![Milestone Husky IVO Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/milestone/husky-ivo/husky-ivo_maintenance-manual_1795355030.webp)
Identify and replace a hard drive
If the RAID array status is
Degraded
in Husky Assistant
Storage management tab
, this article will help you
identify a faulty hard drive and rebuild the RAID configuration of your data storage.
If one of the hard drives fails, an audible alarm starts. After replacement of a faulty hard
drive, you have to manually start the rebuilding of the RAID.
Locate the hard drive tray with a status LED indicator code that shows a hard drive failure and get the drive
replaced.
Data hard drives status LED indicator codes
Condition
Flashes amber four times per second
Drive failure
Flashes green slowly
Drive rebuilding
Solid green
Drive online
RAID rebuild
To make the replaced hard drive available for the RAID array, rebuild the RAID:
1. Click
Manual configuration
to open MegaRAID Storage Manager.
You can use the MegaRAID Storage Manager for status, configuration, and maintenance of your data
storage RAID array.
2. On the
Remote servers
tab, click the IP address next to the host name.
Getting started and maintenance guide | Milestone Husky IVO™ 1000R
30 | Identify and replace a hard drive