Miller Electric 714S Скачать руководство пользователя страница 12

OM-1500-4 Page 8

1-4.

Principales normes de sécurité

Safety in Welding and Cutting, norme ANSI Z49.1, de l’American Wel-
ding Society, 550 N.W. Lejeune Rd, Miami FL 33126

Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent
of Documents, U.S. Government Printing Office, Washington, D.C.
20402.

Recommended Safe Practice for the Preparation for Welding and Cut-
ting of Containers That Have Held Hazardous Substances,
 norme AWS
F4.1, de l’American Welding Society, 550 N.W. Lejeune Rd, Miami FL
33126

National Electrical Code, NFPA Standard 70, de la National Fire Protec-
tion Association, Batterymarch Park, Quincy, MA 02269.

Safe Handling of Compressed Gases in Cylinders, CGA Pamphlet P-1,
de la Compressed Gas Association, 1235 Jefferson Davis Highway,
Suite 501, Arlington, VA 22202.

Règles de sécurité en soudage, coupage et procédés connexes, norme
CSA W117.2, de l’Association canadienne de normalisation, vente de
normes, 178 Rexdale Boulevard, Rexdale (Ontario) Canada M9W 1R3.

Safe Practices For Occupation And Educational Eye And Face Protec-
tion
, norme ANSI Z87.1, de l’American National Standards Institute,
1430 Broadway, New York, NY 10018.

Cutting and Welding Processes, norme NFPA 51B, de la National Fire
Protection Association, Batterymarch Park, Quincy, MA 02269.

1-5.

Information sur les champs électromagnétiques

Données sur le soudage électrique et sur les effets, pour l’organisme,
des champs magnétiques basse fréquence

Le courant de soudage, pendant son passage dans les câbles de sou-
dage, causera des champs électromagnétiques. Il y a eu et il y a encore
un certain souci à propos de tels champs. Cependant, après avoir ex-
aminé plus de 500 études qui ont été faites pendant une période de
recherche de 17 ans, un comité spécial ruban bleu du National Re-
search Council a conclu: “L’accumulation de preuves, suivant le
jugement du comité, n’a pas démontré que l’exposition aux champs
magnétiques et champs électriques à haute fréquence représente un
risque à la santé humaine”. Toutefois, des études sont toujours en cours
et les preuves continuent à être examinées. En attendant que les con-
clusions finales de la recherche soient établies, il vous serait
souhaitable de réduire votre exposition aux champs électromagnéti-
ques pendant le soudage ou le coupage.

Afin de réduire les champs électromagnétiques dans l’environnement
de travail, respecter les consignes suivantes :

1

Garder les câbles ensembles en les torsadant ou en les
attachant avec du ruban adhésif.

2

Mettre tous les câbles du côté opposé de l’opérateur.

3

Ne pas courber pas et ne pas entourer pas les câbles autour de
votre corps.

4

Garder le poste de soudage et les câbles le plus loin possible de
vous.

5

Relier la pince de masse le plus près possible de la zone de
soudure.

Consignes relatives aux stimulateurs cardiaques :

Les personnes qui portent un stimulateur cardiaque doivent avant tout
consulter leur docteur. Si vous êtes déclaré apte par votre docteur, il est
alors recommandé de respecter les consignes ci–dessus.

Содержание 714S

Страница 1: ...Visit our website at www MillerWelds com 714S Processes Description MIG GMAW Welding Flux Cored FCAW Welding Gas And Self Shielded Wire Feeder OM 1500 4 203 211 June 2001...

Страница 2: ...alue established in 1929 This Owner s Manual is designed to help you get the most out of your Miller products Please take time to read the Safety precautions They will help you protect yourself agains...

Страница 3: ...nitions 9 SECTION 3 INSTALLATION 10 3 1 Site Selection 10 3 2 Rear Panel Connections And Rotating Drive Assembly 11 3 3 14 Pin Plug Information 12 3 4 Gun Recommendation Table 12 3 5 Wire Type Size An...

Страница 4: ......

Страница 5: ...that cord plug is connected to a properly grounded receptacle outlet D When making input connections attach proper grounding conduc tor first double check connections D Frequently inspect input power...

Страница 6: ...elding wire at contact tip when not in use D Wear oil free protective garments such as leather gloves heavy shirt cuffless trousers high shoes and a cap D Remove any combustibles such as a butane ligh...

Страница 7: ...maintained D Keep high frequency source doors and panels tightly shut keep spark gaps at correct setting and use grounding and shielding to minimize the possibility of interference ARC WELDING can cau...

Страница 8: ...is a human health hazard However studies are still going forth and evidence continues to be examined Until the final conclusions of the research are reached you may wish to minimize your exposure to e...

Страница 9: ...ntation est bien raccord la borne de terre du sectionneur ou que la fiche du cordon est raccord e une prise correctement mise la terre D En effectuant les raccordements d entr e fixer d abord le condu...

Страница 10: ...er des v tements de protection d pourvus d huile tels que des gants en cuir une chemise en mat riau lourd des pantalons sans re vers des chaussures hautes et un couvre chef D Avant de souder retirer t...

Страница 11: ...vrements et dispositifs de protection LE RAYONNEMENT HAUTE FR QUENCE H F risque de provoquer des interf rences D Le rayonnement haute frequence peut provoquer des interf rences avec les quipements de...

Страница 12: ...champs magn tiques basse fr quence Le courant de soudage pendant son passage dans les c bles de sou dage causera des champs lectromagn tiques Il y a eu et il y a encore un certain souci propos de tel...

