MIKRODEV XIO211-E0N-GD0-B2000 Скачать руководство пользователя страница 6

 


 

 

XIO211 EXTENSIONS FAMILY HARDWARE MANUAL 

 

WARNING!                                            

 

Please take care of the following issues when using Mikrodev devices. 

 

Since the unit operates with 24 VDC (12-36 VDC) voltage, you should take care of 

the voltage level that the unit is connected to. If a voltage above this voltage level 

is applied, the device may be damaged and may be out of warranty. 

 

Make sure that the energy connection of your device is connected to the ground or 

to a properly grounded terminal. 

 

Make  sure  that  the  environment  in  which  your  device  is  being  used  is  free  of 

moisture, electric shock, vibration and dust. 

 

Pay attention to the supply voltage and the connections of the product. Mikrodev is 

not responsible for any issues due to power failure since there is no auxiliary supply 

(UPS) on the device. 

 

The fuse to be used must be a FF super fast type and current limit value 1A. 

 

Do  not  use  the  device  under  conditions  other  than  the  environmental  conditions 

specified  in  the  "Electrical  Specifications"  section  (humidity,  dust,  liquid  and 

temperature, etc.) 

 

Removing the warranty label on the product or removing the protective case will void 

the warranty. 

 

Products  that  are  damaged,  boxes  have  been  changed  and  other  brand  labels  are 

affixed are not covered by the warranty. 

 

The appliance must not be cleaned with solvents (thinner, benzine, acid etc.) or with 

abrasive cleaning agents. 

 

Only dry cloth should be used when cleaning the appliance. 

 

Do not open the device by removing the case of the appliance, do not interfere with 

the electronic components and circuits. There is no user-replaceable part inside the 

device.  

 

If there is a problem or malfunction on your device, it should only be repaired by 

an  authorized  service.  Installation  and  electrical  connections  must  be  made  by 

technical personnel in accordance with the instructions in the operating manual. 

 

Failure to comply with these rules may result in death, serious injury or property 

damage 

 

Содержание XIO211-E0N-GD0-B2000

Страница 1: ...put XIO211 E0N GD5 B0000 8 Relay XIO211 E0N GD2 B0401 8 Analog Input 0 20 mA 0 10 V XIO211 E0N GD3 B0000 8 Analog Output 0 20 mA XIO211 E0N GD3 B0800 8 Analog Output 0 10 V XIO211 E0N GD9 B0000 4 Anal...

Страница 2: ...MODULES 14 3 1 GENERAL INFORMATION 14 3 2 CONNECTION DIAGRAMS 15 4 XIO211 RELAY EXPANSION MODULES 17 4 1 GENERAL INFORMATION 17 4 2 CONNECTION DIAGRAMS 18 5 XIO211 ANALOG INPUT EXPANSION MODULES 20 5...

Страница 3: ...m 16 Figure 13 GD5 Board Type Connector and Physical Interfaces 17 Figure 14 Relay Expansion Module Power Connection Diagram 18 Figure 15 Relay Output Expansion Module Connection Diagram 19 Figure 16...

Страница 4: ...GD8 B6000 8 Digital Input 8 Digital Output XIO211 E0N GD5 B0000 8 Relay XIO211 E0N GD2 B0401 8 Analog Input 0 20 mA 0 10 V XIO211 E0N GD3 B0000 8 Analog Output 0 20 mA XIO211 E0N GD3 B0800 8 Analog Ou...

Страница 5: ...ired by the industrial automation industry and the quality of our products are proved on the field for many years MIKRODEV is one of the few companies in the world that has its own designed IEC 61131...

Страница 6: ...not use the device under conditions other than the environmental conditions specified in the Electrical Specifications section humidity dust liquid and temperature etc Removing the warranty label on t...

Страница 7: ...n a lightly force is applied to the lower part the device locates into the DIN rail easily and the montage is completed See Figure 1 Figure 1 DIN Rail Mounting Expansion Installation Assembly between...

Страница 8: ...tor and Physical Interfaces 1 Device Power V Connection 2 Device Power V Connection 3 N A 4 Digital Input Ground Connection 5 Digital Input Connections 6 System Power LED 7 System Running LED 8 System...

Страница 9: ...l Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Swit...

Страница 10: ...XIO211 E0N GD0 B2000 Module Input 16 Channel PNP Module Input Range 0 50 VDC ON Voltage Range 9 50 VDC OFF Voltage Level 0 5 VDC Input Impedance 2M Isolation Optical OFF to ON Response 20 us ON to OFF...

Страница 11: ...terfaces 1 Device Power V Connection 2 Device Power V Connection 3 Digital Output Ground Connection 4 Digital Output Supply Connection 5 Digital Output Connections 6 N A 7 System Power LED 8 System Ru...

Страница 12: ...nection 2 Device Power V Connection 3 Digital Output Ground Connection 4 Digital Output Supply Connection 5 Digital Output Connections 6 System Power LED 7 System Running LED 8 System Error LED 9 CANB...

Страница 13: ...l Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Swit...

Страница 14: ...11 E0N GD1 B4000 Module Output 8 Channel Mosfet Output 16 Channel Mosfet Output Module Output Type PNP Transistor Module Output Range 12 36 VDC Module Output Current 2 A 30 VDC Module Output GND Commo...

Страница 15: ...Power V Connection 2 Device Power V Connection 3 Digital Output Supply Connection 4 Digital Input Output Ground Connection 5 Digital Input Connections 6 Digital Output Connections 7 System Power LED...

Страница 16: ...ver Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Switch...

Страница 17: ...VDC OFF Voltage Level 0 5 VDC Input Impedance 2M Isolation Optical OFF to ON Response 20 us ON to OFF Response 90 us Module Output 8 Channel Mosfet Output Module Output Type PNP Transistor Module Outp...

Страница 18: ...Physical Interfaces 1 Device Power V Connection 2 Device Power V Connection 3 N A 4 Relay NO Normally Open Contact 5 Relay COM Common Contact 6 System Power LED 7 System Running LED 8 System Error LED...

Страница 19: ...ional Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary...

Страница 20: ...4 2 2 Relay Outputs Order Code XIO211 E0N GD5 B0000 Relay Output 8 Channel Relay Contact Output COM NO Normally Open Relay Contact Max Current Value 5A 250V AC 3A 30V DC Isolation Dry Contact Figure 1...

Страница 21: ...ctor and Physical Interfaces 1 Device Power V Connection 2 Device Power V Connection 3 N A 4 Analog Input Ground Connection 5 Analog Input Connections 6 System Power LED 7 System Running LED 8 System...

Страница 22: ...al Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Swi...

Страница 23: ...Type Current or Voltage Analog Input 8 Channel Resolution 16 Bit Analog Input Accuracy 1 Accuracy Current Input Range 0 20 mA 4 20 mA Voltage Input Range 0 10 V Analog Input GND Common 1 GND 8 Point...

Страница 24: ...tor and Physical Interfaces 1 Device Power V Connection 2 Device Power V Connection 3 N A 4 Analog Output Ground Connection 5 Analog Output Connections 6 System Power LED 7 System Running LED 8 System...

Страница 25: ...l Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Swit...

Страница 26: ...ule Output Type Current Voltage Analog Output 8 Channel Resolution 12 Bit Analog Output Accuracy 1 Accuracy Current Output Range 0 20 mA 4 20 mA Voltage Output Range 0 10 V Analog Output GND Common 8...

Страница 27: ...erfaces 1 Device Power V Connection 2 Device Power V Connection 3 N A 4 Analog Input Output Ground Connection 5 Analog Input Connections 6 Analog Output Connections 7 System Power LED 8 System Running...

Страница 28: ...ver Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Switch...

Страница 29: ...urrent Input Range 0 20 mA 4 20 mA Voltage Input Range 0 10 V Analog Input GND Common 1 GND 4 Point Common Isolation Optical Isolation Expansion Bus Analog Output 4 Channel Resolution 12 Bit Analog Ou...

Страница 30: ...ice Power V Connection 2 Device Power V Connection 3 RTD Excitation Current Output 2 wire connection jumper is thrown between signal inputs 4 RTD Input Connections 5 RTD Input Ground Connections 6 Sys...

Страница 31: ...nal Over Expansion Bus Power 13W Power Protection Yes Enviromental Conditions Operating Temperature 20 60 C Storage Temperature 40 85 C Humidity 5 95 RH Operating Altitude 0 2000 m ID Assign Rotary Sw...

Страница 32: ...211 E0N GD4 B0000 XIO211 E0N GD4 B0010 RTD Input Type PT1000 PT100 RTD Input 6 Channel RTD Input Resolution 12 Bit RTD Input Accuracy 1 Accuracy RTD Input GND Connection 6 GND 6 Point Common Temperatu...