background image

OWNER’S MANUAL

©

 2009 MILLER Electric Mfg. Co.

OM-235 464E

2009

10

CE And Non-CE Models

Coolmate

 1

1.

Safety Symbol Definitions

DANGER! 

 Indicates a hazardous situation which, if not

avoided, will result in death or serious injury. The possible

hazards are shown in the adjoining symbols or explained

in the text.

DANGER! 

 

Indique une situation dangereuse qui si on

l’évite pas peut donner la mort ou des blessures graves.

Les dangers possibles sont montrés par les symboles

joints ou sont expliqués dans le texte.

Wear safety glasses with side shields.
Porter des lunettes de sécurité avec des protections laté-

rales.

Indicates a hazardous situation which, if not avoided,

could result in death or serious injury

The possible ha-

zards are shown in the adjoining symbols or explained in

the text.
Indique une situation dangereuse qui si on l’évite pas peut

donner la mort ou des blessures graves. Les dangers possi-

bles sont montrés par les symboles joints ou sont expliqués

dans le texte.

Have only trained and qualified persons install, operate,

or service this unit. Call your distributor if you do not un-

derstand the directions. For WELDING SAFETY and

EMF information, read owner’s manual(s).
L’installation, l’exploitation et l’entretien de cet appareil

doivent être confiés uniquement à des personnes quali-

fiées et convenablement formées. S’adresser à un distri-

buteur si l’on ne comprend pas les directives. Pour les

renseignements ayant trait à la SECURITE lors du sou-

dage et  aux champs électromagnétiques, consulter les

manuels traitant les dévidoirs et les sources de courant

pour le soudage.

NOTICE

Indicates statements not related to personal injury.
Indique des déclarations pas en relation avec des blessu-

res personnelles.
Indicates special instructions.
Indique des instructions spécifiques.

Beware of moving parts. Keep guards and panels in

place, covers closed, and hands away from moving parts.
Attention aux pièces mobiles. Maintenir les dispositifs de

sécurité et les panneaux en place, les couvercles fermés

et garder les mains éloignées des pièces mobiles.

Beware of electric shock from wiring. Reinstall all panels

and covers.
Risque d’électrocution due au contact avec des fils. Réin-

staller tous les panneaux et couvercles.

Recycle or dispose of used coolant in an environmentally

safe way.
Recycler ou éliminer tout liquide de refroidissement usé

conformément aux méthodes prescrites pour assurer la

protection de l’environnement.

2.

EMF Information

Electric current flowing through any conductor causes localized elec-

tric and magnetic fields (EMF). Welding current creates an EMF field

around the welding circuit and welding equipment. EMF fields may in-

terfere with some medical implants, e.g. pacemakers. Protective

measures for persons wearing medical implants have to be taken. For

example, access restrictions for passers

by or individual risk assess-

ment for welders. All welders should use the following procedures in

order to minimize exposure to EMF fields from the welding circuit:

1. Keep cables close together by twisting or taping them, or using

a cable cover.

2. Do not place your body between welding cables. Arrange

cables to one side and away from the operator.

3. Do not coil or drape cables around your body.

4. Keep head and trunk as far away from the equipment in the

welding circuit as possible.

5. Connect work clamp to workpiece as close to the weld as

possible.

6. Do not work next to, sit or lean on the welding power source.

7. Do not weld whilst carrying the welding power source or wire

feeder.

About Implanted Medical Devices:

Implanted Medical Device wearers should consult their doctor and the

device manufacturer before performing or going near arc welding,

spot welding, gouging, plasma arc cutting, or induction heating opera-

tions. If cleared by your doctor, then following the above procedures

is recommended.

3.

Important Information Regarding CE Products (Sold Within The EU)

!

This equipment shall not be used by the general public as the EMF  limits for the general public might be exceeded during welding.

This equipment is built in accordance with EN 60974

1 and is intended to be used only in an occupational environment (where the general public

access is prohibited or regulated in such a way as to be similar to occupational use) by an expert or an instructed person.
Wire feeders and ancillary equipment (such as torches, liquid cooling systems and arc striking and stabilizing devices) as part of the welding

circuit may not be a major contributor to the EMF. See the Owner’s Manuals for all components of the welding circuit for additional EMF exposure

information.

S

The EMF assessment on this equipment was conducted at 0.5 meter.

S

At a distance of 1 meter the EMF exposure values were less than 20% of the permissible values.

Содержание Coolmate 1 CE

Страница 1: ...y safe way Recycler ou liminer tout liquide de refroidissement us conform ment aux m thodes prescrites pour assurer la protection de l environnement 2 EMF Information Electric current flowing through...

Страница 2: ...40 C above ambient temper ature at a 1L min flow rate Max Welding Amperage Rating 200 amps 40 duty cycle 175 amps 60 duty cycle 150 amps 100 duty cycle Dimensions 23 3 4 in 603 mm Long 7 1 2 in 191 m...

Страница 3: ...on 8 Recycle or dispose of used coolant in an environmentally safe way 9 Do not remove or paint over cover the label 4 96 S 178 910 043 810 HF 043 809 AL 100 h std 2 1 3 6 4 7 5 1 Warning Watch Out Th...

Страница 4: ...acility Contact your local recycling office or your local distributor for further information 9 Coolant Chart Low Conductivity Coolant No 043 810 Distilled Or Deionized Water OK Above 32 F 0 C Low Con...

Страница 5: ...t tempt to rewire for 115 volts For 115 volt models an individual branch circuit capable of carrying 15 amperes and protected by fuses or circuit breakers is recommended Recommended fuse or cir cuit b...

Страница 6: ...cut plug from 230 volt cord and at tempt to rewire for 115 volts An individual branch circuit capable of car rying 15 amperes and protected by fuses or circuit breakers is recommended Rec ommended fu...

Страница 7: ...t input power be fore maintaining NOTICE Do not run cooler with out coolant in tank 1 Coolant Filter Unscrew housing to clean filter see Section 12 Assemble and install cleaned cool ant filter Dispose...

Страница 8: ...r mid plane Coolant system does not work Be sure input power cord is plugged into an energized receptacle and power is turned on Check line fuses or circuit breaker and replace or reset if necessary M...

Страница 9: ...OM 235 464 Page 9 Notes...

Страница 10: ...4 Page 10 SECTION 16 PARTS LIST Hardware is common and not available unless listed 805 266 A 1 2 3 4 5 13 6 8 7 12 9 10 12 11 13 6 15 14 13 6 14 18 17 21 22 23 24 18 26 25 20 19 16 27 Figure 16 1 Main...

Страница 11: ...Rbr Brd No 1 X 375 ID X 9 0 Black 1 15 235461 Damper Fluid Pulsation 1 16 MOT 235457 Pump Assy Coolant 115V 1 16 MOT 235501 Pump Assy Coolant 230V 1 17 PLG1 192457 Cable Power 11 Ft 7 In 16ga 3c 115V...

Страница 12: ...mpatibility Standards S IEC 60974 1 2005 Arc welding equipment Part 1 Welding power sources S IEC 60974 2 2008 Arc welding equipment Part 2 Liquid cooling systems S IEC 60974 10 2007 Arc Welding Equip...

Страница 13: ...Notes...

Страница 14: ...Notes...

Страница 15: ...Notes Work like a Pro Pros weld and cut safely Read the safety rules at the beginning of this manual...

Страница 16: ...your personal records Always provide Model Name and Serial Style Number Contact a DISTRIBUTOR or SERVICE AGENCY near you Welding Supplies and Consumables Options and Accessories Personal Safety Equip...

Отзывы: