background image

INSTALLATION INSTRUCTIONS 

 

RELAY LIGHT CURTAIN 

 

  

MODEL: RLC-K36, RLC-K72

 

 

 

 

 

 

www.milleredge.com [email protected]  800-220-3343 1/4 

WARNING

 

Read and understand all instructions before beginning installation. Disconnect power to motor and test upon completion. 

Photo optics should be installed by qualified personnel to ensure the requirements herein have been met. Keep these 

instructions with the installation. Always abide by local and national electrical code specifications when wiring accessories 

to motor controls. 

 

The Relay Light Curtain (RLC-K36, RLC-K72) is a non-monitored, fail-safe photo optic solution that has a normally 

open and a normally closed dry contact output. It provides additional protection for the area above the floor, 

protecting people and vehicles more effectively than a single-beam photo eye. Consult the manufacturer manual 

for detailed instructions about connecting RLC to the door operator. 

 

 

CONTENTS 

 

RLC-K36

: 3 ft., 8 elements 

o

 (1) Emitter 

o

 (1) Receiver 

o

 (4) Universal mounting 

brackets 

o

 (8) #4 ½ inch zinc plated oval 

head self-tapping screws 

 

 

RLC-K72:

 6 ft., 16 elements 

o

 (1) Emitter 

o

 (1) Receiver 

o

 (6) Universal mounting 

brackets 

o

 (12) #4 ½ inch zinc plated oval 

head self-tapping screws 

REQUIRED 

 Hand tools for installing brackets  

 

OPTIONAL 

 Alternative mounting hardware, as required  

 

SUGGESTED 

 Operator manual 

 

 

 

 

IMAGE 1: 

IMAGE 2:  

 

WIRING DIAGRAM 

UNIVERSAL MOUNTING BRACKETS 

 

RLC_INST_20210202 

For more information, please visit www.devancocanada.com or call toll free at 855-931-3334