Страница 1: ...e safety material throughout both manuals before installing operating or maintaining this equipment This unit and these instructions are for use only by persons trained and experienced in the safe ope...

Страница 2: ...teries 6 months provided that MILLER is notified in writing within thirty 30 days of the date of such failure As a matter of general policy only MILLER may honor claims submitted by the original user...

Страница 3: ...Electric Shock 1 1 2 Provide Protection From Fumes And Gases 1 1 3 Protect Eyes And Skin From Arc Rays Protect Ears From Noise 1 1 4 Prevent Fires And Burns 1 1 5 Protect Compressed Gas Cylinders 1 1...

Страница 4: ......

Страница 5: ...roperly install and ground the welding power 5 For additional information refer to NFPA Stan source according to its Owners Manual and all dard 51 B Fire Prevention in Use of Cutting and applicable co...

Страница 6: ...welding equipment sup plier For your protection read and comply with the latest editions of the following standards 1 ANSI Standard Z49 t available from the Ameri can Welding Society 550 N W LeJeune...

Страница 7: ...damage to this equipment IMPORTANT statements identify special instructions necessary for the most efficient operation of this equip ment SECTION 3 SPECIFICATIONS Table 3 1 Specifications Model Amper...

Страница 8: ...1 Install collet slotted end last into collet body 2 Install collet body and collet into torch body making sure heat shield is in place 3 Install properly prepared tungsten electrode see Section 6 2 i...

Страница 9: ...des a gas valve connect a suitable length of gas hose extra hose not supplied from power cable adapter to regulator flowmeter see Figure 4 2 If torch is without gas valve connect a suitable length of...

Страница 10: ...NOISE can damage hearing Wear correct eye ear and body protection FUMES AND GASES can seriously harm your health Keep your head out of the fumes Ventilate to keep from breathing fumes and gases If ve...

Страница 11: ...aks in insulation and ensure that all connections are clean and tight Repair or replace cables if insulation breaks are present Clean and tight en connections at each inspection 6 2 TUNGSTEN ELECTRODE...

Страница 12: ...020 Uptol5 5 20 Uptol5 5 20 UptolO 10 20 040 15 80 10 60 20 30 1 16 70 150 10 20 50 100 30 80 3 32 125 225 15 30 100 160 60 130 1 8 225 360 25 40 150 210 100 180 5 32 360 450 40 55 200 275 160 240 3...

Страница 13: ...stributor CUP see Fig 7 2 COLLET BODY see Fig 7 2 COLLET see Fig 7 2 HEAT SHIELD 1 1 6 116540 TORCH BODY 1 6 116557 TORCH BODY 1 6 7 8 116 556 116 255 116254 100VK 100R TORCH BODY with valve consistin...

Страница 14: ...shield Stock No 119 887 For Gas Lens Alumina Cup 1 Long Stock Model No Cup Orifice 119 893 2AG4 1 4 119 894 2AG5 5 16 119 895 2AG6 3 8 119896 2AG7 7 16 CROSS REFERENCE TO COMPETITIVE MODEL STOCK NO MO...

Страница 15: ......

Страница 16: ...g RMC H14 S Momentary 129 336 RLC H14 S Locking 129 335 Note Cannot be used on torch with manual gas valve For field installa tion only replaces standard torch handle TIG HOSE HOOK UP KITS THK THK 2 a...