Areas of application
46
After reprocessing
The load carriers and load items may be very hot directly after repro-
cessing. The load carriers and load items must be allowed to cool
down before removal.
Curved hollow parts of the load items may contain residual water that
could be spilt when the inserts are removed.
Risk of slipping due to spilt residual water.
Depending on the surface and footwear, spilt residual water can
pose a slipping risk.
Carefully wipe up spilt residual water before removing the load
items from the inserts.
Air regulators
Check whether the medium-pressure hoses have disconnected
from the quick-release couplings and whether the compressed air
indicator is still showing sufficient pressure in the pressure cham-
ber.
If the air regulators have disconnected from the quick-release coup-
lings or there is not enough pressure in the pressure chamber, the air
regulators must be cleaned and dried internally in line with the manu-
facturer’s instructions before further use.
Release the medium-pressure hoses by pulling back the collars on
the quick-release couplings.
Remove the air regulators and empty any remaining water into the
wash cabinet or an on-site slops basin before removing items.
Follow the air regulator manufacturer’s instructions regarding dry-
ing, assembly and replacing wear parts.
Before using the air regulators again following reprocessing, a func-
tion check must be carried out in line with the manufacturer’s in-
structions.