background image

Содержание GPS-1000

Страница 1: ...talling operating or maintaining this equip ment This unit and these instructions are for use only by persons trained and experienced in the safe operation of welding equipment Do not allow un trained...

Страница 2: ...lacement or where authorized in writing by Miller in appropriate cases 3 the reasonable cost of repair or replacement at an authorized Miller service station or 4 payment of or credit for the purchase...

Страница 3: ...ion Quantity 2 1 2 4 2 059 572 004 104 004259 120 496 099 044 048599 PLATE adapter power cord CONTACTOR 3P 110 120 220 240 Eff w JH282902 COIL 1 1 1 2 004 258 Deleted 4 27 009 139 Deleted 4 601 375 De...

Страница 4: ......

Страница 5: ...Receiving Handling 13 2 3 Description 13 2 4 Safety 13 SECTION 3 INSTALLATION 3 1 Location 13 3 2 Electrical Input Connections 14 3 3 Weld Output Connections 15 SECTION 4 OPERATION 4 1 Power Control...

Страница 6: ......

Страница 7: ...1 1 INTRODUCTION Contrairement a lappren tissage de Ia vie lapprentissage de Ia s curit par ox p rience personnelle comme lenfant qui touche un po le chaud est dangereux imprudent at inutile lnstruise...

Страница 8: ...rre protecteur lorsquil est bris piqu ou quil a recu des projections Voir 1 3A 2 Evitez de porter des habits impregn s dhuile ou de graisse Une tincelle pourrait les enflammer Ne manipulez jamais sans...

Страница 9: ...on sont les com bustibles atteints par arc Ia flamme les tincelles le laitier chaud ou los mat rlaux chauff s le mauvais emplol des gaz comprim s et des bouteilles ainsi que los courts circuits Sachez...

Страница 10: ...te peut tre remplac e par un niveau deau arrivant au dessous du travail a effectuer Vous dovez layer un recipient dont Ia nature de contenu est inconnue voir paragraphe ci dessus NE vous fiez PAS a Io...

Страница 11: ...ature du gaz Adressez vous a votre fournisseur si cola nest pas indique NEFFACEZ ou ne modifiez JAMAIS los noms num ros ou autres indications sur une bouteille Cela est illegal et dangereux Vides Main...

Страница 12: ...pez Ia partie perc e ou us e et rac cordez 1 2D3 NUTILISEZ JAMAIS de ruban adh sif 4 Branchements corrects Avant de brancher be d tendeur nettoyez Ia sortie du robinet do Ia bouteille des impuret s qu...

Страница 13: ...du manuel de Iappareil F Appareil laiss sans surveillance Fermez lalimentation do gaz a Ia source et purgez G Liens at supports temporairos Pour vos travaux do soudage ou do coupaga nutilisez pas do...

Страница 14: ...raux sous le masque pour prot ger les yeux dans le cas o le masque ne serait pas abaiss sur le visage avant lamorcage de larc Regarder momentan ment un arc sans protection principalement un arc en atm...

Страница 15: ...arges lectriques maintenez votre corps et v tements secs Ne travaillez jamais dans un endroit humide sans isolation adequate contre les d charges lectriques Lorsque vous no pouvez viter thumidit ou Ia...

Страница 16: ...fr quemment lusure las fissures et lalt ration des cables REMPLACEZ IMMEDIATEMENT ceux dont lisolation serait trop us e ou alt r e pour pr venir los d charges mortelles provoqu es par un cable d nud...

Страница 17: ...Standard 51 B CUTTING AND WELDING PROCESSES obtainable from the National Fire Protection Association 470 Atlantic Avenue Boston MA 02210 Linterrupteur darr t doit toujours se trouver a prox imit de Ia...

Страница 18: ...ry Protection obtainable from the American Na tional Standards Institute 1430 Broadway New York NY 10018 11 CGA Pamphlet P i SAFE HANDLING OF COM PRESSED GASES IN CYLINDERS distribu par Ia Compressed...

Страница 19: ...e front of this manual should be read completely This will help avoid possible injury due to misuse or im proper welding applications The following definitions apply to CAUTION IMPOR TANT and NOTE blo...

Страница 20: ...thers that the circuit is being worked on Insert the three input conductors plus one ground con ductor through the access hole on the rear panel This hole will accept standard conduit fittings See Fig...

Страница 21: ...with this unit the steps listed should be followed to ensure the best welding performance r ii iO 0 I I lou L J Li 1 r 101 iO i I I I I I I I I I 101 0 J IQu L I I 101 I I 0 0 101 L_J L_ IMPORTANT __...

Страница 22: ...etween the B Positive and B Negative output terminals TA084 430 When the weld output terminals are bused together 1500 amperes of weld output is available between the A Positive and A Negative or B Po...

Страница 23: ...y to weld status should this circuit breaker trip the circuit breaker should be manually reset Should the circuit breaker continue to trip after each reset an internal problem in the circuitry is most...

Страница 24: ...it and the amount of dust and dirt in the atmosphere The welding power source outer enclosure should be removed and a clean dry air stream or vacuum suction should be used for this cleaning operation...

Страница 25: ...TE L 0 LI I D Figure 6 2 Circuit Diagram For 1500A Models Circuit Diagram No B 088 038 A OM 267 Page 19 rivE NEGATIVE B Circuit Diagram No B 086 792 Figure 6 1 Circuit Diagram For 1000 Models...

Страница 26: ...Circuit Diagram No B 088 039 L 0 i 0 Figure 6 3 Circuit Diagram For 1500V Models OM 267 Page 20...

Страница 27: ...PARTS LIST November1986 FORM OM 267E Effective With Serial No JF887698...

Страница 28: ...OM 267 Page 1 Figure A Left Side View...

Страница 29: ...500 volts 6 6 037 156 DIODE rectifier 275 amp 250 volts straight polarity 18 18 All 085 295 RESISTOR WWfixed5watt2000 ohm 1 1 1 VR 035 645 VAR ISTOR 8 joule 150 volts 6 6 6 8 V1 2 025 638 METER volts...

Страница 30: ...0 4 DC CD C I cD CO Cl 0 CD CD 0 I P 4 Co C 3...

Страница 31: ...l block 30 amp 2 1 038 602 BLOCK terminal 30 amp 3 pole 460 575 1 Ri 083 640 RESISTOR grid 1 1 1 30 083 637 WINDTUNNEL 20 inch 1 1 1 014 425 BAR support windtunnel 2 2 2 31 032 616 BLADE fan 60 Hz 20...

Страница 32: ......