Migatronic PI 200 DC Скачать руководство пользователя страница 7

 

19

TIG welding 

 

 

 

 TIG welding 

The parameters can be adjusted with the 
control knob after they are shown on the 

display. Press the relative key to select the parameter. 
The relevant LED will illuminate. 
 

Pre-flow [s] 

Pre-flow is the period of time for which gas 
flows after the torch switch is pressed and 

before the HF arc is established, or until the torch is 
lifted away from the workpiece in the LIFTIG process. 
Variable 0-10 sec. 
 

Start Amp  [A%] 

Immediately after the arc has been 
established, the machine regulates the 

welding current to the value stated in the Start Amp 
parameter. Start Amp is set as a percentage of the 
required welding current and is variable between 1-
200% of the welding current. Please note that values 
higher than 100% generate a Start Amp bigger than 
welding current. 
 

Slope-up [s] 

Once the arc has been established, the 
welding process enters a slope-up stage 

during which the welding current is increased in linear 
fashion from the value stated in the Start Amp para-
meter to the required welding current. The duration of 
this slope-up time is variable 0-20 sec in steps of 0.1 
sec. 
 

Second current level 

Adjustable from 10 to 200% of welding 
current. It is activated in four-times only by 

pressing and releasing quickly the torch trigger. 
Please note that values bigger than 100% generate a 
second current bigger than welding current. 
 

Slope-down [s] 

When welding has stopped by activating the 
trigger, the machine enters a slope-down 

stage. During this stage current is reduced from 
welding current to Final Amp over a period of time 
called the slope-down time and variable 0-20 sec in 
steps of 0.1 sec. 

Final Amp [A%] 

The slope-down stage is completed when 
the current level has fallen to the value 

stated in the Final Amp parameter. In 4-times it is 
possible to continue in Final Amp mode until the 
trigger is released. Final Amp is stated as a 
percentage of the required welding current and is 
variable between 1 - 90% of the welding current. 
 

Post-flow [s]

 

Post-flow is the period of time for which gas 
flows after the arc is extinguished and is 

variable 0-20 sec. 
 

Spot time 

The spot time in TIG is the time from the end 
of slope up to beginning of slope down. 

Therefore, during spot time the machine is welding 
with the adjusted current. The LED flashes on and off 
when the function is active. 
 

Set welding
current

slope-up

spot
welding time

slope-down

time

Amp

trig down (  ) / up (  )

 

 
Set the timer before igniting the arc. The torch trigger, 
depending from the selected torch mode can interrupt 
the spot welding time. Variable 0,01-20sec: steps of 
10msec up to 0,5sec, over in steps of 0,1sec. The 
function is disconnected when the time is set to 0 sec. 
When used during tack welding, the timer can be set 
from 0.01 sec to 2.5 secs (See TIG-A-TACK). 
 

Slow pulse 

Is used for selection of slow pulse. 
The pulse current is equal to the 

set current. It is possible to adjust: 
 

Pulse time 

Adjustable from 0.01 to 10 sec. in steps of 
0.01 sec. 
 

Pause time 

Adjustable from 0.01 to 10 sec. in steps of 
0.01 sec. 

 

Base amp 

Adjustable from 10 to 90% of the pulse 
current. 

Содержание PI 200 DC

Страница 1: ...ing Instruction manual Betriebsanleitung Manuel d instruction Manuale d istruzione Bruksanvisning Käyttöohje Manual de instrucciones Gebruikershandleiding Manual de instruções Podręcznik obsługi Valid from 2012 week 09 50113201 R ...

Страница 2: ...by declare that our machine as stated below Type PI 200 250 DC HP As of Week 44 2005 conforms to directives 2006 95 EC and 2004 108 EC European Standards EN IEC60974 1 EN IEC60974 2 EN IEC60974 3 EN IEC60974 10 Class A Issued in Fjerritslev on 1st November 2005 Peter Roed Managing director ...

Страница 3: ...wing Electricity The welding equipment must be installed according to safety regulations and by a properly trained and qualified person The machine must be connected to earth through the mains cable Make sure that the welding equipment is correctly maintained In the case of damaged cables or insulation work must be stopped immediately in order to carry out repairs Repairs and maintenance of the eq...

Страница 4: ...s of the breaker 3 on the rear of the machine Lifting instructions The lifting point must be used as shown in the following drawing The machine must not be lifted with a mounted gas bottle Configuration MIGATRONIC disclaims all responsibility for damaged cables and other damages related to welding with undersized welding torches and welding cables measured by welding specifications e g in relation...

Страница 5: ... MMA The electrode holder and return current cable are connected to plus tap 5 and minus tap 4 Observe the instructions from the electrode supplier when selecting polarity Connection of foot control Foot control is connected to the 7 poled plug 7 or through the 8 poled plug 15 depending on the foot control type Connection of remote control PI machines equipped with 8 pole control interface 15 can ...

Страница 6: ...eep pressed the knob after 3 sec the display will start flashing to indicate the current program has been restored to Factory settings The latest used program setting in the relevant program group MMA DC and TIG DC will be shown when the program key pad is selected Welding current The key pad can be used to display the welding current Adjustable from 5A to 200A or 250A depending on the machine mod...

Страница 7: ...achine enters a slope down stage During this stage current is reduced from welding current to Final Amp over a period of time called the slope down time and variable 0 20 sec in steps of 0 1 sec Final Amp A The slope down stage is completed when the current level has fallen to the value stated in the Final Amp parameter In 4 times it is possible to continue in Final Amp mode until the trigger is r...

Страница 8: ...mp Arc power can be adjusted between 0 and 100 of the welding current setting E g If the welding current is set to 40A and arc power to 50 the additional current is 20 A equals 60 A when doing arc power If the arc power is set to 100 the additional current is 40 A equals 80 A when doing arc power Torch adjustment remote control 7 poled plug The regulation of welding current is made by means of the...

Страница 9: ...ti freeze control The anti freeze control reduces the current when the electrodes stick to the weld piece This makes it easier to break off the electrode and welding can continue Reset It is possible to recall all factory standard parameters In this case all programs in the machine will be reset to the following value MMA current 80A TIG Current 80A TIG Spot Current 80A Pre flow 0 0 sec Post flow ...

Страница 10: ...ting the encoder for locked parameters the display will flash PG L to remember the active protection 0 unlocked default setting 1 locked Panel LOCK Complete lock of box All keypads and Encoder are disabled When pressing locked key pads or rotating the encoder the display will flash PA L to remember the active protection 0 unlocked default setting 1 locked 4 times option for torch trigger Permit to...

Страница 11: ...0 01 10 secs Pause time TIG MMA 0 01 10 secs Base Amp TIG MMA 10 90 Second current Bilevel TIG 10 200 TIG ignition TIG HF LIFTIG Triggerfunction TIG 2 4 stroke 1 S The machine meets the standards which are demanded of machines working in areas where there is an increased risk of electric shock 2 Equipment marked IP23 is designed for indoor and outdoor applications MAINTENANCE The machine requires ...

Страница 12: ...t made the standard warranty period is twelve months for new welding machines as from the date of invoicing to end user The original invoice is documentation for the warranty period Migatronic provides warranty according to the warranty conditions in force through remedying defects in the welding machines that can be proved to be caused by improper materials or workmanship in the warranty period A...