Quick   Setup   Guide   and   Warranty   Information   

The   RB750UP   is   a   router   with   five   Ethernet   ports.   It   has   one   USB   2.0   port,   and   supports   PoE   power   output   to      
ports   2-­‐5   (500mA   maximum   per   port).   

First   use   

 

Connect   your   WAN   cable   to   port   1,      
and   LAN   computers   to   ports   2-­‐5   

 

Set   LAN   computer   IP   configuration   to   automatic   (DHCP)   

 

RB750UP   Default   IP   address   from   LAN   is   192.168.88.1   

Powering   

The   board   accepts   powering   from   the   power   jack   or   from   the   
first   Ethernet   port   (Passive   PoE):   

 

direct-­‐input   power   jack   (5.5mm   outside   and   2mm   inside,   female,   pin   positive   plug)   accepts   8-­‐28V   DC   

 

first   Ethernet   port   accepts   passive   Power   over   Ethernet   accepts   8-­‐28V   DC   

Normally   the   power   consumption   of   this   device   is   2.4W,   under   maximum   load   -­‐   3.6W   

Power   output   

This   RouterBOARD   device   can   supply   PoE   powering   to   external   devices   from   its   Ethernet   ports.   This   is   convenient   as   
you   don't   need   any   additional   PoE   injectors   to   power   other   devices.   This   feature   is   indicated   by   the   letter   “P”   in   the   
device   model   name.   The   output   Voltage   will   be   the   same   as   input   Voltage,   and   this   feature   will   have   to   be   enabled   
on   the   specific   ports   in   RouterOS   software.   By   default   it   is   disabled.   Maximum   power   output   of   each   ethernet   port   in   
this   mode   is   500mA.   Once   Power   Output   is   enabled   in   RouterOS,   the   Ethernet   LED   light   turns   from   Green,   to   Red.   
Read   LED   means   the   port   is   currently   providing   PoE   power.      

Booting   process   

This   device   doesn't   come   fitted   with   a   Serial   Port   connector,   so   initial   connection   has   to   be   done   via   the   Ethernet   
cable,   using   the   MikroTik   Winbox   utility.   Winbox   should   be   used   to   connect   to   the   default   IP   address   of   

192.168.88.1   

with   the   username   

admin

   and   no   password.   

In   case   IP   connection   is   not   available,   Winbox   can   also   be   used   to   connect   to   the   MAC   address   of   the   device.   More   
information   here:   

http://wiki.mikrotik.com/wiki/First_time_startup

   

In   case   you   wish   to   boot   the   device   from   network,   for   example   to   use   MikroTik   Netinstall,   hold   the   RESET   button   of   
the   device   when   starting   it   until   the   LED   light   turns   off,   and   RB750   will   start   to   look   for   Netinstall   servers.   

Extension   Slots   and   Ports   

 

Five   individual   Ethernet   ports,   supporting   automatic   cross/straight   cable   correction   (Auto   MDI/X),   so   you   can   
use   either   straight   or   cross-­‐over   cables   for   connecting   to   other   network   devices.   The   Ethernet   port   accepts   
8-­‐28   V   DC   powering   from   a   passive   PoE   injector,   12V   or   more   is   recommended   to   compensate   for   loss   in   
cables.   