Страница 13: ...o 1 8 in 0 6 To 3 2 mm Max Spool Weight 60 lb 27 kg 100 Volts 750 Amperes 100 Duty Cycle IP 21 Length 27 in 686 mm Width 12 1 2 in 318 mm Height 14 in 356 mm 58 lb 26 kg 2 2 Symbols And Definitions So...

Страница 14: ...welding power source 3 Wire Spool Reel 4 Gas Cylinder w Hose And Re gualtor Customer Supplied 5 Welding Power Source 6 Running Gear Y Do not put feeder where welding wire hits cylinder Y Do not move...

Страница 15: ...ding Gas Valve Fitting Requires fitting with 5 8 18 right hand threads Connect customer supplied gas hose 3 Weld Cable Terminal 4 Weld Cable 5 Drive Assembly 6 Drive Assembly Rotation Knob To rotate t...

Страница 16: ...to 10 volts dc 1 volt per 10 arc volts F Current feedback 0 to 10 volts dc 1 volt per 100 amperes The remaining pins are not used 3 4 Gun Recommendation Table Process Gun GMAW Hard or Cored Wires Roug...

Страница 17: ...all diameter stainless steel wire reduce drive roll pressure on the rear roll to half that of the front rolls To adjust drive roll pressure hold nozzle about 2 in 51 mm from nonconductive surface and...

Страница 18: ...d PC1 w Setting Current Detect Override S1 1 Current detect override is used to disable automatic run in when a welding power source is used that doesn t provide current feedback through the 14 pin re...

Страница 19: ...Switch Settings 1 2 3 4 5 Or Or High Speed Motor Meters Minute High Speed Motor Inches Minute Standard Motor Meters Minute Standard Motor Inches Minute Digital Meter Functions 1 2 3 4 5 1 2 3 4 5 1 2...

Страница 20: ...n trigger is still activated after two minutes the jog opera tion is terminated to prevent complete des pooling of the wire as in the case of a dam aged gun Despooling protection is not available if c...

Страница 21: ...welding press the trigger again 1 802 828 A 4 4 Optional Voltage Control And Digital Meters 3 802 827 A 1 2 1 Voltmeter Displays actual or preset voltage from welding power source through the 14 pin...

Страница 22: ...aintaining 3 Months Replace unreadable labels Clean and tighten weld terminals Repair or replace cracked weld cable Check 14 pin cord Check gas hose and fittings Check gun cable Replace cracked parts...

Страница 23: ...he trigger held for more than two minutes with out striking an arc providing current over ride is not enabled or if the user holds the trigger past the postflow phase in a timed weld This error also o...

Страница 24: ...OM 1500 4 Page 20 Notes...

Страница 25: ...OM 1500 4 Page 21 SECTION 6 ELECTRICAL DIAGRAM Figure 6 1 Circuit Diagram 202 246...

Страница 26: ...OM 1500 4 Page 22 SECTION 7 PARTS LIST 802 943 Hardware is common and not available unless listed Fig 7 2 21 Fig 7 3 4 1 2 6 14 15 16 17 18 19 20 5 7 8 9 10 11 12 11 10 13 3 Figure 7 1 Main Assembly...

Страница 27: ...28 WASHER brake stl 2 12 058 428 HUB spool 1 13 135 205 NUT stl slflkg hex reg 625 11 w nylon insert 1 14 200 556 SUPPORT spool 1 15 201 781 KNOB w extension clamp 1 16 156 243 CLAMP motor top 1 17 14...

Страница 28: ...TRAIN RELIEF 1 7 079 739 CONN circ cpc clamp str rlf 1 8 PLG12 141 162 HOUSING PLUG PINS service kit 1 PLG3 115 093 HOUSING PLUG SKTS service kit 1 9 605 227 NUT 750 14 knurled1 68dia 41h nyl 1 10 200...

Страница 29: ...007 KNOB pointer 1 670 dia x 250 id w set screwsplstc 2 115 443 STAND OFF no 6 32 x 750 4 PLG7 67 115 091 HOUSING PLUG SKTS service kit 1 PLG9 201 665 HOUSING PLUG SKTS service kit 1 PLG11 61 131 055...

Страница 30: ...257 ID x 619 OD x 105 2 7 133 493 RING retaining ext 250 shaft x 025thk 2 8 133 350 PIN hinge 1 9 M1 201 230 MOTOR gear 1 8hp 24VDC standard speed 1 9 M1 201 231 MOTOR gear 1 8hp 24VDC high speed 1 15...

Страница 31: ...x 025thk 1 28 134 834 HOSE SAE 187 ID x 410 OD order by ft 2ft 29 149 959 FITTING brs barbed M 3 16tbg x 312 24 1 30 179 265 ADAPTER gun feeder 1 31 108 940 SCREW cap stl hexhd 250 20 x 750 4 32 604 5...

Страница 32: ...2 961 151 074 053 709 7 64 in 110 in 2 8 mm 151 042 053 705 132 962 151 075 053 711 151 059 1 8 in 125 in 3 2 mm 151 043 053 707 151 060 132 963 151 076 053 712 Fraction Metric Wire Size V GROOVE 4 Ro...

Страница 33: ...OM 1500 4 Page 29 Notes...

Страница 34: ...OM 1500 4 Page 30 Notes...

Страница 35: ...ting Torches Remote Controls Accessory Kits Replacement Parts No labor Spoolmate 185 Spoolmate 250 Canvas Covers Miller s True Blue Limited Warranty shall not apply to 1 Consumable components such as...

Страница 36: ...complete and retain with your personal records Always provide Model Name and Serial Style Number Call 1 800 4 A Miller or see our website at www MillerWelds com to locate a DISTRIBUTOR or SERVICE AGEN...

Отзывы: