background image

Regulatory Approvals

 

FCC Class A

 UL 

1950

 

CSA 22.2 No. 950

 EN60950
 CE
 

– EN55022 Class B

 – 

EN50082-1

Canadian EMI Notice

 

This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing  

 Equipment 

Regulations.

 

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel  

 

brouilleur du Canada.

European Notice

 

Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the  

 

Low Voltage Directive (73/23/EEC) issued by the commission of the European  Community.    

 

Compliance with these directives implies conformity to the following  European Norms:

 

EN55022 (CISPR 22) - Radio Frequency Interference

 

EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity

 

EN60950 (IEC950) - Product Safety

Trademarks:

 

The MiLAN logo and MiLAN Technology are registered trademarks of  MiLAN Technology 

       in the United States and/or other countries.

To Contact Technical Support:

 

For prompt response when calling for service, have the following information ready: 

 

 

- product serial number

 

 

- date of purchase

 

 

- vendor or place of purchase

 

You can reach MiLAN Technology technical support at: 

 

 

- Email: [email protected]

  

Telephone: 

+1.408.744.2775

 

 

- Fax: +1.408.744.2793 

 MiAN 

Technology

 

1329 Moffett Park Drive

 

Sunnyvale, CA 94089

 

United States of America

 Telephone: 

+1.408.744.2775

 Fax: 

+1.408.744.2793

 

http://www.milan.com

 [email protected]

Five-Year Limited Warranty

MiLAN Technology warrants to the original consumer or purchaser that each of its products, 
and all components thereof, will be free from defects in material and/or workmanship for a 
period of five years from the original factory shipment date. Any warranty hereunder is 
extended to the original consumer or purchaser and is not assignable.

 MiLAN Technology makes no express or implied warranties including, but not limited to, any 
implied warranty of merchantability or fitness for a particular purpose, except as expressly set 
forth in this warranty. In no event shall MiLAN Technology be liable for incidental or 
consequential damages, costs, or expenses arising out of or in connection with the 
performance of the product delivered hereunder. MiLAN Technology will in no case cover 
damages arising out of the product being used in a negligent fashion or manner.

MIL-185C/MIL-195C

ATM

 

 

 

TWIST

ATM Fiber/UTP Converter

© Copyright 2002 MiLAN Technology                 Printed in the USA                         P/N: 90000011 Rev. G

Ethernet

10BASE-FL

MDI

-X

/MDI

500mA

 Installation Guide MIL-185C/MIL-195C

UTP A

CTIVE

5VDC

 

FCC PART 15 CLASS A COMPLIANT

RX

TX

ATM Twist

 

Model: MIL 185 

 

UTP 

to 

Fiber 

 

ATM 

Multi-Mode 

CONVERTER

POWE

R

FIBER A

CTIVE

UTP A

CTIVE

UTP A

CTIVE

5VDC

 

FCC PART 15 CLASS A COMPLIANT

RX

TX

ATM Twist

 

Model: MIL 195 

 

UTP 

to 

Fiber 

 

ATM 

Single-Mode 

CONVERTER

POWE

R

FIBER A

CTIVE

UTP A

CTIVE

MIL-185C

MIL-195C

Installation Guide

This guide includes the following information:

     

 

 

"Introduction" on page 2

    

  

 

"Installation" on page 3

     

 

 

"Configuration Option" on page 4

     

 

 

"Specifications" on page 7

Содержание MIL-185C

Страница 1: ...ranty MiLAN Technology warrants to the original consumer or purchaser that each of its products and all components thereof will be free from defects in material and or workmanship for a period of five years from the original factory shipment date Any warranty hereunder is extended to the original consumer or purchaser and is not assignable MiLAN Technology makes no express or implied warranties in...

Страница 2: ... km for single mode fiber One SC type single mode MIL 195C or one SC type multi mode MIL 185C connector One shielded RJ 45 UTP connector External power supply Diagnostic LEDs Small form factor Operating Conditions Table 1 Recommended Operation Conditions Parameters Minimum Maximum Operating Temperature 5 C 40 C Humidity non condensing 10 95 Signal Output Load 35 ohm 75 ohm Supply Voltage 4 75 V 5 ...

Страница 3: ...X Transmit 3 Connect the power receptacle from the wall adapter to the unit 4 Verify that the power LED illuminates 5 Verify that both the UTP and the FIBER active LEDs also illuminate when all cables are attached Important notice This device is set to half duplex mode at the factory If you are experiencing excessive collision errors or CRC errors then you must force full duplex mode operation on ...

Страница 4: ...vironment up to 100m of CAT 5 UTP and 2km of multi mode fiber may be used Figure 3 MIL 185C UTP ACTIVE 5VDC FCC PART 15 CLASS A COMPLIANT RX TX ATM Twist Model MIL 185 UTP to Fiber ATM Multi Mode CONVERTER POWER FIBER ACTIVE UTP ACTIVE UTP ACTIVE 5VDC FCC PART 15 CLASS A COMPLIANT RX TX ATM Twist Model MIL 185 UTP to Fiber ATM Multi Mode CONVERTER POWER FIBER ACTIVE UTP ACTIVE Fiber cabling RJ 45 ...

Отзывы: