background image

www.milleredge.com        [email protected]        800-220-3343

INSTALLATION  INSTRUCTIONS

Model: RB-G-K10

 

   

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED. 

READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION.

The Miller Edge RBand Monitored Gate Edge Transmitter/Receiver system is intended to provide a wireless 
connection between a monitored sensing edge and a motorized operator that controls the associated gate. RBand 
meets the 2016 UL 325 requirements for monitored devices and has been certified as a UL 325 Recognized 
Component. It is designed for use with operators that comply with 2016 UL 325 using a Miller Edge 10K Sensing 
Edge.

1.  PARTS LIST

Kit Contents:
1.  RBand Edge Transmitter (RB-TX10)
2.  RBand Gate Edge Receiver (RB-G-RX10)
3.  Receiver antenna
4.  (2) 3.6V AA lithium batteries*
5.  (4) #6 pan head transmitter mounting screws

*Replacement 

3.6V AA lithium batteries can be  

purchased at your local electronics store or via  
Miller Edge.

Required:
• 

1/8” flat blade screwdriver

• 

1/4” flat blade screwdriver

• 

Miller Edge 10K (T2/blue band) Sensing Edge  

• 

Coaxial cable for exterior mounted antenna 

• 

Coaxial bulkhead adapter, female/female

Recommended:
• 

Multi-meter capable of reading 10K

Ω

• 

Mounting screws for the Receiver

2.  RECEIVER: INSTALLATION

2-1.   Remove operator cover and turn off the power to the gate operator.
2-2.   Determine where to place the external mounted antenna so it is in line of sight with the Transmitter for the 

entire range of travel [IMAGE 1]. Prepare the antenna coax as necessary. 

2-3.  Remove Receiver cover and mount the base inside the operator, positioning it for optimum ease of wiring. 
2-4.  Connect power to the terminals marked 

12/24 AC/DC (polarity sensitive) on the removable 8-pin 

connector [IMAGE 2]. 

2-5.  Determine which monitored interface your operator uses. Connect the 

COM (C1/C2) and the correct output 

connections (

N.C. = CS1/CS2 or 10K = BS1/BS2) to your operator. There are 2 separate relays (channels): 

R1 and R2. The A Test terminals must be used for operators requiring N.C. inputs. Enable with DIP switch 4 
[TABLE 1].

2-6.  Replace the Receiver cover and turn on power to the operator. Note: it takes ~5 seconds for the Receiver to 

initialize. 

 

Note: RBand 10K Gate Edge Receiver is compatible with up to 3 RBand Transmitters on 2 channels (6 total).

RB-G-K10_Install_A4_20170706

IMAGE 1. RBand Transmitter Installation with Gate Edge

RBAND RECEIVER 

MOUNTED INSIDE OPERATOR  

WITH EXTERNAL ANTENNA

OPERATOR

ANTENNA

WIRING

RBAND TRANSMITTER  

MOUNTED NEAR 

SENSING EDGE

SENSING EDGE

Содержание RBAND

Страница 1: ...ommended Multi meter capable of reading 10KΩ Mounting screws for the Receiver 2 RECEIVER INSTALLATION 2 1 Remove operator cover and turn off the power to the gate operator 2 2 Determine where to place the external mounted antenna so it is in line of sight with the Transmitter for the entire range of travel IMAGE 1 Prepare the antenna coax as necessary 2 3 Remove Receiver cover and mount the base i...

Страница 2: ...OVABLE CONNECTORS For Normally Closed gate operators please reference page 5 8 PIN CONNECTOR Power 12 24 AC DC Constant power source 12 24 AC DC Constant power source ground Relay Output 1 CS1 N C monitored input C1 Monitored input Common BS1 10K monitored input Relay Output 2 CS2 N C monitored input C2 Monitored input Common BS2 10K monitored input 4 PIN CONNECTOR Relay Output 3 NO3 Low battery a...

Страница 3: ...oting the alignment pin IMAGE 3 4 2 Test the sensing edge for functionality 5 TROUBLESHOOTING If the Receiver does not react to the Transmitter you can check the RF signal strength 5 1 Press the check button on the Receiver for 2 seconds IMAGE 2 4 beeps will be heard You then will hear a beep every 1 1 2 seconds during the check process Wait about 30 seconds if no other beeps occur your system is ...

Страница 4: ...ditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This device complies with FCC radiation exposure limits for an uncontrolled environment This device shall be installed and operated with a minimum distance of 0 4 between users or bystanders and the device RBand Receiver Model RB...

Страница 5: ...ON COMMON MON 12 VDC ON 1 2 3 4 DIP Switch 4 Turn to on HySecurity CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC 24 VDC COMMON S1 S2 S3 SENSOR COM S1 S2 S3 SENSOR COM SENSOR COM 24 VDC ON 1 2 3 4 DIP Switch 4 On to run Off to test Not Sensor Common Maximum Controls CS1 C1 BS1 CS2 C2 BS2 NO3 C3 COM ATEST 12 24 AC DC 12 or 24 VDC GND EDGE 1 GND EDGE 2 GND GND 12 VDC ON 1 2 3 4 DIP Switch 4 Turn...