6: ...these fumes and gases can be hazardous to your health D Read and follow these instructions and the safety labels carefully This product is intended for use as a cooling device only It is not a respira...

Страница 7: ...ed working properly and properly worn D Before each use inspect the equipment for damage and verify it operates prop erly D Dangerous contaminants may not smell or be visible Leave the area immedi ate...

Страница 8: ...birth defects or other reproductive harm Wash hands after use 1 4 Principal Safety Standards Safety in Welding Cutting and Allied Processes ANSI Standard Z49 1 is available as a free download from the...

Страница 9: ...lt symbols and related instructions below for necessary actions to avoid the hazards Indicates special instructions DANGER Indicates a hazard ous situation which if not avoided will result in death or...

Страница 10: ...and skin immediately with water READ INSTRUCTIONS D Read and follow all labels and the Owner s Manual carefully before before using the battery or battery charger Read the safety information at the be...

Страница 11: ...rage information D Keep battery away from fire out of direct sunlight and away from other sources of heat D Do not use or charge the battery if it has been dropped or damaged D Do not open puncture re...

Страница 12: ...birth defects or other reproductive harm Wash hands after use 2 4 Principal Safety Standards Safety in Welding Cutting and Allied Processes ANSI Standard Z49 1 is available as a free download from the...

Страница 13: ...tory protection equipment required consult your safety director and an Industrial Hygienist Use the cooling system only with compatible Miller welding helmets MP 10t Pro Hobbyt Performancet Elitet Tit...

Страница 14: ...OM 262 902 Page 11 To better show components and fea tures the headgear cooling system is shown without welding helmet...

Страница 15: ...not provide respiratory protection NOTICE Operating cooling system without a filter will damage fan motor and void warranty Operating Temperature 14 to 131 F 10 to 55 C Storage Temperature For Up To S...

Страница 16: ...tery retains about 80 of original battery life after 300 charges Battery may be recharged about 500 times Cowl Head Shroud Service Life Replace After 50 Washings Battery Charger Input 100 240 VAC 4 5W...

Страница 17: ...nob 2 O Ring 3 Washer Remove knobs o rings and washers from hel met headgear Remove helmet headgear Install cooling system headgear and secure with knobs o rings and washers Retain old headgear for fu...

Страница 18: ...no gaps between shroud and helmet edge 1 Cowl Head Shroud 2 Knob 3 Shroud Slots Slide slots on right and left side of shroud over knobs Stretch shroud over helmet Shroud must be used when cooling syst...

Страница 19: ...OM 262 902 Page 16 Notes...

Страница 20: ...OM 262 902 Page 17 3 4 Charging The Battery 1 2 3 4...

Страница 21: ...e tape from battery terminals before charging bat tery 1 Battery 2 Battery Charger 3 120 Volt 15 A AC Receptacle Remove battery from blower assembly see Section 3 5 Extend prongs on back of charger an...

Страница 22: ...from fire or heat To better show components and features the headgear cooling system is shown without welding helmet 1 Access Door 2 Battery Open battery access door Slide battery into blower assembly...

Страница 23: ...cooling system without a filter will damage fan motor and void warranty Filter is required for proper opera tion of equipment but does not provide respiratory protection 1 Filter Cover 2 Filter 3 Fing...

Страница 24: ...oving Air Deflector To Adjust Air Flow 1 Air Deflector 2 Manifold D With air deflector installed air is directed to upper part of face D Remove deflector to direct air to lower part of face Save air d...

Страница 25: ...OM 262 902 Page 22 Notes...

Страница 26: ...industrial hygienist test the air in your facility to determine if respiratory protection is required to provide adequate protection from contaminants in your environment With cooling system equipped...

Страница 27: ...To Stop Press Power button again Use light pressure on Power button to turn unit off 2 Battery Level Light When powered up light turns on green for two seconds and then flash es once per second as lo...

Страница 28: ...e an industrial hygienist test the air in your facility to determine if respiratory protection is required to pro vide adequate protection from contaminants in your environment With cooling system equ...

Страница 29: ...ower assembly 2 Flexible Tube Be sure the tube is undam aged and properly con nected to the manifold and blower assembly 3 Battery Verify the battery is fully charged and secured in the battery compar...

Страница 30: ...OM 262 902 Page 27 SECTION 4 MAINTENANCE 4 1 Adjusting Headgear 1 2 3 4 5...

Страница 31: ...or right to desired tight ness 3 Distance Adjust ment Adjusts the distance be tween the face and the lens To adjust press tabs and slide forward or back to desired position Release tabs Both sides mu...

Страница 32: ...fold Tab Push in and up 3 Manifold Bracket With both side tabs free slide manifold bracket to right side and pull straight away from front of head band Remove fabric head band and clean or re place R...

Страница 33: ...after each use Use a soft cloth dampened with a mild soap and water solution to wipe all external surfaces clean Allow to air dry Product usage workplace contamination levels and other factors affect...

Страница 34: ...ge from blower assembly outlet and tube Blower assembly runs for short time even though battery is fully charged Be sure battery is properly connected to battery charger Replace battery Replace charge...

Страница 35: ...er and replace filter if necessary Check flexible tube connection to blower assembly and manifold Have Safety Director and an Industrial Hygienist deter mine if you are using the proper equipment for...

Страница 36: ...OM 262 902 Page 33 SECTION 5 PARTS LIST 1 2 4 5 6 7 8 9 10 11 3 13 12 Figure 5 1 CoolBand Headgear Cooling System...

Страница 37: ...roud Head 1 3 261975 Tubing Stretch 1 4 243930 Deflector Air 1 5 261972 Manifold 1 6 261973 Bracket Manifold 1 7 770249 Headband Fabric 1 8 261974 Headgear Set Includes Knobs Springs Headbands Mountin...

Страница 38: ...RANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EX PRESS OR IMPLIED INCLUDING THE WARRANTIES OR MER CHANTABILITY AND FITNESS The headgear cooling system is warranted for one year from the date of p...

Страница 39: ......

Страница 40: ...Visit our website at www MillerWelds com Miller Electric Mfg Co An Illinois Tool Works Company 1635 West Spencer Street Appleton WI 54914 USA ORIGINAL INSTRUCTIONS 2013 Miller Electric Mfg Co...

Отзывы: