Migatronic PI 200 DC Скачать руководство пользователя страница 8

 

20

Fast pulse 

Is used for selection of fast pulse. 
The pulse current is equal to the 

set current. It is possible to adjust: 

 

Pulse frequency 

 

Variable 25 - 523 Hz. 

 

Base amp 

Adjustable from 10 to 90% of the pulse current. 

 

Synergy PLUS 

TM 

(TIG DC) 

The machines automatically and dynamically 
adjust all overall pulse parameters during 

welding, when the peak welding current has been set 
by encoder. 
 

TIG tack welding TIG-A-TACK 

TM

 

The machine offers one tack welding program 
to allow a quick switch from welding to tack 

welding. The following features will be available: 

-

 

Arc ignition HF 2-times 

-

 No 

slope-up/slope-down 

-

 No 

pulse 

-

  Spot TIME from 0.01 to 2.5 secs in steps of 0.01 

sec. Set the value by selecting the parameter 
“spot time” 

.

 

 

Electrode welding (MMA) 

Is used for selection of electrode 
welding. It is not possible to 

change welding process during welding. 
 

Hot start 

Hot start is a function that helps to establish 
the arc at the beginning of MMA welding. This 

can be achieved by increasing welding current (when 
the electrode is applied to the workpiece) in relation to 
the set value. This increased start amp is maintained 
for half a second, after which it decreases to the set 
value of welding current. 
 

Set welding
current

Welding
start

0,5 s

Additional
current supply
from hot-start-
function

time

Amp

 

 
The hot start value reflects the percentage value by 
which initial current is increased, and can be set be-
tween 0% and 100%. 

 

Arc-power  

 The arc power function is used to stabilise the 
arc in MMA welding. This can be acheived by 

increasing welding current during the short-circuits. 
The additional current ceases when the short circuit is 
no longer present. 

Set welding
current

short-
circuit

Additional current
supply from the arc
power function

time

Amp

 

 
Arc power can be adjusted between 0 and 100% of 
the welding current setting. 
E.g.  If the welding current is set to 40A and arc 

power to 50% the additional current is 20 A 
equals 60 A when doing arc power. If the arc 
power is set to 100% the additional current is 40 
A equals 80 A when doing arc power. 

 

Torch adjustment / 
remote control – 7-poled plug 

The regulation of welding current is made by 

means of the torch potentiometer (optional). The 
maximum current reachable is the level previously 
adjusted on the front panel. The minimum current is 
5A. 
 

External adjustment – 
8-poled plug (optional) 

Can be used for foot pedal (optional) and 

remote control units (optional) that use a 8-poled plug. 
The function is used for arc ignition and adjustment of 
the current. The maximum current reachable is the 
level previously adjusted on the front panel. The actual 
current is shown on the display. 
Start amp can be used as a setting of minimum 
current as a percentage of maximum current.  

Please note: The machine will automatically start in two-times in this 
function when the machine uses a software version before 1.12.

 

 

Ignition methods 

It is possible to choose between 2 different 
methods of ignition for TIG welding: High-

Frequency (HF) and LIFTIG ignition. The ignition 
method cannot be changed during welding. The 
LIFTIG ignition is active when the indicator is 
illuminated. The HF is automatically active when the 
LED is switched off. 

HF-ignition 

In HF-TIG ignition the TIG arc is ignited without 
contact. A high-frequency (HF) impulse initiates the 
arc when the torch trigger is activated. 
The HF will not arise and the machine will stop if the 
electrode is in contact with the workpiece. Detach the 
electrode and start again. 

LIFTIG-ignition 

In LIFTIG ignition the TIG arc is ignited after making 
contact between the workpiece and the tungsten 
electrode, after which the trigger is activated and the 
arc is established by lifting the electrode from the 
workpiece. 

Содержание PI 200 DC

Страница 1: ...ing Instruction manual Betriebsanleitung Manuel d instruction Manuale d istruzione Bruksanvisning Käyttöohje Manual de instrucciones Gebruikershandleiding Manual de instruções Podręcznik obsługi Valid from 2012 week 09 50113201 R ...

Страница 2: ...by declare that our machine as stated below Type PI 200 250 DC HP As of Week 44 2005 conforms to directives 2006 95 EC and 2004 108 EC European Standards EN IEC60974 1 EN IEC60974 2 EN IEC60974 3 EN IEC60974 10 Class A Issued in Fjerritslev on 1st November 2005 Peter Roed Managing director ...

Страница 3: ...wing Electricity The welding equipment must be installed according to safety regulations and by a properly trained and qualified person The machine must be connected to earth through the mains cable Make sure that the welding equipment is correctly maintained In the case of damaged cables or insulation work must be stopped immediately in order to carry out repairs Repairs and maintenance of the eq...

Страница 4: ...s of the breaker 3 on the rear of the machine Lifting instructions The lifting point must be used as shown in the following drawing The machine must not be lifted with a mounted gas bottle Configuration MIGATRONIC disclaims all responsibility for damaged cables and other damages related to welding with undersized welding torches and welding cables measured by welding specifications e g in relation...

Страница 5: ... MMA The electrode holder and return current cable are connected to plus tap 5 and minus tap 4 Observe the instructions from the electrode supplier when selecting polarity Connection of foot control Foot control is connected to the 7 poled plug 7 or through the 8 poled plug 15 depending on the foot control type Connection of remote control PI machines equipped with 8 pole control interface 15 can ...

Страница 6: ...eep pressed the knob after 3 sec the display will start flashing to indicate the current program has been restored to Factory settings The latest used program setting in the relevant program group MMA DC and TIG DC will be shown when the program key pad is selected Welding current The key pad can be used to display the welding current Adjustable from 5A to 200A or 250A depending on the machine mod...

Страница 7: ...achine enters a slope down stage During this stage current is reduced from welding current to Final Amp over a period of time called the slope down time and variable 0 20 sec in steps of 0 1 sec Final Amp A The slope down stage is completed when the current level has fallen to the value stated in the Final Amp parameter In 4 times it is possible to continue in Final Amp mode until the trigger is r...

Страница 8: ...mp Arc power can be adjusted between 0 and 100 of the welding current setting E g If the welding current is set to 40A and arc power to 50 the additional current is 20 A equals 60 A when doing arc power If the arc power is set to 100 the additional current is 40 A equals 80 A when doing arc power Torch adjustment remote control 7 poled plug The regulation of welding current is made by means of the...

Страница 9: ...ti freeze control The anti freeze control reduces the current when the electrodes stick to the weld piece This makes it easier to break off the electrode and welding can continue Reset It is possible to recall all factory standard parameters In this case all programs in the machine will be reset to the following value MMA current 80A TIG Current 80A TIG Spot Current 80A Pre flow 0 0 sec Post flow ...

Страница 10: ...ting the encoder for locked parameters the display will flash PG L to remember the active protection 0 unlocked default setting 1 locked Panel LOCK Complete lock of box All keypads and Encoder are disabled When pressing locked key pads or rotating the encoder the display will flash PA L to remember the active protection 0 unlocked default setting 1 locked 4 times option for torch trigger Permit to...

Страница 11: ...0 01 10 secs Pause time TIG MMA 0 01 10 secs Base Amp TIG MMA 10 90 Second current Bilevel TIG 10 200 TIG ignition TIG HF LIFTIG Triggerfunction TIG 2 4 stroke 1 S The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock 2 Equipment marked IP23 is designed for indoor and outdoor applications MAINTENANCE The machine requires ...

Страница 12: ...t made the standard warranty period is twelve months for new welding machines as from the date of invoicing to end user The original invoice is documentation for the warranty period Migatronic provides warranty according to the warranty conditions in force through remedying defects in the welding machines that can be proved to be caused by improper materials or workmanship in the warranty period A...